Femoral Stem Neck Prostheses Fatigue Testing Machine

Standard

YY/T 0809.6 (China): Specifies neck fatigue testing for femoral stems in partial/total hip arthroplasty.

ISO 7206-6 (International): Defines protocols for evaluating the fatigue strength of femoral head-neck junctions.

ASTM F2023: Additional compliance for dynamic loading of ceramic femoral heads.

Adaptive Protocols: Customizable for emerging standards in biomaterial fatigue testing.

Product Advantages

Electromagnetic Precision: M-Series actuator delivers ±0.1% force accuracy with sub-micron displacement control.

10 Million Cycle Endurance: Proven capability to complete ISO 7206-6’s 10⁷-cycle fatigue test without drift.

R=0.1 Load Control: Advanced servo-hydraulic system maintains specified stress ratios throughout testing.

Real-Time Failure Detection: AI-driven algorithm identifies crack initiation at sub-millisecond intervals.

Ergonomic Workflow: 15.6” touchscreen with multilingual interface (English/Chinese/German) and pre-loaded SOPs.

Modular Test Chambers: Quick-swap environmental pods for simulated physiological testing (-20°C to +50°C).

Product Features

Electromagnetic Actuator: 5.340 N peak force capacity with 0.001 N resolution.

Dual-Axis Loading: Simultaneous axial/torsional loading (50 Nm max torque).

Dynamic Load Control: 1–30 Hz frequency range with programmable waveforms (sine, square, random).

Thermal Chamber Integration: ±0.5°C temperature stability for accelerated aging studies.

High-Speed Imaging Ready: Syncs with external cameras for full-field strain mapping (optional upgrade).

Safety First: Emergency stop, overload clutches, and laser-based specimen breakage detection.

Technical Parameters

ParameterSpecification
Max. Dynamic Force ±5.340 N (11.940 N peak optional)
Frequency Range 1–30 Hz (0.1 Hz increments)
Load Ratio (R) 0.1–10 (adjustable)
Axial Displacement ±10 mm (0.1 μm resolution)
Torque Capacity ±50 Nm (0.01 Nm resolution)
Temperature Range -20°C to +50°C (environmental chamber)
Data Sampling Rate 50 kHz (synchronized across 12 channels)
Power Requirements 220V/110V ±10%, 50/60Hz, 1.500W
Dimensions (W×D×H) 1.200 × 800 × 1.900 mm
Weight 550 kg (including thermal chamber)
Noise Level <70 dB (A-weighted)

Accessories

Femoral Neck Test Fixture Kit:

Self-centering collet system (12/14 mm taper compatibility)

Laser-aligned loading anvils with wear-resistant coating

Thermal Environmental Chamber:

15L capacity with rapid cooling/heating (10°C/min)

Corrosion-resistant 316L stainless steel interior

TestMaster Elite Software:

Automated fatigue life prediction (S-N/ε-N curve generation)

21 CFR Part 11-compliant audit trail with blockchain timestamping

Remote monitoring via iOS/Android app

Operator Kit:

Calibrated torque wrench set (0.5–25 Nm)

Specimen alignment gauges (ISO 7206-6 compliant)

Calibration Bundle:

NIST-traceable force calibration weights

Temperature verification probe

Safety Kit:

Laser safety curtains

Acoustic enclosure for noise reduction


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Foam Repeated Compression Tester
Foam Repeated Compression Tester Foam repeated compression testing machine will accurately measure the thickness of the test piece, placed in the compression plate of the testing m...
Intramedullary Nails/Bone Screw Static Torque Testing Machine
Intramedullary Nails/Bone Screw Static Torque Testing Machine Standard YY/T 0591-2011: Chinese standard specifying torsion testing methods for intramedullary nails, including torque application, angular displ...
Femoral Stem Neck Prostheses Fatigue Tester
Femoral Stem Neck Prostheses Fatigue Tester Standard YY/T 0809.6 (China): Specifies neck fatigue testing for femoral stems in partial/total hip arthroplasty. ISO 7206-6 (International): Def...
 Full Face Helmet Flame Resistance Tester
Full Face Helmet Flame Resistance Tester Full Face Helmet Flame Resistance TesterMedical mask fire test machine is to determine the fire resistance performance of medical face masks and fu...
Cleanliness Analysis System
Cleanliness Analysis System Production: The cleanliness analysis system fully complies with the requirements of standards such as VDA19.1 - 2015. ISO16232. ISO4406. ISO4407. ...
Все товары поставщика

Похожие товары

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 Продавец: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer Продавец: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester Продавец: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool Продавец: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester Продавец: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...