ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM

ASPE Ultra series Automated Solid Phase System is an automated sample preparation system designed for analysis of organic substances in water samples, including drinking water, tap water, underground water, surface water as well as wastewater. RayKol ASPE Ultra automate liquid liquid extraction equipment can be used in the purification and enrichment of target compounds in water samples before analytical instrumentation, it automatically completes the steps of filtering, conditioning, loading, rinsing, drying, eluting and concentration, fully unattended extraction, avoiding exposure of hazardous chemicals to lab technicians, easy to build up a smart and safe laboratory environment.

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTIONSYSTEM FEATURES

Fully automatically preprocess water samples before analytical instrumentation

Good parallelism and reproducibility by independent pump-valve system and stable flow rate control

Avoid environmental interferences by a light-proof hood and airtight cavity design

Higly compatible with various applications, disk and column automated solid phase extraction available

Real-time monitoring, easy to access anytime

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM SPECIFICATIONS

Parameter

Specification

Product

ASPE Ultra 06

ASPE Ultra 08

Extraction channel

6

8

SPE disks

25mm, 47mm

25mm, 47mm

SPE cartridges

3mL, 6mL, 12mL

3mL, 6mL, 12mL

Solvent capacity

7

7

SPE column drying

Vacuum;

Vacuum;

nitrogen gas purge+vacuum

nitrogen gas purge+vacuum

Material contact with solvents

Teflon, glass

Teflon, glass

Waste discharge channel

3

3

(water sample waste; organic waste; organic waste contain fluorine)

(water sample waste; organic waste; organic waste contain fluorine)

Software interface

Built-in screen control

Built-in screen control

Dimension

66cm x 58cm x 76cm

66cm x 58cm x 76cm

Weight

50kg

50kg

Power supply

200 to 240V, 50/60Hz

200 to 240V, 50/60Hz

Power rate

450W

450W

Storage temperature

0 to 40°C

0 to 40°C

Storage humidity

20 to 85%

20 to 85%

Operating temperature

10 to 40°C

10 to 40°C

Operating humidity

20 to 80%

20 to 80%

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM APPLICATIONS

ASPE Ultra Automated Solid Phase Extraction System targets in trace organic compounds in all kinds of water, can be mainly applied in the fields and industries of:

✔ Disease control

✔ Environmental monitoring

✔ Municipal water

✔ Geology and mining

✔ Acadamic

✔ Hydrology

TYPES OF ANALYSIS USING ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM

Environmental sanitation - Standards for drinking water quality

Standard examination methods for drinking water

Environmental quality standard for atmosphere, water and soil - Ground water

Environmental quality standard for atmosphere, water and soil - Surface water

Standard of water quality examination methods for urban water supply

Urban water supply - Determination of stibium

Urban water supply - Determination of sodium, magnesium, calcium - Ion chromatography method

Urban water supply - Determination of organic phosphorous pesticides - GC method

Urban water supply - Determination of volatile organic compounds

Now the price of total laboratory automation systemis reasonable, if you have needs to buy laboratory automationequipment, please leave us a message.



Send product request

To: Raykol Group(XiaMen)Corp.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

AUTO EVA 12 AUTOMATED PARALLEL NITROGEN EVAPORATOR
AUTO EVA 12 AUTOMATED PARALLEL NITROGEN EVAPORATOR RayKol Auto EVA 12 is a nitrogen blow-down automated evaporation system that provides automated evaporation of up to 12 samples in parallel with en...
RAYCURE QUECHERS CERAMIC HOMOGENIZERS
RAYCURE QUECHERS CERAMIC HOMOGENIZERS RayCure QuEChERS Ceramic homogenizerscan effectively increase sample preparation efficiency by their excellent homogenizing and dispersing abilitie...
SPE CARTRIDGES
SPE CARTRIDGES RayCure SPE series provides high-quality SPE cartridgesfor various types of solid phase extraction, including manifold, vacuum as well as automated...
VACUUM EVAPORATION
VACUUM EVAPORATION Raykol vacuum evaporation equipmentis an ideal solution for analytical laboratories. In the analysis of environmental pollutants and food safety, t...
ANALYTICAL LABORATORY EQUIPMENT
ANALYTICAL LABORATORY EQUIPMENT RayKol, as one of analytical lab equipment manufacturers, provides a wide range of analytical chemistry lab equipmentand laboratory apparatus used ...
All supplier products

Same products

CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS
CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS Seller: ZK Electronic Technology Co., Limited Part Number:CSD16301Q2 Description:CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS ...
CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF
CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF Seller: ZK Electronic Technology Co., Limited Part name:EEF-CX0J101R Description:CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V ...
Heavy Copper PCB Manufacturer
Heavy Copper PCB Manufacturer Seller: Xinfeng Huihe Circuits Co., Ltd. Heavy Copper PCB, pcb fabrication up to 12oz, large current, pcb circuitfabrication base material...
8 Layer ENIG Half Hole Custom PCB
8 Layer ENIG Half Hole Custom PCB Seller: Xinfeng Huihe Circuits Co., Ltd. Number of layers: 8 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 4/3mil Inner lay...
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board Seller: Xinfeng Huihe Circuits Co., Ltd. Number of layers: 4 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 6/4mil Inner lay...