EMI Receiver System
Product Description
EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for theEMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meetsCISPR15:2018,CISPR16-1,GB17743, FCC,EN55015and EN55022.
System Configurations:
• EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN-A Artificial Network Power (16A with RS-232 communicate), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers and cables.
• EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN-A Artificial Network Power (5A), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers, Attenuator and cables.
• EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN-A Artificial Network Power (5A), 3pcs Isolation Transformers, Attenuator and cables.
Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:
•LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Sourcefor EUT
•LISUN SDR-2000B Magnetic Shielding Cabinetfor the EMI Receiver System
•LISUN VVLA-30M Three Loop Antennato test 9k-30MHz Radiation
•LISUN AB-CLP Absorbing Clampto test the Home Applications & motor tools
Specification:
• Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA)
• Frequency stability: 1×10^-6
• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz
• Test Tolerance: ±2 dB
• Measure and Detection method: PK, QP and AV
• Measure range from 20dBμV to 140dBμV
• Frequency scanning step length: 20Hz~2MHz
• Sweep bandwidth: 200Hz; 9kHz; 120kHz
• Connect PC via USB cable and software can run on Win7, Win8 and Win10, Win11
What is EMI receiver?
Electromagnetic Interference (EMI receiver) is electronic noise that interferes with cable signals and reduces signal integrity. EMI Receiver is usually generated by electromagnetic radiation sources such as motors and machines. EMI Receiver (Electromagnetic Interference) has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space.
How to test EMI Interference?
Electromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test.
What's the difference between EMI and EMS?
EMC (ElectroMagneticCompatibility) literally translates to "electromagnetic compatibility". EMI (ElectromagneticInterference) "Electromagnetic Interference" can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (ElectroMagneticSusceptibility) literally translates to "electromagnetic sensitivity", which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy.
Noted: According to latestCISPR15:2018standard, you need to use CDNE-M316 (Coupling/Decoupling Network for Emission) to instead the CDN. The CDNE-M316 worked with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M-300mHz
在线联系供应商
Other supplier products
LED Power Driver Tester | Product Description LS2090 LED Power Driver Test Instrument is the comprehensive test instrument for LED driver power which is according toGB/... | |
LM-79 Moving Detector Type C Goniophotometer | LSG-6000 Moving DetectorGoniophotometer(Mirror Type C) was manufactured by LISUN completely meetsLM-79-19,IES LM-80-08,COMMISSION DELEGATED REGULAT... | |
Lamp Start, Run-up time and Flicker Test | Product Description LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric pr... | |
Electrostatic Discharge Simulator | Product Description ESD simulator guns(Electrostatic Discharge Generator/Electrostatic Gun/ESD Guns) is in full compliance withIEC 61000-4-2,E... | |
High Precision Spectroradiometer Integrating Sphere System | Basic Info. Model NO. LPCE-2 After-sales Service Perfect Warranty 24months Trademark LISUN Origin China ... |
Same products
MECHANIC MEC 4K 2K 高清电子目镜相机,适用于立体显微镜 | 卖方: 深圳市维客修科技有限公司 | 描述 美卡尼克MEC 2K/2K PRO/4K高清电子目镜摄像机,可以将双目立体显微镜改装成三目显微镜。采用SONY 1/2.3"进口CMOS传感器,采用优质CMOS传感器,硬... | |
Fluke 15B+ 17B+ 18B+ 数字万用表电压频率测试仪 | 卖方: 深圳市维客修科技有限公司 | iFixes 10CC半透明/全透明/乳白色/浅无铅助焊膏适用于手机主板CPU BGA维修。iFixes助焊剂注射器注射焊膏焊接膏手机整理焊接耗材系列,适用于电路板纳米芯片,手机PCB, SMT... | |
HTT-02 Hot Tack Tester | 卖方: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | 卖方: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | 卖方: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... |