Finland dewar 50L for LN2 self pressured KGSQ liquid nitrogen cryogenic tank
As we all know, liquid nitrogen is a consumable low-temperature liquid that volatilizes when heated. Even if it is stored in a well-sealed liquid nitrogen tank, it will continue to decrease over time. Therefore, when professionals who need to freeze biological samples find that the liquid nitrogen in the tank is lower than a certain limit, they need to replenish liquid nitrogen in the tank in time to ensure that the samples can be stored normally.
However, most of the liquid nitrogen tanks used in laboratories are relatively large in volume and size. It is difficult to lift them manually and pour liquid nitrogen into the liquid nitrogen tank, and it is also easy to cause frostbite. Therefore, the self-pressurizing liquid nitrogen tankhas become a good helper for rehydration of laboratory liquid nitrogen tanks, solving the rehydration problem of laboratory users.
However, many users do not understand how to operate a self-pressurized liquid nitrogen tank. Today I will explain it in detail.
The self-pressurizing liquid nitrogen tank needs to be pressurized first, and the vent valve must be closed first to pressurize the liquid; then open the pressurizing valve to allow the nitrogen in the pressurizing tube to enter the inner tank, and then start the exchange cycle of nitrogen and liquid nitrogen. Until the pressure increases to ≥0.05MPa.
After the infusion is completed, first stop the pressurization, then stop draining the liquid nitrogen, and then open the pressure relief exhaust valve, that is, the vent valve.
The function of the vent valve is not only to relieve pressure and discharge residual liquid nitrogen, but also to prevent external heat and humid air from entering the pipeline and inner tank.
When the self-pressurized liquid nitrogen tank is stored statically, although there is no pressure, the liquid nitrogen naturally volatilizes, and a gas outlet is needed to release the nitrogen. The vent valve just acts as this "gas outlet". There is also the previously mentioned infusion to complete the pressure relief to avoid the entry of external air, etc.
The self-pressurizing liquid nitrogen tank complies with the national standard GB/T 14774-2012. It is a self-pressurizing liquid nitrogen container and the pressure must not exceed 0.1MPa. For the safety of users, most manufacturers set the pressure at no more than 0.09MPa and strive to be safe.
If the pressure = 0.09MPa, the self-pressurizing liquid nitrogen tank will automatically open the safety valve to release pressure to avoid dangerous incidents.
In addition, during normal use, the temperature difference between the inside and outside of the container is large, and the thermal equilibrium time is longer when adding liquid nitrogen. Use liquid nitrogen in advance to pre-cool it, and then add it gradually and slowly to prevent ice blockage!
If you have any needs, please contact KGSQ liquid nitrogen tank:
Email:
Official website:
Send product request
Other supplier products
Cambodia-nitrogen container storage KGSQ-insemination tank | Portable liquid nitrogen tanks, with their lightweight design and easy operation, are ideal for use in laboratories, healthcare organisations and t... | |
KGSQ cryogenic liquid nitrogen storage container_Liquid nitrogen tank manufacturer | What brand of liquid nitrogen tank is good? I believe that many people want to know this question. There are many manufacturers on the market, whic... | |
Zanzibar-liquid nitrogen dewar trolley-nitrogen dewar | In modern laboratories and animal husbandry, liquid nitrogen storage tanks are indispensable equipment, which are used to preserve precious biologi... | |
Bermuda-liquid nitrogen level monitors-Liquid level monitor | In the field of liquid nitrogen storage and application, accurate monitoring of liquid level changes is the key to ensuring experimental safety and... | |
Latvia liquid nitrogen tank for laboratory KGSQ laboratory dewar | In laboratories, the most common experimental objects are cells. The safety of cells is related to the accuracy of experimental results. Therefore,... |
Same products
Syria-liquid nitrogen container for cell storage-liquid nitrogen level gauge | Seller: Henan Tianzhidao Biological Technology Co., Ltd | Precise experimental conditions and safe sample storage are key elements for the smooth developme... | |
Italy-liquid nitrogen cell storage tank-liquid nitrogen tank level indicator | Seller: Henan Tianchi Instrument & Equipment Co., Ltd. | Precise experimental conditions and safe sample storage are key elements for the smooth developme... | |
Egypt-cryogenic cell storage-liquid nitrogen level monitors | Seller: Henan Tianzhidao Biological Technology Co., Ltd. | Precise experimental conditions and safe sample storage are key elements for the smooth developme... | |
Bolivia-laboratory dewar flask-pump liquid nitrogen | Seller: Henan Tianzhidao Biological Technology Co., Ltd | In the modern laboratory environment that pursues precision and efficiency, proper storage of sam... | |
Iraq-liquid nitrogen tank for laboratory-nitrogen pump | Seller: Henan Tianchi Instrument & Equipment Co., Ltd. | In the modern laboratory environment that pursues precision and efficiency, proper storage of sam... |