.

Dengue Test Kit

In vitro diagnostic assayshave been widely used in clinical testing. With the development of science and technology of ivd diagnostics, in vitro diagnostic reagents are becoming more and more widely used.

Dengue virus is an enveloped, single-stranded, positive-sense RNA virus that comprises four related but distinct serotypes (Den 1, 2, 3, and 4). The virus is transmitted by mosquitoes of the daytime-biting Stegomyia family, principally Aedes aegypti and Aedes albopictus. Today, more than 2.5 billion people living in the areas of tropical Asia, Africa, Australia and the Americas are at risk for dengue infection.

An estimated 100 million cases of dengue fever and 250,000 cases of life-threatening dengue hemorrhagic fever occur annually on a worldwide basis. Serological detection is a common method for the diagnosis of infection with dengue virus. IgM anti-dengue virus starts to appear at 3 days after initial exposure and remains in circulation for about 30- 60 days. IgG anti-dengue virus is raised at around 7 days, peaks at 2-3 weeks and persists for the duration of life4-6. Detection of antigens released during virus replication in the infected patient show very promising results; it enables diagnosis from the first day after the onset of fever up to day 9 once the clinical phase of the disease is over, thus, allowing early detection and prompt treatment.

Features Of Dengue Test Kit

The Dengue Ag NS1-IgM/IgG rapid test detects IgG and IgM anti-dengue virus and circulating dengue antigen in one test within 20 minutes. This dengue duo rapid test kitis user-friendly, does not require cumbersome laboratory equipment and requires minimal staff training.

The Dengue NS1+IgM/IgG Combo rapid test is a lateral flow immunoassay for the simultaneous detection and differentiation of IgG anti– dengue virus, IgM anti-dengue virus and dengue antigen (Dengue Ag) in human serum, plasma or whole blood. It is intended to be used by professionals as a screening test and as an aid in the diagnosis of infection with dengue virus. Any reactive specimen with the Dengue Ag NS1-IgM/IgG rapid test must be confirmed with alternative testing method(s).

Precautions Of Dengue Test Kit

  1. ns1 kit.

  1. dengue test kit procedureis completed, dispose of specimens carefully after autoclaving them for at least one hour. Alternatively, they can be treated with 0.5 to 1% solution of sodium hypochlorite for one hour before disposal.

  1. dengue duo kitreagents are being handled.

  1. Excess sample volume (>5µL) can give false positives

If you want to buy dengue test kitor know dengue ns1 price, please contact us.



在线联系供应商

至: Hainan Medikament Trading Co., Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Recombinant Myoglobin Protein
Recombinant Myoglobin Protein Recombinant Myoglobin Proteinis suitable for use as a standard in immunoassay, immunogen for antisera production, and tracer for iodination. Each l...
IVD Test Kit
IVD Test Kit We provide one step rapid test IVD for various infectious diseases, such as colloidal gold method rapid test , ebola test kit, hepatitis C test kit...
Ebola Test Kit
Ebola Test Kit Rapid test for ebola(Colloidal gold method) is intended for the qualitative detection of ebola antigens from Nose swabs. This rapid test for ebola ...
Ebola Test Kit
Ebola Test Kit Ebola Rapid Test Kit (Colloidal gold method) is intended for the qualitative detection of ebola antigens from Nose swabs. This rapid test for ebola...
Purified D-dimmer Antigen
Purified D-dimmer Antigen The Purified d dimer antigenis suitable for use as a standard in immunoassay, immunogen for antisera production, and tracer for iodination. Each la...
供应产品

Same products

Common Rail injector control valve F00V C01 365 & Common Rail injector control valve F00V C01 368
Common Rail injector control valve F00V C01 365 & Common Rail injector control valve F00V C01 368 卖方: zhonglutong Common Rail injector control valve F00V C01 365 Common Rail injector control valve F00V C01 368 C...
Common Rail injector control valve F00V C01 362 & Common Rail injector control valve F00V C01 363
Common Rail injector control valve F00V C01 362 & Common Rail injector control valve F00V C01 363 卖方: zhonglutong Common Rail injector control valve F00V C01 362 Common Rail injector control valve F00V C01 363 C...
Common Rail injector control valve F00V C01 358 & Common Rail injector control valve F00V C01 359
Common Rail injector control valve F00V C01 358 & Common Rail injector control valve F00V C01 359 卖方: zhonglutong Common Rail injector control valve F00V C01 358 Common Rail injector control valve F00V C01 359 C...
Common Rail injector control valve F00V C01 355 & Common Rail injector control valve F00V C01 356
Common Rail injector control valve F00V C01 355 & Common Rail injector control valve F00V C01 356 卖方: zhonglutong Common Rail injector control valve F00V C01 355 Common Rail injector control valve F00V C01 356 C...
Common Rail injector control valve F00V C01 352 & Common Rail injector control valve F00V C01 353
Common Rail injector control valve F00V C01 352 & Common Rail injector control valve F00V C01 353 卖方: zhonglutong Common Rail injector control valve F00V C01 352 Common Rail injector control valve F00V C01 353 C...