Thrombite™ Clot Retriever Device

OVERVIEW

Thrombite™ Clot Retriever Device

HELICAL OPEN-SIDE STRUCTURE

HIGHER ACUTE RECANALIZATION RATE

The Thrombite™ endovascular clot retrieval, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

PRODUCT FEATURES

HELICAL OPEN-SIDE STRUCTURE

enables Thrombite™ clot retrieverto efficiently entwine and clamp the clot

assures clot retention for confident removal and revascularization

OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

increases contact surface with thrombus and maximizes clot integration

EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

optimizes clot retention during smooth navigation through the tortuous anatomies

Radiopaque markers on the distal end of the device increase device visibility

3 markers for the sizes with 3.0 and 4.0mm diameter

4 markers for the sizes with 5.0 and 6.0mm diameter

Advanced stent surface treatment process

RADIAL FORCE

High radial force is designed for clot integration at the initial stage of stent expansion

Low radial force at nominal stent diameter ensures atraumatic retrieval

RADIAL FORCE

How a Stent Retriever ProcedureIs Performed

Stent retrieverprocedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retrieval devicewill be extracted along with the clot and finally leave your body.

ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE

STENT RETRIEVAL DEVICE STRUCTURE

Thrombite™

Product code

Diameter D(mm)

Recommended Vessel Diameter(mm)

Recommende Microcatheter ID (inch)

Working Length A(mm)

Stent Length B(mm)

System Length(mm)

  1. Max.

3MM

CRD-3-15

3

3

15

27

1900

CRD-3-20

3

3

20

32

1900

CRD-3-25

3

3

25

37

1900

CRD-3-30

3

3

30

42

1900

4MM

CRD-4-15

4

2

4

15

27

1900

CRD-4-20

4

2

4

20

32

1900

CRD-4-25

4

2

4

25

37

1900

CRD-4-30

4

2

4

30

42

1900

5MM

CRD-5-15

5

5

15

27

1900

CRD-5-20

5

5

20

32

1900

CRD-5-25

5

5

25

37

1900

CRD-5-30

5

5

30

42

1900

6MM

CRD-6-15

6

3

15

27

1900

CRD-6-20

6

3

20

32

1900

CRD-6-25

6

3

25

37

1900

CRD-6-30

6

3

30

42

1900

INDICATIONS

Thrombite™ Clot Retriever Device

The Thrombite™ clot retrieval deviceis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

ZyloxTonbridgeMedical highlights the corporate social responsibility and mission, and boosts the innovation and technological development by taking active part in the combination of scientific innovation with medical engineering.



Send product request

To: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Thrombite™ Clot Retriever Device
Thrombite™ Clot Retriever Device OVERVIEW Thrombite™ Clot Retriever Device HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite™ endovascular ...
Snare Retrieval Kit for IVC Filter
Snare Retrieval Kit for IVC Filter Snare Retrieval Kit for IVC Filter We are one of leading neurovascular medical device companies in the peripheral and neurovascular intervention...
Peripheral Drug-eluting Stent System
Peripheral Drug-eluting Stent System OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting stent in the...
NEURO INTERVENTIONS
NEURO INTERVENTIONS NEURO INTERVENTIONS One of the top neurovascular device companiesin China The pursuit of excellence is the best expression of care for life and o...
PTA Balloon Catheter
PTA Balloon Catheter EASY ACCESS TO THE MOST CHALLENGING ANATOMIES The PTA cathetersare non-reusable semi-compliant coaxial design catheters consisting of an OTWballoo...
All supplier products

Same products

Thrombite™ Clot Retriever Device
Thrombite™ Clot Retriever Device Seller: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. OVERVIEW Thrombite™ Clot Retriever Device HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECAN...
Market Status Of China's Mold Manufacturing Industry
Market Status Of China's Mold Manufacturing Industry Seller: Taizhou Huangyan Fow Mould CO., LTD In recent years, due to the continuous improvement of China's industrialization, China has become...
Stamping Mold Parts
Stamping Mold Parts Seller: Dongguan City Fangling Precision Mould Co., LTD. Stamping — also called pressing — involves placing flat sheet metal, in either coil o...
Nylon 66 PA66 Heat Stabilized (A2006X01, A2016X01) for Engineering Plastics
Nylon 66 PA66 Heat Stabilized (A2006X01, A2016X01) for Engineering Plastics Seller: Suzhou Anmei Material Technology Co., Ltd Nylon66 PA66 Heat Stabilized Description Nylon66 PA66 Heat Stabilized a high temperature nylon m...
Furniture UV Coating Machine Line for sale
Furniture UV Coating Machine Line for sale Seller: Suzhou Kisinhom Machinery Co., Ltd. The uv coater machinecoats the rolled substrate with a layer of glue, paint or ink with a specifi...