Drill Pipe Magnetic Flux Leakage Detector MFL-308

Specifications: diameter Φ73 / Φ89 mm, length 9.6m or so

Detection speed: 6-20 m / min

Acceptance criteria: American Petroleum Institute API testing standards

The main mfl pipeline inspectionmethod principle is that the workpiece is magnetized (close to saturation) to have a certain magnetic flux density to generate a leakage magnetic field at the discontinuity, and the magnetic field sensor sends the output signal to the operational amplifier.

Due to the magnetic saturation state, the workpiece has a relatively high magnetic field strength and magnetic field density, and the magnetic lines of force are not limited so that the surface of the workpiece has a large magnetic leakage, which is favorable for on-site detection.

The magnetic sensitive sensor scans along the surface of the magnetized ferromagnetic material, pick up the defect leakage magnetic field and forms a defect electrical signal to achieve the purpose of finding the defect position and parameters.

MFL magnetic flux leakage inspectiontechnology is widely used in the detection of metal materials and the evaluation of related products due to its fast detection speed, high reliability and low surface cleanliness. Different from magnetic particle detection and detection, the signal in magnetic flux leakage detection is not displayed by magnetic powder, and it has no pollution to the environment: due to various sensitive components (such as Hall element and coil method), the detection result is directly output by electric signal, which is easy to connect with computer to realize digital Processing, so the detection results can be stored and reproduced, facilitating the analysis of the detection signal and the trend analysis of the detection results.

Drill Pipe Magnetic Flux Leakage Detector MFL-308 Performance

Drill pipe inspection method

Drill pipe straight ahead, test assembly

fixed

Detection range

F60-F168drill pipe

transport system speed

6-20m/min;variable frequency range

Testing methods

Automatic charging, Automatic testing,

Automatic sorting

The sensitivity of hole detection

Accuracy of section area

measurement

2-4%

Position resolution accuracy

20mm

Non-detection zone

£100mm(drill pipe body)

False alarm rate

£0.5%

Remaining magnetism after

demagnetization

£10GS

The internal and external surface

coverage

100%

Equipment usage environment

Working temperature:40°-minus50°;

Working humidity:0-95%;

BKNis one of professional mfl suppliers. We provide Magnetic Flux Leakage Testing, eddy current testing and so on. Want to know more? Please contact us.


Send product request

To: Nanjing BKN Automation System Co.,LTD
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Bearing Ring Crack and Hardness Combination Flaw Detector TQJC-02
Bearing Ring Crack and Hardness Combination Flaw Detector TQJC-02 The technology of BKN originated from eddy current Laboratory of Institute of Materials, Nanjing University of Technology. At present, it is a lead...
GSET-551 Steel Wire Eddy Current Flaw Detector
GSET-551 Steel Wire Eddy Current Flaw Detector GSET-551 Steel Wire Eddy Current Flaw Detector GSET-551 Steel Wire Eddy Current Flaw Detector Brief Introduction Using the eddy current signa...
Drill Pipe Magnetic Flux Leakage Detector MFL-308
Drill Pipe Magnetic Flux Leakage Detector MFL-308 Specifications: diameter Φ73 / Φ89 mm, length 9.6m or so Detection speed: 6-20 m / min Acceptance criteria: American Petroleum Institute ...
Steel Bar Testing
Steel Bar Testing The steel bar is rolled by a rolling mill and produce both surface defects and internal defects during the rolling process. The internal defect is ...
LGET-553 Aluminum Tube Eddy Current Flaw Detector
LGET-553 Aluminum Tube Eddy Current Flaw Detector LGET-553 Aluminum Tube Eddy Current Flaw Detector Brief Introduction The aluminum tube is a type of non-ferrous metal which may have one or more...
All supplier products

Same products

Microcrystalline wax used for rubber plastic processing and modification
Microcrystalline wax used for rubber plastic processing and modification Seller: Syntop chemical Co.,Ltd. Microcrystalline wax has a wide range of industrial applications, primarily in the areas of rubbe...
Microcrystalline wax 80A used for lubrication and demolding
Microcrystalline wax 80A used for lubrication and demolding Seller: Syntop chemical Co.,Ltd. The core industrial applications of microcrystalline wax 80A are primarily focused on rubber prot...
Tyvek Flat Roll Pouch
Tyvek Flat Roll Pouch Seller: Hopeway AMD Tyvek Flat Roll Pouch is designed for professional sterilization packaging, offering clean handli...
Industrial Warehouse Ceiling Fans
Industrial Warehouse Ceiling Fans Seller: Hebei Windmax Power Technology Co., Ltd. Industrial Warehouse Ceiling Fans Industrial Warehouse Ceiling Fans for Warehouses, Logis...
HVLS Ceiling Fan for Railway Station
HVLS Ceiling Fan for Railway Station Seller: Hebei Windmax Power Technology Co., Ltd. HVLS Ceiling Fan for Railway Station for Railway Station All units are CE-certified, manufa...