AKH-0.66 / K Split Core Current Transformer
Acrel AKH-0.66/K series split core current transformerare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. Thiscurrent transformer split corematcheswith relay protection, measuring, and metering equipment.
Without removal of primary bus
Be operated with electricity
Save manpower
Varies dimension optional
AKH-0.66/K Split Core Type Current Transformers Parameters
|
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
|
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
|
Type |
Ratio(A) |
Class |
Burden(VA) |
|
K-30x20 |
20-75/1 |
1 |
|
|
100-150/5(1) |
1 |
1 |
|
|
200/5(1) |
1 |
||
|
250-300/5(1) |
|||
|
350-400/5(1) |
|||
|
K-60x40 |
250-300/5(1) |
1 |
|
|
350-400/5(1) |
|||
|
500-800/5(1) |
|||
|
1000-1250/5(1) |
5 |
||
|
1500-2000/5(1) |
10 |
||
|
K-80x40 |
350/5(1) |
1 |
|
|
350-450/5(1) |
|||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-3000/5(1) |
10 |
||
|
K-80x50 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-80x80 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-100x40 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-120x60 |
400-450/5(1) |
||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-5000/5(1) |
10 |
||
|
K-120x80 |
500-800/5(1) |
||
|
1000-1200/5(1) |
5 |
||
|
1250-1500/5(1) |
|||
|
K-130x40 |
1000-2000/5(1) |
10 |
|
|
2500-5000/5(1) |
10 |
||
|
K-130x60 |
1000-2000/5(1) |
10 |
|
|
2500-6000/5(1) |
15 |
||
|
K-140x60 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-160x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-200x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
|
K-Φ30 |
200A/20mA |
10Ω |
|
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Current TransformerDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
Acrel AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Core Current Transformer Installation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
在线联系供应商
Other supplier products
| DATA CENTER MONITOR | Acrel based on customer needs, we integrate the characteristics of data center operation and maintenance, from the bottom monitoring of equipment t... | |
| POWER SENSOR | Acrel power sensor is designed for industrial electrical measurement of low voltage system, include high precision current transformer, hall effect... | |
| AKH-0.66 / K Split Core Current Transformer | Acrel AKH-0.66/K series split core current transformerare mainly used in reconstructing projects of urban and rural power grids. The split core cur... | |
| SMART GATEWAY | Acrel smart geteway currently include AWT100 wireless communication terminal, ANet smart gateway. these products mainly realizes the function of th... | |
| POWER QUALITY DEVICE | Acrel power quality equipment is mainly used for power supply and distribution equipment at the user end, and provides power quality improvement eq... |
Same products
| HM B200/B210 Series | 卖方: BEIJING HIGHMESH INFORMATION TECHNOLOGY CO.,LTD. | HM B200/B210 Series USRP B200/B210 Product Overview The B200 and B210 hardwarecovers RF frequen... | |
| HM-B210(Single-Board) | 卖方: BEIJING HIGHMESH INFORMATION TECHNOLOGY CO.,LTD. | HM-B210(Single-Board) Description TheB210is a highly integrated Universal Software Radio Periph... | |
| Busbar systems | 卖方: Jinan Dema Electric Co., Ltd. | Busbar systems Busbar Systems for Plant Reliable Industrial Power Distribution Solutions for Fa... | |
| Aluminium Cable Festoon System | 卖方: Jinan Dema Electric Co., Ltd. | Aluminium Cable Festoon System The company's newly developed DM-CL Aluminium Cable Festoon Syste... | |
| Open copperhead conductor Bar | 卖方: Jinan Dema Electric Co., Ltd. | Open copperhead conductor Bar DMGH Series Open Copperhead Conductor Bar Reliable Power Supply S... |