AKH-0.66 / K Split Core Current Transformer
Acrel AKH-0.66/K series split core current transformerare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. Thiscurrent transformer split corematcheswith relay protection, measuring, and metering equipment.
Without removal of primary bus
Be operated with electricity
Save manpower
Varies dimension optional
AKH-0.66/K Split Core Type Current Transformers Parameters
|
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
|
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
|
Type |
Ratio(A) |
Class |
Burden(VA) |
|
K-30x20 |
20-75/1 |
1 |
|
|
100-150/5(1) |
1 |
1 |
|
|
200/5(1) |
1 |
||
|
250-300/5(1) |
|||
|
350-400/5(1) |
|||
|
K-60x40 |
250-300/5(1) |
1 |
|
|
350-400/5(1) |
|||
|
500-800/5(1) |
|||
|
1000-1250/5(1) |
5 |
||
|
1500-2000/5(1) |
10 |
||
|
K-80x40 |
350/5(1) |
1 |
|
|
350-450/5(1) |
|||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-3000/5(1) |
10 |
||
|
K-80x50 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-80x80 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-100x40 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-120x60 |
400-450/5(1) |
||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-5000/5(1) |
10 |
||
|
K-120x80 |
500-800/5(1) |
||
|
1000-1200/5(1) |
5 |
||
|
1250-1500/5(1) |
|||
|
K-130x40 |
1000-2000/5(1) |
10 |
|
|
2500-5000/5(1) |
10 |
||
|
K-130x60 |
1000-2000/5(1) |
10 |
|
|
2500-6000/5(1) |
15 |
||
|
K-140x60 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-160x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-200x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
|
K-Φ30 |
200A/20mA |
10Ω |
|
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Current TransformerDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
Acrel AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Core Current Transformer Installation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
Send product request
Other supplier products
| ACREL ADW300 WIRELESS ENERGY METER | Acrel ADW300 wireless smart energy meter is mainly used to measure three-phase active electric energy of the low-voltage networks. With RS485 commu... | |
| ISOLATED POWER SYSTEMS | Acrel Isolated power monitoring and control systemare mainly used in the medical and industrial sectors. The medical IT system is mainly designed f... | |
| SMART GATEWAY | Acrel smart geteway currently include AWT100 wireless communication terminal, ANet smart gateway. these products mainly realizes the function of ... | |
| POWER QUALITY DEVICE | Acrel power quality device is mainly used for power supply and distribution equipment at the user end, and provides power quality improvement equ... | |
| ACREL ADW SERIES IOT POWER METER | Acrel ADW series energy meter using iotcompared with smart energy meter has the biggest advantage is that it can be controlled by wireless communic... |
Same products
| Stainless Steel Pallet Truck | Seller: 869821 | Stainless Steel Pallet Truck Stainless Steel Pallet Truck Advantages: • Superior co... | |
| hsz type chain block | Seller: 869821 | hsz type chain block The HSZ type chain block is a manually operated lifting device designed... | |
| 15 Inch Capacitive Touch Screen Panel for Medical & Multi-Application Equipment | Seller: SEMIJEI TECHNOLOGY LTD | 15 Inch Capacitive Touch Screen Panel for Medical & Multi-Application Equipment 15 Inch Ca... | |
| Custom Size 11.6 Inch Circular Shape Touch Screen With ILITEK Controller | Seller: SEMIJEI TECHNOLOGY LTD | Custom Size 11.6 Inch Circular Shape Touch Screen With ILITEK Controller Semijei-Tech's11.6 in... | |
| 10.6 Inch Custom Shape Touch Screen With Multi-Touch for Commercial Systems | Seller: SEMIJEI TECHNOLOGY LTD | Semijei-Tech's10.6 inch custom shape touch screenis a projected capacitive touch panel develope... |