Adiabatic Accelerated Calorimeter
Product Description
Adiabatic Accelerated Calorimeter determines the thermal behavior of samples under adiabatic conditions by keeping the temperature of the environment and the reaction system equal, obtains the thermodynamic and kinetic data of the chemical reaction process in adiabatic state, and deduces the key indexes for evaluating the thermal safety of the chemicals or the chemical reaction such as TD24. TMRad, SADT, etc., so as to determine the safety conditions for the processing, storage and transportation of the chemicals accordingly. It is widely used in the research and development and optimization of chemical processes in the fields of fine chemicals, petrochemicals, agricultural fertilizers, polymers and plastics, energy-containing materials, etc.; the effective assessment of thermal hazards in the process of storage and transportation of chemicals; and the scientific research on the thermodynamics of chemical reactions. It is mainly used for chemical process research and development, process optimization and scale-up, chemical thermal hazard assessment, investigation and analysis of combustion and explosion accidents, and thermodynamic research in the fields of fine chemicals, pharmaceuticals, energy-containing materials, organic chemistry, polymers and plastics, and so on.
Standards
T/CIS 17007-2023
JJF 1059.1-2012
JJF 1001-2011
Product Features
1. Supports Heating - Waiting - Scanning (HWS) mode, constant - temperature mode, isochronous scanning mode, etc. 2. Equipped with professional data - analysis software, enabling automatic calculation of parameters such as exothermic onset temperature, adiabatic temperature rise, activation energy, and pre - exponential factor. 3. The software integrates the safety risk assessment methods and standards for reactions in the *Guidelines for Safety Risk Assessment of Fine Chemical Reactions* issued by the former State Administration of Work Safety, enabling one - stop assessment of the hazard level of reaction processes. 4. Key components are from well - known international brands, ensuring the long - term and stable operation of the instrument. 5. After the experiment, an inert gas can be introduced to rapidly cool down the furnace body. 6. Features an experimental status indication function, as well as overpressure and over - temperature alarm functions. 7. The furnace cover has an automatic lifting function, ensuring safety and facilitating operation. 8. With professional industrial design, it is simple and elegant, has a user - friendly human - machine interaction, and is easy to learn, understand, and operate. 9. The data - analysis software incorporates the differential conversion - rate thermodynamics calculation method, which has significant advantages in the calculation of the thermal decomposition kinetics of mixed materials and the prediction of thermal hazards.
Technical parameters
|
Operating Environment |
(5~40)℃, <85%RH |
|
Temperature Control Range |
Room temperature~500℃ |
|
Temperature Detection Threshold |
(0.005~0.02)℃/min |
|
Temperature Tracking Rate |
(0.005~40)℃/min |
|
Temperature Display Resolution |
0.001℃ |
|
Pressure Range |
Maximum withstand pressure 20MPa |
|
Pressure Resolution |
1kPa |
|
Sample Cell Specifications |
8mL |
|
Sample Cell Material |
Stainless steel, titanium, Hastelloy (optional) |
|
Phi Value |
≤1.35 |
|
Interfaces |
USB or RJ45 |
|
Power Supply |
AC220V/50Hz |
|
Power |
≤3000W |
|
Dimensions |
620mm*470mm *670mm |
|
Weight |
Approx. 78kg |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| NFPA 701-1 Flammability Tester | Introduction This tester mainly based on NFPA 701 R & D and the United States NFPA 701 that provides fabric and film flame propagation test me... | |
| Safety shoe impact testing machine | According to the criteria Bs-953.1870 EN-344. ANSI-Z41 CSA-Z195 ISO K88782 EN ISO 20344. ANSI-Z41 BS EN-344 CSA-ZI95 LD50-1994 AS/NZS 22... | |
| Oxidizing liquid time pressure tester | Product Description: Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria 11.6.1 Test 1(c)(i): Time... | |
| Liquid Sustained Combustion Test device | Product Introduction This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 32.5.2 Test L... | |
| Femoral Condyles Components Fatigue Performance Tester | Standard ASTM WK51649: Specifies fatigue testing protocols for metallic femoral components in total knee arthroplasty, including F-N curve generat... |
Похожие товары
| Custom Stainless Components for OEM Applications | Продавец: Yongjia County Yaokang Technology Co., Ltd. | Our stainless steel float balls are designed for float valves, water tanks, and industrial liquid... | |
| FH-77 Dissolved hydrogen meter | Продавец: Коллирон электроникс лимитед | Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy... | |
| Xenon Arc Weather Ometer | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... |