Negative Pressure Blood Tube Capacity Tester

The main uses, compliance standards, and technical parameters of the Vacuum Blood Collection Tube Aspiration Volume Tester are as follows:

Compliance Standards:

The design and manufacture of the Vacuum Blood Collection Tube Aspiration Volume Tester must comply with relevant medical industry standards, such as YY 0314 - 2021Disposable Human Venous Blood Sampling Containers. This standard clearly specifies key indicators, including the error range of the aspiration volume of blood collection tubes, container leakage tests, and container strength tests, to ensure the usability and safety of blood collection tubes. The tester must strictly adhere to these standards during the design and manufacturing process to ensure the accuracy and reliability of test results.

Main Uses:

The Vacuum Blood Collection Tube Aspiration Volume Tester is mainly used to detect the aspiration volume of disposable human venous blood sampling containers, especially to check whether they meet the standard requirements in different altitude areas. The tester precisely measures the aspiration volume of blood collection tubes by simulating different altitude or air pressure conditions, thereby evaluating the performance of blood collection tubes in various environments. This is crucial for ensuring the accuracy and reliability of blood collection tubes in actual use, and helps maintain the quality of blood samples and the accuracy of diagnostic results.

Technical Parameters:

Vacuum Degree:The test range is usually 0 - - 90kPa to meet the testing requirements of different altitude areas.

Vacuum Degree Accuracy:Generally 0.5 - level to ensure measurement precision.

Vacuum Degree Maintenance Performance: It has automatic air - supplement and constant - pressure maintenance functions to ensure the stability of the vacuum degree during the testing process.

Operation Control Mode:It adopts fully automatic control and touch - screen operation, simplifying the testing process and improving testing efficiency.

Air Source Pressure Requirement:Usually 0.7 - 0.9MPa (the air source should be provided by the user) to ensure the normal operation of the tester.

Air Source Generator: Imported components (such as SMC generators from Japan) are used, with a stability of ±0.1kPa, improving the accuracy of testing.

Power Supply: It supports multiple power supply specifications such as AC 220V 50Hz/120V 60Hz to adapt to different regional power environments.

External Dimensions: The main unit size is usually 300mm(L)×385mm(W)×150mm(H) (the specific size may vary depending on the model), making it convenient to place and operate.

Weight:The net weight of the main unit is approximately 7kg (the actual weight may vary depending on the configuration), facilitating portability and movement.

Language: It supports Chinese/English (standard configuration), and other interfaces such as Russian and Traditional Chinese can be customized to meet the needs of different users.


Отправить запрос, связаться с поставщиком

Кому: Qinsun Instruments Co., LTD
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Gas Hazardous Characteristics Tester
Gas Hazardous Characteristics Tester Product Introduction This tester is used to test the flammable concentration range of gases in air. It is suitable for the vast majority of pure f...
Anti-glare Panel Falling Weight Tester
Anti-glare Panel Falling Weight Tester Scope of application: The anti-glare board impact testing machine is designed and produced for each testing unit to measure the impact resistance ...
Surgical Needle Penetration Force Tester
Surgical Needle Penetration Force Tester The Sharpness and Strength Tester for Suture Needles is a device specifically designed to detect the sharpness and strength of medical suture needl...
Protective Clothing Synthetic Blood Penetration Tester
Protective Clothing Synthetic Blood Penetration Tester Standard GB 19082-2003《Medical disposable protective clothing technology requires synthetic blood penetration test method》; ASTM F1670 / F1670M -...
Rupture strength tester
Rupture strength tester Standard IEC 61730-2: Photovoltaic (PV) Module Safety Qualification – Requirements for Testing UL 61730: Safety Standard for Photovoltaic M...
Все товары поставщика

Похожие товары

FH-77 Dissolved hydrogen meter
FH-77 Dissolved hydrogen meter Продавец: Коллирон электроникс лимитед Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy...
Xenon Arc Weather Ometer
Xenon Arc Weather Ometer Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ...
Xenotest | Light Fastness Tester Si220 (SunTest)
Xenotest | Light Fastness Tester Si220 (SunTest) Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ...
Ozone Aging Chamber
Ozone Aging Chamber Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum...
Plastic Smoke Density Tester F313
Plastic Smoke Density Tester F313 Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ...