EMI Receiver System
Product Description
EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for theEMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meetsCISPR15:2018,CISPR16-1,GB17743, FCC,EN55015and EN55022.
System Configurations:
• EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN-A Artificial Network Power (16A with RS-232 communicate), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers and cables.
• EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN-A Artificial Network Power (5A), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers, Attenuator and cables.
• EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN-A Artificial Network Power (5A), 3pcs Isolation Transformers, Attenuator and cables.
Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:
•LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Sourcefor EUT
•LISUN SDR-2000B Magnetic Shielding Cabinetfor the EMI Receiver System
•LISUN VVLA-30M Three Loop Antennato test 9k-30MHz Radiation
•LISUN AB-CLP Absorbing Clampto test the Home Applications & motor tools
Specification:
• Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA)
• Frequency stability: 1×10^-6
• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz
• Test Tolerance: ±2 dB
• Measure and Detection method: PK, QP and AV
• Measure range from 20dBμV to 140dBμV
• Frequency scanning step length: 20Hz~2MHz
• Sweep bandwidth: 200Hz; 9kHz; 120kHz
• Connect PC via USB cable and software can run on Win7, Win8 and Win10, Win11
What is EMI receiver?
Electromagnetic Interference (EMI receiver) is electronic noise that interferes with cable signals and reduces signal integrity. EMI Receiver is usually generated by electromagnetic radiation sources such as motors and machines. EMI Receiver (Electromagnetic Interference) has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space.
How to test EMI Interference?
Electromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test.
What's the difference between EMI and EMS?
EMC (ElectroMagneticCompatibility) literally translates to "electromagnetic compatibility". EMI (ElectromagneticInterference) "Electromagnetic Interference" can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (ElectroMagneticSusceptibility) literally translates to "electromagnetic sensitivity", which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy.
Noted: According to latestCISPR15:2018standard, you need to use CDNE-M316 (Coupling/Decoupling Network for Emission) to instead the CDN. The CDNE-M316 worked with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M-300mHz
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Portable CCD LED Colorimeter Spectroradiometer | The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters: LISUN Model Functio... | |
| High Precision Rotation Luminaire Goniospectroradiometer | LSG-1890BCCD/LSG-1800ACCD goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measur... | |
| High Precision Rotation Luminaire Goniophotometer | What is goniophotometer definition? LSG-1890B/LSG-1800Agoniophotometeris automatic goniophotometric instrument for luminous intensity distribution... | |
| LED Power Driver Tester | Product Description LS2090 LED Power Driver Test Instrument is the comprehensive test instrument for LED driver power which is according toGB/... | |
| EMI Receiver System | Product Description EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9K... |
Похожие товары
| Air Permeability Tester STD- F8 | Продавец: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | Продавец: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | Продавец: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | Продавец: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | Продавец: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |