150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Fire Resistant Instrumentation Control Cables

Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Unarmoured Instrumentation & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Lay-up: Pairs, triples, quads.Individual Screen: Aluminium/polyester tape + drain wire tinned copper.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 8×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightConstruction
No. of cores×Cross section(mm²)Nominal Insulation Thickness
mmNominal Sheath Thickness
mmMinimum Overall Diameter
mmMaximum Overall Diameter
mmApprox. Weight
kg/kmMultipair1×2×0.750.81.08.19.8973×2×0.750.81.214.016.02277×2×0.750.81.419.021.144912×2×0.750.81.623.826.474020×2×0.750.81.930.433.5118327×2×0.750.82.034.637.9155537×2×0.750.82.240.544.318461×2×10.81.08.510.31083×2×10.81.315.017.02647×2×10.81.420.022.552212×2×10.81.725.428.086520×2×10.81.932.135.3137727×2×10.82.136.840.2181437×2×10.82.343.047.02432Multitriple1×3×0.750.81.08.19.81043×3×0.750.81.315.017.02697×3×0.750.81.520.823.352712×3×0.750.81.725.828.58801×3×10.81.18.710.51243×3×10.81.315.817.93107×3×10.81.522.024.562212×3×10.81.827.530.21032Multiquad1×4×0.750.81.19.110.91373×4×0.750.81.417.419.53667×4×0.750.81.623.526.17251×4×10.81.19.611.41483×4×10.81.418.420.64137×4×10.81.624.927.6843
Other supplier products
|
|
|
PE Insulated,Website:, LSZH Sheathed, Individual & Overall Screened, Armoured Instrumentation Cables (Multitriple)RE-2Y(St)HSWAH-TiMF 70°C / 300 VS... |
|
|
|
NTSCGERLWOEU 3.6/6kV Flexible Submersible Cable VDE 0250 Part 813ApplicationsThese cables are used for permanent operation inwater where the cable ... |
|
|
|
Fire Resistant RS485 Databus Cables Application:The cables are designed for RS485 data connections where continued functionality is required during... |
|
|
|
Type 441 (class 1) 3.3 to 22KV to AS/NZS 2802ApplicationsType 441 Class 1 series cable has lower insulation and sheath radials than Class 2 cables,... |
|
|
|
Fire Resistant RG11 A/U Coaxial Cables RG11 A/U FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation m... |
供应产品
Same products