ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM
ASPE Ultra series Automated Solid Phase System is an automated sample preparation system designed for analysis of organic substances in water samples, including drinking water, tap water, underground water, surface water as well as wastewater. RayKol ASPE Ultra automate liquid liquid extraction equipment can be used in the purification and enrichment of target compounds in water samples before analytical instrumentation, it automatically completes the steps of filtering, conditioning, loading, rinsing, drying, eluting and concentration, fully unattended extraction, avoiding exposure of hazardous chemicals to lab technicians, easy to build up a smart and safe laboratory environment.
ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTIONSYSTEM FEATURES
Fully automatically preprocess water samples before analytical instrumentation
Good parallelism and reproducibility by independent pump-valve system and stable flow rate control
Avoid environmental interferences by a light-proof hood and airtight cavity design
Higly compatible with various applications, disk and column automated solid phase extraction available
Real-time monitoring, easy to access anytime
ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM SPECIFICATIONS
Parameter |
Specification |
|
Product |
ASPE Ultra 06 |
ASPE Ultra 08 |
Extraction channel |
6 |
8 |
SPE disks |
25mm, 47mm |
25mm, 47mm |
SPE cartridges |
3mL, 6mL, 12mL |
3mL, 6mL, 12mL |
Solvent capacity |
7 |
7 |
SPE column drying |
Vacuum; |
Vacuum; |
nitrogen gas purge+vacuum |
nitrogen gas purge+vacuum |
|
Material contact with solvents |
Teflon, glass |
Teflon, glass |
Waste discharge channel |
3 |
3 |
(water sample waste; organic waste; organic waste contain fluorine) |
(water sample waste; organic waste; organic waste contain fluorine) |
|
Software interface |
Built-in screen control |
Built-in screen control |
Dimension |
66cm x 58cm x 76cm |
66cm x 58cm x 76cm |
Weight |
50kg |
50kg |
Power supply |
200 to 240V, 50/60Hz |
200 to 240V, 50/60Hz |
Power rate |
450W |
450W |
Storage temperature |
0 to 40°C |
0 to 40°C |
Storage humidity |
20 to 85% |
20 to 85% |
Operating temperature |
10 to 40°C |
10 to 40°C |
Operating humidity |
20 to 80% |
20 to 80% |
ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM APPLICATIONS
ASPE Ultra Automated Solid Phase Extraction System targets in trace organic compounds in all kinds of water, can be mainly applied in the fields and industries of:
✔ Disease control
✔ Environmental monitoring
✔ Municipal water
✔ Geology and mining
✔ Acadamic
✔ Hydrology
TYPES OF ANALYSIS USING ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM
Environmental sanitation - Standards for drinking water quality
Standard examination methods for drinking water
Environmental quality standard for atmosphere, water and soil - Ground water
Environmental quality standard for atmosphere, water and soil - Surface water
Standard of water quality examination methods for urban water supply
Urban water supply - Determination of stibium
Urban water supply - Determination of sodium, magnesium, calcium - Ion chromatography method
Urban water supply - Determination of organic phosphorous pesticides - GC method
Urban water supply - Determination of volatile organic compounds
We can offer kinds of total laboratory automation systemfor sale, if you have needs lab automationsystem, please contact us.
Send product request
Other supplier products
RAYCURE QUECHERS CERAMIC HOMOGENIZERS | RayCure QuEChERS Ceramic homogenizerscan effectively increase sample preparation efficiency by their excellent homogenizing and dispersing abilitie... | |
RAYCURE QUECHERS EXTRACTION KITS | RayCure QuEChERS Extraction kitsare used in the step of extraction with salts in QuEChERS workflow, to transfer target analytes into organic phase ... | |
AUTOMATED LAB EQUIPMENT | Automated laboratory equipmentis increasingly becoming in demand as laboratories require for higher throughput and automation. These lab automation... | |
RAYCURE QUECHERS CLEAN-UP KITS | RayCure QuEChERS Clean-up kits are used in the step of purification with salts in QuEChERS procedure, to separate target compounds from interferenc... | |
SPE CARTRIDGES | RayCure SPE series provides high-quality SPE cartridges for various types of solid phase extraction, including manifold, vacuum as well as automate... |
Same products
Original Yogurt Flavor Mixed with Fruit Honey to Enhance Flavor | Seller: 853039 | Definition & Composition1. Flavor characteristicsMain flavor: Crisp Lactic Acid, produced by ... | |
Cheese Flavor High Temperature Resistant Flavor Agent for Bread Puffed Food | Seller: 853039 | Definition & Composition1. Flavor compositionCore flavor substances: butyric acid, acetic aci... | |
High Quality Brown Sugar Flavor for Drink Baked Desserts | Seller: 853039 | Definition & Composition1. Core flavor compositionCaramelization aroma: Furans: caramelized, ... | |
Micronized wax for improving scratch of coatings | Seller: Syntop chemical Co.,Ltd. | Micronized waxes are used as internal and external lubricants to reduce friction between plastic ... | |
High Concentration Rock Sugar Flavor Pure Sweet Used for Tea Dessert and Coffee | Seller: 853039 | Definition & Composition1. Core flavor compositionPure sweet taste: almost 100% sucrose cryst... |