Nozzle flowmeter
Nozzle flowmeter
Product name:nozzle flowmeter
Product code:152659-821
Update time:2015.08.25
Views:1277
Processing custom origin:in kaifeng
Type:type SKLGB series
Type:nozzle throttling device
Measuring range:1932 nozzle: 50 ~ 500; The length to diameter nozzle: 50-630
Nominal size:DN50-DN1000
The accuracy of measurement:1-2.5
Nominal pressure:10 or less (Mpa)
Scope of application:gas and liquid
throttling device, also known as differential pressure flowmeter, Orifice flowmeter contains (integrated orifice flow meter, standard orifice, annular orifice flow meter, integrated annular orifice flow meter)
Nozzle flow meter (integrated nozzle flow meter)can be divided according to function name gas flow meter, flue gas meter, steam flow meter, gas flow meter, compressed air flow meter, liquid flow meter.
Throttling coffret - nozzle flowmeter has many advantages, but generally feel pressure pipeline installation on site work is large, also easy to leak, congestion and other issues. Differential pressure transducer made by leaps and bounds in recent years of development, not only the small size, and stable performance, easy to adjust, in use process basically don't need to adjust the zero point. These advantages contribute to a body orifice flowmeter (including orifice plate, the annular orifice, nozzle, etc.) in the development and application. Nozzle flow meter is to measure flow differential pressure generator, cooperate with all sorts of differential pressure gauge or differential pressure transmitter to measure all kinds of fluid flow in pipes. Standard nozzle throttling device with differential pressure transmitter, can measure the rate of flow of liquid, steam, gas, nozzle flowmeterhas a long history background, all kinds of test data is complete. Simple structure, no moving parts, stable and reliable long-term use, rich experience in design and manufacture and application. Doesn't need a high degree of standardization, solid flow calibration. Standard orifice has reliable experimental data and improve the international and national standards. In foreign countries and has its inherent in the huge domestic market, users are familiar with, data; Follow the international standard calculation and processing, use agile and convenient; According to relevant data of estimate of flow meter between 60% and 70% of the total consumption. It is widely used in petroleum, chemical, metallurgical, power, light industry and other departments.
Features:
Nozzle flowmeter smaller pressure loss;
To save energy;
More strong and durable;
Suitable for high temperature and high pressure fluid;
Widely used in electric power, chemical and other industries of steam flow measurement;
Nozzle flowmeter include standard nozzle (ISA1932 nozzle) and two long neck nozzle. The design and manufacture are in accordance with international standard ISO5167 or the provisions of the national standard GB/T2624.
Standard nozzle plane perpendicular to the axis of the entrance by part A, circular arc form surface contraction section B and C of entrance, the edge of cylindrical throat E and to prevent damage to the protective tank F, pressure from its ways upstream pressure mouth Angle of using access, downstream take pressure can be set up by the pressure of Angle joint, also can be set up in the far downstream.
The total length of the nozzle
When 0.30 beta 2/3 or less or less, the nozzle length = 0.6041 d
When two-thirds beta 0.80 or less or less, the nozzle length = {0.4041 + (0.75 / beta 0.25 beta 2-0.5225) 0.5} d
SKLGB type series nozzle flowmeter throttle device upstream face by perpendicular to the axis plane and profile for the two arcs of a circular, cylindrical throat and groove for the identified contraction of the nozzle. SKLGB type series nozzle flowmeter throttle device way of selecting pressure Angle only pressure a pick up.
Length to diameter nozzle upstream face by perpendicular to the axis plane and profile for the quarter ellipse contraction, cylindrical throat and possible grooves or Angle of the nozzle. Length to diameter of nozzle take pressure way - D / 2 D only take one pressure.
The main technical parameters:
Nominal diameter (mm) : (- DN1000
Nominal pressure (MPa) : 10 or less
Ambient temperature: - 20 ℃ to 55 ℃
Fluid temperature: - 20 ℃ to + 300 ℃ :
Function coffret: according to user's request matching related instrument, to realize signal remote transmission (can have fieldbus function), or bring about intelligent compensation, according to flow to mass flow, standard volume flow, etc.
Applicable medium: especially suitable for high temperature and high pressure steam and water, can also be used for all kinds of gas, liquid;
Nominal diameter: (- 500 - mm (DN > 500 can also design and production);
Job stress: ≦ 42 mpa working temperature: - 50 ℃ to 650 ℃;
Take method of pressure: Angle joint (single loop room, flange ring room directly or drilling) take pressure;
Way: the nozzle flange (direct drilling and pressing pieces), fastener holding room, fasteners, clamping flange, ring type clamping piece (pressure) and welding;
Execution standard: IS05167; GB/T2624 accuracy: conform to the standard: + / - 1.0%;
Material: flange or clamping piece: optional according to the medium temperature of carbon steel, alloy steel, stainless steel, etc
Spray nozzle: stainless steel 304, 316;
Length to diameter nozzle:
Applicable medium: especially suitable for high temperature and high pressure steam and water, can also be used for all kinds of gas, liquid;
Nominal diameter: (- 630 - mm;
Job stress: ≦ 42 mpa working temperature: - 50 ℃ to 650 ℃;
Take pressure method: the span (D - D / 2) apply pressure;
Nozzle installation: installed with upstream or downstream and welding section again according to the span (D - D / 2) set to take pressure hole;
Execution standard: IS05167; GB/T2624;
Accuracy: conform to the standard: + / - 2.0%;
Material: upstream or downstream section according to the medium temperature optional carbon steel, alloy steel, stainless steel, etc
Spray nozzle: stainless steel 304. 316;
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Nozzle flowmeter | Nozzle flowmeter Product name:nozzle flowmeter Product code:152659-821 Update time:2015.08.25 Views:1277 Processing custom origin:in kaifeng ... | |
| Top mounted magnetic float liquidometer | Top mounted magnetic float liquidometer Product name:high temperature and high pressure type magnetic flap level gauge Product code:15644-178 Up... | |
| Ring chamber orifice meter | Ring chamber orifice meter Product name:Ring chamber orifice meter Product code:151116-813 Update time:2015.08.25 Views:860 Processing custom ... | |
| impeller type flowmeter | Turbine flowmeter compressed air flowmeter gas flowmeter Product name:turbine flowmeter Product code:164912-752 Update time:2015.08.25 Views:... | |
| nozzle flowmeter manufacturer | Nozzle flowmeter nozzle flowmeter manufacturer Product name:nozzle flowmeter Product code:152659-821 Update time:2015.08.25 Views:1277 Proces... |
Похожие товары
| HYJL-12 High Voltage Metering Cabinet (box) | Продавец: Hebei Tongdian Electric Equipment Technology Co., LTD | HYJL-12 High Voltage Metering Cabinet (box) HYJL-12 high voltage metering cabinet(box) (hereinaf... | |
| PH-A6 Водонепроницаемый перьевой высокоточный измеритель pH / температуры | Продавец: Келийлонг Электронные Акционерные Компании | PH-A6 Водонепроницаемый перьевой высокоточный измеритель pH / температуры 36 лет углублённой раб... | |
| PH-A6 Водонепроницаемый перьевой высокоточный измеритель pH / температуры | Продавец: Келийлонг Электронные Акционерные Компании | PH-A6 Водонепроницаемый перьевой высокоточный измеритель pH / температуры 36 лет углублённой раб... | |
| PH-9082 Водонепроницаемый перьевой высокоточный измеритель pH / температуры | Продавец: Келийлонг Электронные Акционерные Компании | PH-9082 Водонепроницаемый перьевой высокоточный измеритель pH / температуры Целевое позициониров... | |
| Battery Powder Compaction Density Evaluation System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Measurement of tapped de... |















