Schneider Electric Altistart 01 soft starter ATSU01N232LT
Schneider Electric Altistart 01 soft starter ATSU01N232LT
soft starter for asynchronous motor,Altistart U01, TeSys U, ATSU01,32A, 200 to 480V, 7.5 to 15kW
Please contact me get more information
VK/Whatsapp/Telegram:
Website:
Main
Range of Product Altistart U01 and TeSys U
Product or Component Type Soft starter
Product destination Asynchronous motors
Product Specific Application Simple machine
Device short name ATSU01
Phase 3 phase
[Us] rated supply voltage 200...480 V - 10...10 %
Motor power kW 15 kW, 3 phase 400 V
7.5 kW, 3 phase 230 V
Maximum Horse Power Rating 10 hp, 3 phase 230 V
20 hp, 3 phase 460 V
IcL starter rating 32 A
Utilisation category AC-53B EN/IEC 60947-4-2
Current consumption 100 mA
Type of start Start with voltage ramp
Power dissipation in W 2.5 W at full load and at end of starting
322.5 W in transient state
Please contact me get more information
VK/Whatsapp/Telegram:
Website:
Complementary
Assembly style With heat sink
Function Available Integrated bypass
Supply voltage limits 180…528 V
Supply frequency 50...60 Hz - 5...5 %
Network Frequency 47.5...63 Hz
Output voltage <= power supply voltage
[Uc] control circuit voltage 24 V DC +/- 10 %
Starting time Adjustable from 1 to 10 s
1 s / 50
10 s / 5
5 s / 10
Deceleration time symb Adjustable from 1 to 10 s
Starting torque 30...80 % of starting torque of motor connected directly on the line supply
Discrete input type Logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Environment
Electromagnetic compatibility Conducted and radiated emissions level B CISPR 11
Conducted and radiated emissions level B IEC 60947-4-2
Damped oscillating waves level 3 IEC 61000-4-12
Electrostatic discharge level 3 IEC 61000-4-2
EMC immunity EN 50082-1
EMC immunity level B EN 50082-2
Harmonics level 3 IEC 1000-3-2
Harmonics level 3 IEC 1000-3-4
Immunity to electrical transients level 4 IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3
Voltage/current impulse level 3 IEC 61000-4-5
Conducted and radiated emissions level 3 IEC 61000-4-6
Immunity to conducted interference caused by radio-electrical fields level 4 IEC
Please contact me get more information
VK/Whatsapp/Telegram:
Website:
Schneider Electric Altistart 01 soft starter ATSU01N222LT
Schneider Electric Altistart 01 soft starter ATSU01N212LT
Schneider Electric Altistart 01 soft starter ATSU01N209LT
Schneider Electric Altistart 01 soft starter ATSU01N206LT
Schneider Electric Altistart 01 soft starter ATS01N232QN
Schneider Electric Altistart 01 soft starter ATS01N222QN
Schneider Electric Altistart 01 soft starter ATS01N212QN
Schneider Electric Altistart 01 soft starter ATS01N209QN
Schneider Electric Altistart 01 soft starter ATS01N206QN
Schneider Electric Altistart 01 soft starter ATS01N112FT
Schneider Electric Altistart 01 soft starter ATS01N109FT
Schneider Electric Altistart 01 soft starter ATS01N106FT
Schneider Electric Altistart 01 soft starter ATS01N103FT
Schneider Electric Altistart 22 soft starter ATS22C59S6U
Schneider Electric Altistart 22 soft starter ATS22C48S6U
Schneider Electric Altistart 22 soft starter ATS22C41S6U
Schneider Electric Altistart 22 soft starter ATS22C32S6U
Schneider Electric Altistart 22 soft starter ATS22C25S6U
Schneider Electric Altistart 22 soft starter ATS22C21S6U
Schneider Electric Altistart 22 soft starter ATS22C17S6U
Schneider Electric Altistart 22 soft starter ATS22C14S6U
Schneider Electric Altistart 22 soft starter ATS22C11S6U
Schneider Electric Altistart 22 soft starter ATS22D88S6U
Schneider Electric Altistart 22 soft starter ATS22D75S6U
Schneider Electric Altistart 22 soft starter ATS22D62S6U
Schneider Electric Altistart 22 soft starter ATS22D47S6U
Schneider Electric Altistart 22 soft starter ATS22D32S6U
Schneider Electric Altistart 22 soft starter ATS22D17S6U
Other supplier products
|
Eaton DH1-357D5FB-C54C PowerXL DH1 HVAC variable frequency |
Eaton DH1-357D5FB-C54C PowerXL DH1 HVAC variable frequency Eaton PowerXL DH1 VFD,7.5A,5 HP,3.7 kW,525 - 600 Vac,KEYPAD,EMC Filter,DC Choke,Brake C... |
|
Schneider Electric XALFZF8 power socket XALF with protective shutter - grey |
Schneider Electric XALFZF8 power socket XALF with protective shutter - grey Schneider Electric XALFZF8 power socket XALF with protective shutter -... |
|
Bently Nevada Extension Cable |
Bently Nevada Extension Cable Please contact me get more information |
|
ABB Bailey Analog Input Module IMASI13 |
ABB Bailey Analog Input Module IMASI13 Monitoring process variables such as temperature, pressure, flow, and level Interfacing with sensors and tr... |
|
SCHNEIDER discrete input module 140DDI35300 |
SCHNEIDER discrete input module 140DDI35300 Range of Product Modicon Quantum automation platform Product or Component TypeLow voltage dc discrete ... |
供应产品