AKH-0.66 / K Split Core Current Transformer
Acrel AKH-0.66/K series split core current transformerare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. Thiscurrent transformer split corematcheswith relay protection, measuring, and metering equipment.
Without removal of primary bus
Be operated with electricity
Save manpower
Varies dimension optional
AKH-0.66/K Split Core Type Current Transformers Parameters
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
Type |
Ratio(A) |
Class |
Burden(VA) |
K-30x20 |
20-75/1 |
1 |
|
100-150/5(1) |
1 |
1 |
|
200/5(1) |
1 |
||
250-300/5(1) |
|||
350-400/5(1) |
|||
K-60x40 |
250-300/5(1) |
1 |
|
350-400/5(1) |
|||
500-800/5(1) |
|||
1000-1250/5(1) |
5 |
||
1500-2000/5(1) |
10 |
||
K-80x40 |
350/5(1) |
1 |
|
350-450/5(1) |
|||
500-800/5(1) |
5 |
||
1000-2000/5(1) |
10 |
||
2500-3000/5(1) |
10 |
||
K-80x50 |
250-300/5(1) |
1 |
|
400-450/5(1) |
|||
500-800/5(1) |
|||
1000/5(1) |
5 |
||
K-80x80 |
250-300/5(1) |
1 |
|
400-450/5(1) |
|||
500-800/5(1) |
|||
1000/5(1) |
5 |
||
K-100x40 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-120x60 |
400-450/5(1) |
||
500-800/5(1) |
5 |
||
1000-2000/5(1) |
10 |
||
2500-5000/5(1) |
10 |
||
K-120x80 |
500-800/5(1) |
||
1000-1200/5(1) |
5 |
||
1250-1500/5(1) |
|||
K-130x40 |
1000-2000/5(1) |
10 |
|
2500-5000/5(1) |
10 |
||
K-130x60 |
1000-2000/5(1) |
10 |
|
2500-6000/5(1) |
15 |
||
K-140x60 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-160x80 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-200x80 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-Φ20 |
100A/20mA |
1 |
15Ω |
K-Φ30 |
200A/20mA |
10Ω |
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Current TransformerDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
Acrel AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Core Current Transformer Installation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
Send product request
Other supplier products
ACREL ADW300 WIRELESS ENERGY METER | Acrel ADW300 wireless smart energy meter is mainly used to measure three-phase active electric energy of the low-voltage networks. With RS485 commu... | |
ENERGY MANAGEMENT DEVICES | Acrel Power Meters and Energy Management system is in accordance with the needs of users, in accordance with the standard specifications of the dis... | |
ELECTRICAL MONITORING & PROTECTION DEVICE | Acrel electrical overload protection devicesprovide solutions for 0.4kv-35kv power distribution system, which include programmable panel energy met... | |
ACREL AID150 ALARM AND DISPLAY DEVICE | The AID150 insulation monitoring device schneideris designed for visual and audible indication of alarm messages from ACREL medical intelligent ins... | |
POWER SENSOR | Acrel power transduceris designed for industrial electrical measurement of low voltage system, include current transformer, hall effect current sen... |
Same products
CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS | Seller: ZK Electronic Technology Co., Limited | Part Number:CSD16301Q2 Description:CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS ... | |
CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF | Seller: ZK Electronic Technology Co., Limited | Part name:EEF-CX0J101R Description:CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V ... | |
Heavy Copper PCB Manufacturer | Seller: Xinfeng Huihe Circuits Co., Ltd. | Heavy Copper PCB, pcb fabrication up to 12oz, large current, pcb circuitfabrication base material... | |
8 Layer ENIG Half Hole Custom PCB | Seller: Xinfeng Huihe Circuits Co., Ltd. | Number of layers: 8 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 4/3mil Inner lay... | |
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board | Seller: Xinfeng Huihe Circuits Co., Ltd. | Number of layers: 4 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 6/4mil Inner lay... |