EVI Heat Pump (12KW/19KW)
EVI Air to Water Heat Pump Overview
- This air source heat pump is using Scroll EVI Copeland compressor, and EVI technology to make strong capacity to heating when cold ambient,a digital controller to feel and defrost.
- EVIair source heat pump12kW 19kW to pass EN14825 ERP energy level test, all SCOP: A+, and passed TUV CE certificate.
- We using monobloc design to easy install, and high-efficiency heat exchanger, inside directly building high pressure, low pressure sensor to easily read and balance inside safe pressure.
- One key touch controller auto running connect 16PCS heat pump by modular, can control by Mobile or computer from Connect R485S port on the PCB panel.
![EVI Heat Pump
EVI Heat Pump (12KW/19KW)]()
![EVI Heat Pump
EVI Heat Pump (12KW/19KW)]()
Vertical design & low noiselow temperature heat pumpis best to heat pump for cold winter heating room choose.SUNCHIEVI HeatPump Unit: This unit is mainly used for heating in low-temperature area. The unit consists of outdoor and indoor units. The main components of the outdoor unit include a compressor, evaporator, fan, electronic expansion valve, steam separator and so on. The main components of the indoor unit include a condenser, liquid storage device, and pump (optional built-in). The outdoor unit and the indoor unit are connected by two copper tubes. This unit is suitable to be used in the area where the temperature is above -25℃. It can be used for heating and make hot water. The temperature range of hot water the unit can make is from 30℃ to 60℃. The main engine exhausts the wind sideward.Main Configuration:Copeland compressor, intelligent electronic expansion valve, high efficiency tube heat exchanger, SANHUA four-way valve, low noise and efficient internal rotor motor, 9.52 inner thread copper tube, blue hydrophilic ripple fin, and Wilo water pump (optional built-in).
Main Features of EVI Air Source Heat Pump:
1. Complete Freeze-proofing: According to the characteristics of low temperature water freezing, the waterway is separated from the main engine perfectly, and is installed in the indoor unit to solve the freezing problem of waterways thoroughly.2. High Efficiency and Ultra Wide Range Operation: The unit can be used in the area where the ambient temperature is as low as -25℃ to 45℃. Under the environment of -15℃, COP can reach 2.52 when the unit is used for radiant floor heating ( leaving water temperature is 45℃).3. Perfect Protection System: Four water system protection systems, five power supply system protection systems, nine heating system protection systems, control system intelligent detection systems, intelligent alarm, and 360°protection unit.
Low Temperature Heat Pump Specification
| EVIAirHeatPumpWaterHeater(working-25Cwinter) |
| Model |
|
KFXRS-12IID |
KFXRS-19IID |
| HP |
3P |
5P |
| Powersupply |
Type |
380V3N~50Hz |
| Ratedheatingcapacity |
kW |
11 |
18 |
| Ratedheatinginputpower |
kW |
2.6 |
4.3 |
| Ratedheatinginputcurrent |
A |
4.9 |
8.1 |
| COP |
w/w |
4.2 |
4.2 |
| Maxinputpower |
kW |
4.3 |
6.7 |
| Maxinputcurrent |
A |
8.1 |
12.7 |
| Ratedwaterflowvolume |
m3/h |
1.9 |
3.1 |
| Ratedhotwateryield |
L/h |
235L |
385L |
| Refrigerantchargevolume |
kg |
3.5 |
4.5 |
| Refrigerant |
Type |
R407C |
| Heatinghotwatertemp.rang |
℃ |
30℃~55℃ |
| Workingambienttemp. |
℃ |
-25℃~45℃ |
| Compressor |
Type |
Copeland |
| Fanmotor |
Type |
ACmotor,3-speedfan |
| Throttleway |
Type |
Electronicexpansionvalve |
| ElectronicComponent |
Type |
SchneiderACcontactor |
| Pressuredevice |
Type |
Built-inhighandlowpressuresensor |
| Watersideheatexchanger |
Type |
Highefficientheatexchanger |
| Airsideheatexchanger |
Type |
Hydrophilicaluminumfinheatexchanger |
| Noise |
dB(A) |
53 |
55 |
| N.W/G.W |
Kg |
103/111 |
118/134 |
| Connectpipesize |
inch |
Rc1"/DN25 |
| UnitSize(L*W*H) |
mm |
1040*420*865 |
1040*420*1380 |
| Thedataintheabovetabletestasfollowing:Heatingtestcondition:ambienttemp.(DB/WB):20℃/15℃,initialwatertemp.:15℃,outputwatertemp.:55℃;Note:thedatainthistableareforreferenceonly,pleasefollowingthenameplateparameterofthisproduct |
![EVI Heat Pump (12KW/19KW)]()
![EVI Heat Pump (12KW/19KW)]()
![EVI Heat Pump (12KW/19KW)]()
![EVI Heat Pump (12KW/19KW)]()
Other supplier products
|
|
3.5 Ton Heat Pump Split System |
is divided into indoor unit and outdoor unit. The outdoor unit is a condensing unit. It is the same thing as an air conditioner. It is only a fan.... |
|
|
DC Inverter Heat Pump Hot Water Heater |
DC inverter home using hot water heat pump boiler, 5kW with 200L tank produce 55℃ hot water, max 60 hot water, 220V ~50Hz/60Hz power supply.
DC Inv... |
|
|
Solar Air Conditioner |
Our SUNCHI New Energy produce 2 types solar powered split system air conditioner- DC48V 100% solar air conditioner and ACDC hybrid solar 30kw air c... |
|
|
Hybrid Solar Air Conditioner Overview |
Cooling capacity 9000BTU/12000BTU/18000BTU/24000BTUInside building digital calculator to priority biggest using DC power, auto balance 220V city gr... |
|
|
3.5 Ton Heat Pump Split System |
is divided into indoor unit and outdoor unit. The outdoor unit is a condensing unit. It is the same thing as an air conditioner. It is only a fan.... |
供应产品
Same products