Countstar® Rigel S5 Advanced Image Cytometer

  • PBMC andPrimary Cell Counting
  • Cell Apoptosis
  • Cell Cycle
  • Surface Marker Analysis
  • GFP Transfection Efficiency
  • FCS Express Software

Product Overview
TheCountstarRigel S5 system increases the PE channel on the basis of Rigel S3, and can carry out multi-color fluorescence experiments in addition to rapid cell viability and concentration measurement, including cell apoptosis (Annexin V/PI/DAPI), cell transfection (GFP/YFP/RFP), CD marker experiment (DAPI/FITC/PE), and cell killing (Hoechst T33342/Calcein-AM/PI) and so on.

Excitation light: 375nm, 480nm, 525nm
Emission filter:460nm, 535nm, 580nm, 600LP


Key Benefits

All in one design- Integrated Computer/Touch scree
Automatic Detection 5 Samples in one single test sequence.
User Friendly Cell Analysis Protocols
Unrivaled "Fixed focus" patent, no manual focusing.
High Stability and Actuary
Powerful and user-friendly Data Management
GMP and 21 CFR part 11 ready
FCS Express Software

Product feature
SmartThe BioApps of the Countstar Rigel S3 System simplify routine cell lab tasks while providing high quality scientific data.
Countstar S3 comes with three BioApps to simplify and automate the routine cell count, viability and cytotoxicity tasks.

AO/PI Viability Protocol: Run two fluorescence color assays in disposable consumable to determine the percentages of live, dead cells and concentration in the presents of debris and unwanted nonnucleated cell types including red blood cells.
Affinity of Antibody: This assay run as Green color assays in FITC binding antibody to determine the affinity of the biosimilar drug.
Surface Marker Assay: Quantify specific cell populations based on surface marker expression (CD45+ CD4+, CD8 + MSC, CD56+ NK cells, etc.)
Cell Cycle: Propidium iodide (PI) is a nuclear staining dye that is frequently applied in measuring cell cycle. The protocol determining cellular DNA content in cell cycle analysis
Cell Apoptosis: Cell Apoptosis assay is a type used for determining the apoptosis percentage of cells by Annexin V-FITC/7-ADD staining method.
GFP transfection: The green fluorescent protein (GFP) exhibits bright green fluorescence when exposed to light in the blue to ultraviolet range. This protocol can analyze counting and percentage of GFP.
Celling Killing: Run three fluorescence color assays in disposable consumable to determine the CAR T/NK-Mediated Cytotoxicity using Tracer and Viability Dyes
Trypan blue Protocols: Obtain cell count, viability and concentration estimations based on trypan blue staining using a disposable consumable.

Three step process

The Countstar S3 System is designed to take you from sample to result in one go, simplifying your work and allowing for increased productivity and efficiency.


Reproducible and Accurate

Countstar S3 system can automatic detect 5 samples at one time, it will be more efficiency and affordable, with integrated patent “fixed focus”, the results would be more stable and reliable.


Touch Screen with Flexible Experiment Assay Management System

“App-like" interface. Allow to add multiple Experiment Assays for different operators


FCS Express Software

The optional De NovoTM FCS Express software makes graphs touchable and customizable fluorescence channel boost your experiment reach. Countstar Rigel S5 together with FCS Express is able to analyze for the cell apoptosis, cell cycle, transfection, affinity of antibody, CD marker and etc.


GMP ready

The Countstar S5 system is designed to meet the modern pharmaceutical requirements. The software complies with 21 CFR part 11. Key features include control of user access and data export, and secure audit trail. At the same time, we also supply IQ/OQ service and PQ support to help customer build a reliable system.
Specifications
Technical Specifications
Model: Countstar Rigel S5
Diameter range: 3μm ~ 180μm
Concentration range: 1×104 ~ 3×107/mL
Objective magnification: 5x
Imaging element: 1.4 megapixel ,CCD camera
Excitation Light 375nm, 480nm, 525nm
Emission Filter 460nm, 535nm, 580nm, 600LP
USB 1×USB 3.0 1×USB 2.0
Storage: 500GB
Power supply: 110–230 V/AC, 50/60Hz
Screen: 10.4 inch touchscreen
Weight: 13kg (28lb)
Size (W X D X H): Machine: 254×303×453mm Package size: 430×370×610mm
Operating temperature: 10℃ ~ 40℃
Working humidity: 20% ~ 80%
Applications
Dual-Fluorescence Viability
Acridine orange (AO) and Propidium iodide (PI) are nuclear nucleic acid binding dyes. The analysis excludes cell fragments, debris and artifacts particles as well as undersized events such as platelets, giving a highly accurate result. In conclusion, theCountstarsystem can be used for every step of the cell manufacturing process.

T/NK cell mediated cytotoxicity

By labeling the target tumor cells with CFSE ortransfectwith GFP. Hoechst 33342 is used for stain all cells (both T cells and tumor cells), alternatively, target tumor cells can be stained with CFSE, PI is used forstainthe dead cells (both T cells and tumor cells). This staining strategy allows for the discriminate of different cells.


Cell Apoptosis

The different phases of apoptosis are segmented into an early, middle and late stage. Specified indicators can document the single stages of apoptosis. The Countstar® Rigel S5 offers a visualized image-based solution and analyzes all of these steps with pre-loaded protocols in depth.

Cell Cycle
CountstarRigel S5 enables users to get the result of a cell cycle quickly and accurately.CounstarRigel S5 can analyzeproportionof cell indifferentphase of the cell cycle.

Surface Maker Analysis
A lymphocyte subsets analysis is a typical experiment performed incell relatedresearch fields and various diseases diagnosis. Countstar® Rigel S5 offers a faster and easier way to make immune cell typing more efficient. With visible cell images and powerful data analysis

Affinity of antibody
Detect affinity of antibody in cell level is an important indicator of monoclonal antibody detection using immunofluorescence method.TheCountstar® Rigel S5 offers a rapid, direct and reliable evaluating method for the affinity of antibody detection in antibody drug screening

GFP Transfection Efficiency
In cell and molecular biology, the GFP gene is frequently used as a reporter of expression. Currently, scientists are commonly using the fluorescent microscopes or flow cytometers to analyze the transfection efficiency of mammalian cells. ButFlow cytometryrequires a high-qualified and experienced operator. WhileCountstarRigel S5 enables users to get the result of a transfection efficiency assay quickly and accurately.



Отправить запрос, связаться с поставщиком

Кому: ALIT Life Science Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Countstar® BioMed Professional Immune Cell Counter
Countstar® BioMed Professional Immune Cell Counter 1. Trypan blue Cell Counting2.Immune Cell Counter3. Cell Diameter Analysis4. Cultivation time chart (CTC) Product OverviewIn order to meet the...
Countstar® BioFerm Automated Yeast Cell Counter
Countstar® BioFerm Automated Yeast Cell Counter Yeast Cell CountPitching YeastBrewing YeastProduct OverviewThe Countstar® BioFerm Automatic Yeast Counter combines traditional Melanie or Methy...
Countstar® BioTech Automated Cell Counter
Countstar® BioTech Automated Cell Counter Accurate cell analysis for: Trypan blue Cell Counting Aggregated Cell Analysis Cell Diameter Analysis Cultivation time chart (CTC) Produ...
Countstar BioFerm
Countstar BioFerm Automated Yeast Cell Counter Yeast Cell Counting Pitching Yeast Brewing Yeast Product Overview The Countstar® BioFerm Automatic Yeast Counter ...
Countstar® Rigel S2 Fluorescence Cell Analyzer
Countstar® Rigel S2 Fluorescence Cell Analyzer Precise cell analysis for: PBMCs, whole blood, Car-T Stem Cell Analysis Splenocytes Monocytes And Other Primary Cells Product Ove...
Все товары поставщика

Похожие товары

Digital Construction
Digital Construction Продавец: FJ Dynamics Co., Ltd. We don’t do construction, but we are transforming construction. FJD machine control system ...
FJD WiFi Camera for Autosteering Kit
FJD WiFi Camera for Autosteering Kit Продавец: FJ Dynamics Co., Ltd. $299.00 Tax excluded. Taxes and Shipping calculated at checkout Quantity: 1 Compatible wi...
Nitinol Tube
Nitinol Tube Продавец: Baoji City Changsheng Titanium Co.,Ltd Nickel titanium alloy is a type of shape memory alloy, which is a special alloy that can automati...
Molybdenum Sheet & Molybdenum Foil
Molybdenum Sheet & Molybdenum Foil Продавец: Baoji City Changsheng Titanium Co.,Ltd In refractory metals, molybdenum sheet has good thermal conductivity, electrical conductivity and...
Extension Sets
Extension Sets Продавец: Shanghai Kohope Medical Devices Co., Ltd. Now, we provide various types of extension sets, including iv extension set with injection port, ...