LM-79 Moving Detector Type C Goniophotometer
LSG-6000 Moving DetectorGoniophotometer(Mirror Type C) was manufactured by LISUN completely meetsLM-79-19,IES LM-80-08,COMMISSION DELEGATED REGULATION (EU) 2019/2015,CIE-121, CIE S025,SASO 2902, IS16106 andEN13032-1clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG-5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m.
What is the use of goniophotometer?
LSG-6000 gonio photometermanufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Measurement:
Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc.
Features:
• The near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously.
• The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares.
• The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop.
• The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards.
• Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately.
Specifications:
• The luminaire under test rotates around the mirror with an angle of (γ) vertical axis ±180° (or 0-360°) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180° (or 0-360° ).
• The accuracy of angle: 0.05°, Resolution of angle: 0.001°
• Accuracy of Goniophotometrydetector: Constant temperaturephoto detectorDIN5032-6/CIE pub1. No. 69 Class L
• LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux.
• Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11
• LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system "Goniospectroradiometer (LSG-6000CCD)". LSG-6000CCD Goniospectroradiometer =LSG-6000 Goniophotometer System+LPCE-2 Integrating sphere Spectroradiometer System. Please click to download theLSG-6000CCD Brochure
• The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Portable CCD Spectroradiometer | CCD Detector and spectrum range is 380~780nm. Test lux and all color parameters. The size is compact and applicated with 5inch big LCD Screen, with... | |
Surge Generator | According to IEC 61000-4-5, EN61000-4-5 and GB/T17626.5. Output voltage wave is 1.2/50us with max 6KV and current wave is 8/20us with max 3KA. The ... | |
Automatic Electrical Safety Tester | It is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. The testing parameters include: AC/DC Withsta... | |
High Precision Spectroradiometer Integrating Sphere System | LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED’s quality ... | |
Electrostatic Discharge Simulator | According to IEC61000-4-2, EN61000-4-2 and GB/T17626.2. Output voltage is 0~20KV. Contact and Air Discharges test mode. The big LCD screen can be t... |
Похожие товары
Цифровой мультиметр Fluke 15B+ 17B+ 18B+, тестер напряжения и частоты | Продавец: Шэньчжэнь Weike Repair Technology Co., Ltd. | Полупрозрачная/полностью прозрачная/молочно-белая/светло-желтая паяльная паста iFixes 10CC, не со... | |
HTT-02 Hot Tack Tester | Продавец: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | Продавец: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | Продавец: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... | |
TST-01 Tensile Tester | Продавец: Cell Instruments Co., Ltd | TST-01 tensile testers are suitable for conducting a variety of tests, including tensile strength... |