Safety Helmet Roll-off Testing Equipment
Purpose
Apply an initial load of a certain force to the rear of the helmet. Then, let a weight specified by the standard fall from a certain height so that the impact force is also applied to the helmet. In this way, the wearing stability performance of the helmet can be evaluated.
Test standard:
IS 4151 , ECE R22.05
Mass of initial load: 3 kg ± 0.1 kg
Mass of falling weight: 10 kg ± 0.01 kg
Lowering height: 0.5 meters ± 0.01 meters
Measuring method: manual
Electricity: 220V 50HZ
Test theory: vertical descent
Test steps:
1. previously to the ambient temperature and sanitary conditions for the conditions of the helmet, should be placed on the appropriate head shape and fixed in the appropriate head.
2. In the median vertical plane of the helmet, a device that guides and releases the fall with a total mass of 3 kg ± 0.1 kg is attached to the rear of the shell.
3. 10 kg ± 0.01 kg of falling mass is released and lowered from a height of 0.5 m ± 0.01 m. The guiding device should ensure that the impact velocity is not less than 95% of the theoretical velocity.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Carpet Pilling Formation Tester | Instrument Description This instrument is used to simulate the pilling and fuzzing phenomena that occur during the normal use of carpets. The inst... | |
| Fabric Washing Shrinkage Test Machine | Standards: AATCC 88B, AATCC 88C, AATCC 124. AATCC 130. AATCC 135. AATCC 142. AATCC 143. AATCC 150. AATCC 159. AATCC 172. AATCC 179. AATCC 188 A... | |
| Hydrostatic head Tester | Introduction The hydrostatic head tester is designed to test the pressure that the material does not come into contact with the exuded water dropl... | |
| Limiting Oxygen Index Chamber | Product details The Limiting Oxygen Index (LOI) fire test is perhaps the most economical and precise quality control test for combustible material... | |
| Battery impact tester | The test sample cell is placed on a flat surface with a 15.8±0.2mm(5/8 in) diameter rod placed in a cross position over the center of the ... |
Похожие товары
| FH-77 Dissolved hydrogen meter | Продавец: Коллирон электроникс лимитед | Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy... | |
| Xenon Arc Weather Ometer | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... | |
| Plastic Smoke Density Tester F313 | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ... |