ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM

ASPE Ultra series Automated Solid Phase System is an automated sample preparation system designed for analysis of organic substances in water samples, including drinking water, tap water, underground water, surface water as well as wastewater. RayKol ASPE Ultra automate liquid liquid extraction equipment can be used in the purification and enrichment of target compounds in water samples before analytical instrumentation, it automatically completes the steps of filtering, conditioning, loading, rinsing, drying, eluting and concentration, fully unattended extraction, avoiding exposure of hazardous chemicals to lab technicians, easy to build up a smart and safe laboratory environment.

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTIONSYSTEM FEATURES

Fully automatically preprocess water samples before analytical instrumentation

Good parallelism and reproducibility by independent pump-valve system and stable flow rate control

Avoid environmental interferences by a light-proof hood and airtight cavity design

Higly compatible with various applications, disk and column automated solid phase extraction available

Real-time monitoring, easy to access anytime

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM SPECIFICATIONS

Parameter

Specification

Product

ASPE Ultra 06

ASPE Ultra 08

Extraction channel

6

8

SPE disks

25mm, 47mm

25mm, 47mm

SPE cartridges

3mL, 6mL, 12mL

3mL, 6mL, 12mL

Solvent capacity

7

7

SPE column drying

Vacuum;

Vacuum;

nitrogen gas purge+vacuum

nitrogen gas purge+vacuum

Material contact with solvents

Teflon, glass

Teflon, glass

Waste discharge channel

3

3

(water sample waste; organic waste; organic waste contain fluorine)

(water sample waste; organic waste; organic waste contain fluorine)

Software interface

Built-in screen control

Built-in screen control

Dimension

66cm x 58cm x 76cm

66cm x 58cm x 76cm

Weight

50kg

50kg

Power supply

200 to 240V, 50/60Hz

200 to 240V, 50/60Hz

Power rate

450W

450W

Storage temperature

0 to 40°C

0 to 40°C

Storage humidity

20 to 85%

20 to 85%

Operating temperature

10 to 40°C

10 to 40°C

Operating humidity

20 to 80%

20 to 80%

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM APPLICATIONS

ASPE Ultra Automated Solid Phase Extraction System targets in trace organic compounds in all kinds of water, can be mainly applied in the fields and industries of:

✔ Disease control

✔ Environmental monitoring

✔ Municipal water

✔ Geology and mining

✔ Acadamic

✔ Hydrology

TYPES OF ANALYSIS USING ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM

Environmental sanitation - Standards for drinking water quality

Standard examination methods for drinking water

Environmental quality standard for atmosphere, water and soil - Ground water

Environmental quality standard for atmosphere, water and soil - Surface water

Standard of water quality examination methods for urban water supply

Urban water supply - Determination of stibium

Urban water supply - Determination of sodium, magnesium, calcium - Ion chromatography method

Urban water supply - Determination of organic phosphorous pesticides - GC method

Urban water supply - Determination of volatile organic compounds

We can offer kinds of total laboratory automation systemfor sale, if you have needs lab automationsystem, please contact us.



在线联系供应商

至: Raykol Group(XiaMen)Corp.,Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

NITROGEN EVAPORATION
NITROGEN EVAPORATION As one ofprofessional and experienced nitrogen evaporator suppliers, RayKol Automated nitrogen evaporation systemis specialized in simultaneous and...
IMD SERIES MICROWAVE DIGESTION SYSTEM
IMD SERIES MICROWAVE DIGESTION SYSTEM RayKol IMD series Microwave digestion systemis a microwave digestion instrument applicable in laboratories and various environments. Efficient and ...
LABORATORY CONSUMABLES
LABORATORY CONSUMABLES RayKol laboratory consumables and chemical suppliesprovide a wide selection of quality general lab consumables for equipment in analytical laborato...
AUTO EXTRA D10 AUTOMATED SOLID PHASE EXTRACTION SYSTEM
AUTO EXTRA D10 AUTOMATED SOLID PHASE EXTRACTION SYSTEM Auto Extra D10 Automated solid phase extraction discsis an automated sample pre-treatment instrument specialized in handling water samples for dete...
BLOCK DIGESTION
BLOCK DIGESTION RayKol block digestion systemutilizes graphite block to achieve encircled heating to completely digest samples based on the method of wet digestion...
供应产品

Same products

MONSA® DDAC-50
MONSA® DDAC-50 卖方: Guangzhou Monsa Chemical Co., Ltd INCI name: MONSA® DDAC-50 It functions by causing the cell membrane of bacteria to rupture...
MONSA® DCA-50
MONSA® DCA-50 卖方: Guangzhou Monsa Chemical Co., Ltd INCI name: disodium cocoampho diacetate Disodium cocoamphodiacetate for skinis a very mild amp...
MONSA® CTAC-50
MONSA® CTAC-50 卖方: Guangzhou Monsa Chemical Co., Ltd INCI name: Cetyl Trimethyl Ammonium Chloride Cetyl Trimethyl Ammonium Chloride is an ammonium ...
MONSA® CTAC-30
MONSA® CTAC-30 卖方: Guangzhou Monsa Chemical Co., Ltd INCI name: Cetyl Trimethyl Ammonium Chloride 30% Cetyltrimethyl ammonium chloride30% is mainly...
共轨喷油器
共轨喷油器 卖方: 德艾普(厦门)进出口有限公司 商品名称:柴油喷油器型号: 最小起订量:1 件 材质:钢 包装详情:纸箱包装 库存:有库存 品牌:CNDIP 质保:6个月