MemoPart™ Ventricular Septal Defect (VSD) Occluder
MemoPart™
Fit to the clinic, long-term safety
MemoPart™ VSD OccluderDetail
Product Description
MemoPart™ Ventricular Septal Defect (VSD) Occluder is a self-expanding double-disc nitinol mesh occlusion device.The 2 discs are connected by a short waist which corresponds to the defect size. Polyester fabric is securely sewnto each disc to secure the occlusion. The device is visible under X-ray.
Indications for Use
Membranous VSD Occluder
The MemoPartTM Membranous VSD Occluder is used for minimally invasive transcatheter closure of perimembranous ventricular septal defects.
Muscular VSD Occluder
The MemoPartTM Muscular VSD Occluder is indicated for use in patients with a complex ventricular septal defect (VSD) of significant size to warrant closure (large volume left-to-right shunt, pulmonary hypertension,and/or clinical symptoms ofcongestive heart failure) who are considered to be at high risk for standard transatrial or transarterial surgical closure based on anatomical conditions and/or based on overall medical condition.
Ordering Information
MuscularVentricular Septal Defect (VSD)Occluder
|
Catalogue No |
Device Size |
A Waist Diameter (mm) |
BLV DiscDiameter(mm) |
C RV Disc Diameter (mm) |
H Waist Length (mm) |
|
SQFDQ- Ⅰ a04 |
4 |
4 |
8 |
8 |
|
|
SQFDQ- Ⅰ a05 |
5 |
5 |
9 |
9 |
|
|
SQFDQ- Ⅰ a06 |
6 |
6 |
10 |
10 |
|
|
SQFDQ- Ⅰ a07 |
7 |
7 |
11 |
11 |
|
|
SQFDQ- Ⅰ a08 |
8 |
8 |
12 |
12 |
|
|
SQFDQ- Ⅰ a09 |
9 |
9 |
13 |
13 |
|
|
SQFDQ- Ⅰ a10 |
10 |
10 |
14 |
14 |
|
|
SQFDQ- Ⅰ a12 |
12 |
12 |
16 |
16 |
|
|
SQFDQ- Ⅰ a14 |
14 |
14 |
18 |
18 |
|
|
SQFDQ- Ⅰ a16 |
16 |
16 |
20 |
20 |
|
|
SQFDQ- Ⅰ a18 |
18 |
18 |
22 |
22 |
|
|
SQFDQ- Ⅰ b04 |
4 |
4 |
10 |
8 |
|
|
SQFDQ- Ⅰ b05 |
5 |
5 |
11 |
9 |
|
|
SQFDQ- Ⅰ b06 |
6 |
6 |
12 |
10 |
|
|
SQFDQ- Ⅰ b07 |
7 |
7 |
13 |
11 |
|
|
SQFDQ- Ⅰ b08 |
8 |
8 |
14 |
12 |
|
|
SQFDQ- Ⅰ b09 |
9 |
9 |
15 |
13 |
|
|
SQFDQ- Ⅰ b10 |
10 |
10 |
16 |
14 |
|
|
SQFDQ- Ⅰ b12 |
12 |
12 |
18 |
16 |
|
|
SQFDQ- Ⅰ b14 |
14 |
14 |
20 |
18 |
|
|
SQFDQ- Ⅰ b16 |
16 |
16 |
22 |
20 |
|
|
SQFDQ- Ⅰ b18 |
18 |
18 |
24 |
22 |
|
|
SQFDQ- Ⅰ c04 |
4 |
4 |
14 |
10 |
10 |
|
SQFDQ- Ⅰ c05 |
5 |
5 |
15 |
11 |
10 |
|
SQFDQ- Ⅰ c06 |
6 |
6 |
16 |
12 |
10 |
|
SQFDQ- Ⅰ c07 |
7 |
7 |
17 |
13 |
10 |
|
SQFDQ- Ⅰ c08 |
8 |
8 |
18 |
14 |
10 |
|
SQFDQ- Ⅰ c09 |
9 |
9 |
19 |
15 |
10 |
|
SQFDQ- Ⅰ c10 |
10 |
10 |
20 |
16 |
10 |
|
SQFDQ- Ⅰ c12 |
12 |
12 |
22 |
18 |
10 |
|
SQFDQ- Ⅰ c14 |
14 |
14 |
24 |
20 |
10 |
|
SQFDQ- Ⅰ c16 |
16 |
16 |
26 |
22 |
10 |
|
SQFDQ- Ⅰ c18 |
18 |
18 |
28 |
24 |
10 |
Hubless MuscularVentricular Septal Defect (VSD)Occluder
|
Catalogue No |
Device Size |
A Waist Diameter (mm) |
BLV DiscDiameter(mm) |
C RV Disc Diameter (mm) |
H Waist Length (mm) |
|
WTSQFDQ- Ⅰ a04 |
4 |
4 |
8 |
8 |
5 |
|
WTSQFDQ- Ⅰ a05 |
5 |
5 |
9 |
9 |
5 |
|
WTSQFDQ- Ⅰ a06 |
6 |
6 |
10 |
10 |
5 |
|
WTSQFDQ- Ⅰ a07 |
7 |
7 |
11 |
11 |
5 |
|
WTSQFDQ- Ⅰ a08 |
8 |
8 |
12 |
12 |
5 |
|
WTSQFDQ- Ⅰ a09 |
9 |
9 |
13 |
13 |
5 |
|
WTSQFDQ- Ⅰ a10 |
10 |
10 |
14 |
14 |
5 |
|
WTSQFDQ- Ⅰ a12 |
12 |
12 |
16 |
16 |
5 |
|
WTSQFDQ- Ⅰ a14 |
14 |
14 |
18 |
18 |
5 |
|
WTSQFDQ- Ⅰ a16 |
16 |
16 |
20 |
20 |
5 |
|
WTSQFDQ- Ⅰ a18 |
18 |
18 |
22 |
22 |
5 |
|
WTSQFDQ- Ⅰ b04 |
4 |
4 |
10 |
8 |
7 |
|
WTSQFDQ- Ⅰ b05 |
5 |
5 |
11 |
9 |
7 |
|
WTSQFDQ- Ⅰ b06 |
6 |
6 |
12 |
10 |
7 |
|
WTSQFDQ- Ⅰ b07 |
7 |
7 |
13 |
11 |
7 |
|
WTSQFDQ- Ⅰ b08 |
8 |
8 |
14 |
12 |
7 |
|
WTSQFDQ- Ⅰ b09 |
9 |
9 |
15 |
13 |
7 |
|
WTSQFDQ- Ⅰ b10 |
10 |
10 |
16 |
14 |
7 |
|
WTSQFDQ- Ⅰ b12 |
12 |
12 |
18 |
16 |
7 |
|
WTSQFDQ- Ⅰ b14 |
14 |
14 |
20 |
18 |
7 |
|
WTSQFDQ- Ⅰ b16 |
16 |
16 |
22 |
20 |
7 |
|
WTSQFDQ- Ⅰ b18 |
18 |
18 |
24 |
22 |
7 |
|
WTSQFDQ- Ⅰ c04 |
4 |
4 |
14 |
10 |
10 |
|
WTSQFDQ- Ⅰ c05 |
5 |
5 |
15 |
11 |
10 |
|
WTSQFDQ- Ⅰ c06 |
6 |
6 |
16 |
12 |
10 |
|
WTSQFDQ- Ⅰ c07 |
7 |
7 |
17 |
13 |
10 |
|
WTSQFDQ- Ⅰ c08 |
8 |
8 |
18 |
14 |
10 |
|
WTSQFDQ- Ⅰ c09 |
9 |
9 |
19 |
15 |
10 |
|
WTSQFDQ- Ⅰ c10 |
10 |
10 |
20 |
16 |
10 |
|
WTSQFDQ- Ⅰ c12 |
12 |
12 |
22 |
18 |
10 |
|
WTSQFDQ- Ⅰ c14 |
14 |
14 |
24 |
20 |
10 |
|
WTSQFDQ- Ⅰ c16 |
16 |
16 |
26 |
22 |
10 |
|
WTSQFDQ- Ⅰ c18 |
18 |
18 |
28 |
24 |
10 |
Membranous SymmetricVentricular Septal Defect (VSD)Occluder
|
Catalogue No. |
Device Size |
AWaistDiameter(mm) |
BLV DiscDiameter(mm) |
C RV Disc Diameter (mm) |
HWaistLength(mm) |
|
SQFDQ- Ⅱ b04 |
04 |
4 |
8 |
8 |
|
|
SQFDQ- Ⅱ b05 |
05 |
5 |
9 |
9 |
|
|
SQFDQ- Ⅱ b06 |
06 |
6 |
10 |
10 |
|
|
SQFDQ- Ⅱ b07 |
07 |
7 |
11 |
11 |
|
|
SQFDQ- Ⅱ b08 |
08 |
8 |
12 |
12 |
|
|
SQFDQ- Ⅱ b09 |
09 |
9 |
13 |
13 |
|
|
SQFDQ- Ⅱ b10 |
10 |
10 |
14 |
14 |
|
|
SQFDQ- Ⅱ b12 |
12 |
12 |
16 |
15 |
|
|
SQFDQ- Ⅱ b14 |
14 |
14 |
18 |
17 |
|
|
SQFDQ- Ⅱ b16 |
16 |
16 |
22 |
20 |
|
|
SQFDQ- Ⅱ b18 |
18 |
18 |
24 |
22 |
|
|
SQFDQ- Ⅱ b20 |
20 |
20 |
26 |
24 |
Hubless Membranous SymmetricVentricular Septal Defect (VSD)Occluder
|
Catalogue No. |
Device Size |
AWaistDiameter(mm) |
BLV DiscDiameter(mm) |
C RV Disc Diameter (mm) |
HWaistLength(mm) |
|
WTSQFDQ- Ⅱ b04 |
04 |
4 |
8 |
8 |
|
|
WTSQFDQ- Ⅱ b05 |
05 |
5 |
9 |
9 |
|
|
WTSQFDQ- Ⅱ b06 |
06 |
6 |
10 |
10 |
|
|
WTSQFDQ- Ⅱ b07 |
07 |
7 |
11 |
11 |
|
|
WTSQFDQ- Ⅱ b08 |
08 |
8 |
12 |
12 |
|
|
WTSQFDQ- Ⅱ b09 |
09 |
9 |
13 |
13 |
|
|
WTSQFDQ- Ⅱ b10 |
10 |
10 |
14 |
14 |
|
|
WTSQFDQ- Ⅱ b12 |
12 |
12 |
16 |
15 |
|
|
WTSQFDQ- Ⅱ b14 |
14 |
14 |
18 |
17 |
|
|
WTSQFDQ- Ⅱ b16 |
16 |
16 |
22 |
20 |
|
|
WTSQFDQ- Ⅱ b18 |
18 |
18 |
24 |
22 |
|
|
WTSQFDQ- Ⅱ b20 |
20 |
20 |
26 |
24 |
Membranous AsymmetricVentricular Septal Defect (VSD)Occluder for Multi-Fenestrated Defects
|
Catalogue No |
Device Size |
A Waist Diameter (mm) |
B LV Disc Diameter (mm) |
C RV Disc Diameter (mm) |
H Waist Length (mm) |
|
SQFDQ- Ⅲ 04 |
04 |
4 |
12 |
8 |
|
|
SQFDQ- Ⅲ 05 |
05 |
5 |
13 |
9 |
|
|
SQFDQ- Ⅲ 06 |
06 |
6 |
14 |
10 |
|
|
SQFDQ- Ⅲ 07 |
07 |
7 |
15 |
11 |
|
|
SQFDQ- Ⅲ 08 |
08 |
8 |
16 |
12 |
|
|
SQFDQ- Ⅲ 09 |
09 |
9 |
17 |
13 |
|
|
SQFDQ- Ⅲ 10 |
10 |
10 |
18 |
14 |
|
|
SQFDQ- Ⅲ 12 |
12 |
12 |
20 |
16 |
|
|
SQFDQ- Ⅲ 14 |
14 |
14 |
22 |
18 |
|
|
SQFDQ- Ⅲ 16 |
16 |
16 |
24 |
20 |
|
|
SQFDQ- Ⅲ 18 |
18 |
18 |
26 |
22 |
Hubless Membranous AsymmetricVentricular Septal Defect (VSD)Occluder for Multi-Fenestrated Defects
|
Catalogue No |
Device Size |
A Waist Diameter (mm) |
B LV Disc Diameter (mm) |
C RV Disc Diameter (mm) |
H Waist Length (mm) |
|
WTSQFDQ- Ⅲ 04 |
04 |
4 |
12 |
8 |
|
|
WTSQFDQ- Ⅲ 05 |
05 |
5 |
13 |
9 |
|
|
WTSQFDQ- Ⅲ 06 |
06 |
6 |
14 |
10 |
|
|
WTSQFDQ- Ⅲ 07 |
07 |
7 |
15 |
11 |
|
|
WTSQFDQ- Ⅲ 08 |
08 |
8 |
16 |
12 |
|
|
WTSQFDQ- Ⅲ 09 |
09 |
9 |
17 |
13 |
|
|
WTSQFDQ- Ⅲ 10 |
10 |
10 |
18 |
14 |
|
|
WTSQFDQ- Ⅲ 12 |
12 |
12 |
20 |
16 |
|
|
WTSQFDQ- Ⅲ 14 |
14 |
14 |
22 |
18 |
|
|
WTSQFDQ- Ⅲ 16 |
16 |
16 |
24 |
20 |
|
|
WTSQFDQ- Ⅲ 18 |
18 |
18 |
26 |
22 |
Zero Rim EccentricVentricular Septal Defect (VSD) Occluderfor the Defect Close to Aortic Valve
|
Catalogue No |
Device Size |
A Waist Diameter (mm) |
B LV Disc Diameter (mm) |
C RV Disc Diameter (mm) |
H Waist Length (mm) |
|
SQFDQ- Ⅳ04 |
04 |
4 |
9 |
8 |
|
|
SQFDQ- Ⅳ 05 |
05 |
5 |
10 |
9 |
|
|
SQFDQ- Ⅳ 06 |
06 |
6 |
11 |
10 |
|
|
SQFDQ- Ⅳ 07 |
07 |
7 |
12 |
11 |
|
|
SQFDQ- Ⅳ 08 |
08 |
8 |
13 |
12 |
|
|
SQFDQ- Ⅳ 09 |
09 |
9 |
14 |
13 |
|
|
SQFDQ- Ⅳ 10 |
10 |
10 |
17 |
15 |
|
|
SQFDQ- Ⅳ 12 |
12 |
12 |
20 |
18 |
|
|
SQFDQ- Ⅳ 14 |
14 |
14 |
22 |
20 |
|
|
SQFDQ- Ⅳ 16 |
16 |
16 |
24 |
22 |
To build LepuMedical into a large-scale global company in the cardiovascular industry that provides products and solutions covering prevention, treatment and rehabilitation for the patients with cardiovascular and related diseases.
If you want to know more kinds of medical devices china, please visit our website.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Angioway™ Manifolds | Angioway™ Medical ManifoldsDetail Visible handle makes the flow control easy and accurate On / Off types are available for different user h... | |
| Disposable Endo Retrieval Bag | Disposable Endo Retrieval Bag Application: Suitable for minimally invasive surgery to remove the excisional diseased tissue from the body. Typ... | |
| Molecular Diagnostics | Types of Molecular Diagnostics Fully Automated Nucleic Acid Extractor We offer a wide range of Fully Automated Nucleic Acid Extractors with hig... | |
| GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System | To develop LepuMedical into one of the largest cardiovascular products manufacturersand on the platforms of medical device, medicine, healthcare pr... | |
| Eel Cath™ Electrophysiology Ablation Catheter | Eel Cath™ Electrophysiology Ablation Catheter are used for interventional treatment of tachyarrhythmia with radiofrequency ablation of the he... |
Похожие товары
| CHISON SonoBook 6 Portable Ultrasound | Продавец: CHISON Medical Technologies Co., Ltd | Featured with compact laptop based design for easy mobility, provide solutions when fast reaction... | |
| Portable Ultrasound Machine SonoAir 70 | Продавец: CHISON Medical Technologies Co., Ltd | Specifications ·LatestAIRplatform ·2.1 kgUltra-lightweight(with battery) ·... | |
| XBit 90 Ultrasound | Продавец: CHISON Medical Technologies Co., Ltd | Premium Cartbased Ultrasound SystemSpecifications ·Latest NIT platform ·Verstile ... | |
| SonoMax 7 ultrasound | Продавец: CHISON Medical Technologies Co., Ltd | CHISON's new innovativeultrasound machine SonoMax 7, specialized for healthcare professionals, pr... | |
| SonoPort Portable Cart-based Ultrasound | Продавец: CHISON Medical Technologies Co., Ltd | SonoPort Portable Cart-based Ultrasound Product Description Ultrasound with imaging capabilitie... |













