ACREL MEDICAL IT ISOLATED POWER SYSTEM
Acrel medical isolated power supplysystems are mainly used in operating rooms, ICU/CCU intensive care units, premature infant care units, delivery rooms, hemodialysis centres, and emergency rooms. The hospital isolated power systemsprovide safe, reliable and continuous power distribution for important equipment in these places. They can realize the conditions of insulation, load and isolation transformer temperature of IT system. Real-time monitoring with functions such as system insulation fault circuit location and centralized monitoring of multiple systems.
Medical Isolated Power Supply System For Sale
Hospital isolated power systems provide safety, continuous and reliable power supply, real-time detection of the insulation state to the ground to ensure the life safety of patients. Insulation fault location, convenient maintenance.
Hospital Isolated Power Systems Data Sheet
|
Technical Parameters of AITR Series of Medical Isolation Transformer |
|||||
|
Type |
AITR10000 |
AITR8000 |
AITR6300 |
AITR5000 |
AITR3150 |
|
Insulation class |
H |
H |
H |
H |
H |
|
Protection class |
IP00 |
IP00 |
IP00 |
IP00 |
IP00 |
|
Power/voltage/ current |
|||||
|
Rated power |
10000VA |
8000VA |
6300VA |
5000VA |
3150VA |
|
Rated frequency |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
|
Rated input voltage |
AC230V |
AC230V |
AC230V |
AC230V |
AC230V |
|
Rated input current |
36A |
||||
|
Rated output voltage |
AC230V/115V |
AC230V/115V |
AC230V/115V |
AC230V/115V |
AC230V/115V |
|
Rated output current |
|||||
|
Inrush current |
<12In |
<12In |
<12In |
<12In |
<12In |
|
Leakage current |
<200μA |
<200μA |
<200μA |
<200μA |
<200μA |
|
No load input current |
|||||
|
No load output voltage |
235V±3% |
235V±3% |
235V±3% |
235V±3% |
235V±3% |
|
Short circuit voltage |
<6.9V |
<6.9V |
<6.9V |
<6.9V |
<7.5V |
|
General parameters |
|||||
|
Fuse wire |
80A |
63A |
50A |
35A |
25A |
|
Primary winding resistance |
<55mΩ |
<64mΩ |
<80mΩ |
<131 mΩ |
<245mΩ |
|
Secondary winding resistance |
<45mΩ |
<64mΩ |
<80mΩ |
<116 mΩ |
<228mΩ |
|
Iron loss |
<150W |
<105W |
<107W |
<77W |
<55W |
|
Copper loss |
<230W |
<200W |
<170W |
<125W |
<120W |
|
Efficiency |
>96% |
>96% |
>96% |
>96% |
>95% |
|
Maximum ambient temperature |
<40℃ |
<40℃ |
<40℃ |
<40℃ |
<40℃ |
|
No-load temperature rise |
<36℃ |
<33℃ |
<31℃ |
<26℃ |
<22℃ |
|
Full load temperature rise |
<65℃ |
<76℃ |
<67℃ |
<62℃ |
<55℃ |
|
Noise grade |
<40dB |
<40dB |
<40dB |
<40dB |
<40dB |
Isolated Power System Purpose
Medical isolated power panelsprovide safe, reliable and continuous power distribution for the important equipment at these locations:
Used for the transformation of TN system into IT system (ungrounded system)
Functions of real-time monitoring and fault alarming of the ground insulation resistance, transformer load current and transformer winding temperature of the monitored IT system
When the monitored IT system has an insulation fault, the medical isolation panel, hospital isolation panelcan initiate and generate the fault location signal to the system, and realize fault locating function with the help of the fault locator
Acrel isolation panel for operating roomscan remotely monitor the real-time operating conditions of up to 16 pieces of systems, and the main interface intuitively displays whether the access system communication is intact
Medica/Hospital Isolated Power Systems FAQs
What is hospital isolated power system?
It is an isolated power system operating roomthat conducts insulation monitoring and fault determination of the power distribution system, to further provide safe, reliable and continuous power distribution.
What are functions of medical isolated power panels?
What's the consists of medical isolated power supply system?
What are the applications of hospital isolated power systems?
If you want to know more kinds of split current transformer, please visit our website.
Send product request
Other supplier products
| POWER QUALITY DEVICE | Acrel power quality device is mainly used for power supply and distribution equipment at the user end, and provides power quality improvement equip... | |
| ACREL AKH-0.66 / K SPLIT CORE CURRENT TRANSFORMER | Acrel AKH-0.66/K series current transformer split coreare mainly used in reconstructing projects of urban and rural power grids. The split core cur... | |
| DATA CENTER MONITOR | Acrel based on customer needs, we integrate the characteristics of data center operation and maintenance, from the bottom monitoring of equipment t... | |
| POWER QUALITY DEVICE | Acrel power quality device is mainly used for power supply and distribution equipment at the user end, and provides power quality improvement equip... | |
| MICROGRID ENERGY MANAGEMENT SYSTEM | Under the threat of global energy shortage and the urgency to curb environmental pollution, the demand for energy conservation and emission reducti... |
Same products
| Air insulated Dry type transformer VPI | Seller: TAILI ELECTRIC CO.,LTD. | Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des... | |
| Cast Resin Dry Type Transformer with Cooling Fan | Seller: TAILI ELECTRIC CO.,LTD. | Cast Resin Dry Type Transformer with Cooling Fan Taili’s advanced epoxy resin casting proc... | |
| 1250kVA Dry type Transformer for Bangladesh | Seller: TAILI ELECTRIC CO.,LTD. | 1250kVA Dry type Transformer for Bangladesh Taili's advanced epoxy resin casting process ensures... | |
| 35kV Dry-type transformer with OLTC | Seller: TAILI ELECTRIC CO.,LTD. | 35kV Dry-type transformer with OLTC Taili's35kV Dry-type Transformer with OLTC (On-Load Tap Chan... | |
| Cast Resin Dry Type Transformer | Seller: TAILI ELECTRIC CO.,LTD. | Cast Resin Dry Type Transformer IEC/ANSICast Resin TransformersfromTAILI Electric, is difference... |