H03V2V2-F/H03V2V2H2-F

VDE Standard Industrial Cables H03V2V2-F/H03V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, office for light service or light portable apparatuses. With tdeir special insulation and sheatd compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoided.Standard and ApprovalHD 21.12; HD 308 S2 DIN VDE 0281 part 1, part 12; DIN VDE 0293 part 308; DIN VDE 0295 CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), EN50265-2-1Cable Construction- Bare copper fine wire conductor- Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383- PVC core insulation T13 to VDE-0281 Part 1- Color coded to VDE-0293-308- PVC outer jacket TM3Technical Characteristics- Working voltage: 300/300 volts- Test voltage: 3000 volts- Flexing bending radius: 15 x Ø- Static bending radius: 4 x Ø- Flexing temperature: +5º C to +90º C- Static temperature: -40º C to +90º C- Short circuit temperature: +160º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETERMMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KMH03V2V2-F20(16/32)2 x 0.500.50.659.63820(16/32)3 x 0.500.50.65.414.44520(16/32)4 x 0.500.50.65.819.25518(24/32)2 x 0.750.50.65.514.44618(24/32)3 x 0.750.50.6621.65918(24/32)4 x 0.750.50.66.528.872H03V2V2H2-F20(16/32)2 x 0.500.50.63.2 x 5.29.73218(24/32)2 x 0.750.50.33.4 x 5.614.435
Other supplier products
|
|
|
RG58 Armoured Coaxial Cable NEK 606Applications :These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine ... |
|
|
|
XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Pair)RE-2X(St)H 90°C / 300VSTANDARDSBasic design to EN 502... |
|
|
|
Central Loose Tube Optical Fiber CablesApplicationThese optical fiber cables are designed to data transmission in ship and specially in cruise ship... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9773,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9838ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |