aneko 3-way solenoid valve-M00DU SERIES
Feature
- Capable of preventing changes in operation by power failure.
- Should power failure occur after the start of operation, the valve does not change its operating position. Therefore, accidents due to power failure can be prevented.
- No loss in electric power.
- Very economical since the valves are designed to reduce power consumption to about 1/3 that with our former products.
- Economical and free from anxiety.
- Quite safe without burnout and insulation degradation as the temperature rise of the coil is very low.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20~60℃
AMBIENT TEMPERATURE
-20~60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE, Cv. FLOW FACTOR
ORIFICE TYPE |
ORIFICE SIZE |
WORKING PRESSURE |
Cv. FLOW FACTOR |
BLANK |
1.6 |
0~0.99MPa |
0.084 |
1 |
3.0 |
0~0.4MPa |
0.22 |
ELECTRICAL SPECIFICATIONS
AC |
DC |
||
V/Hz |
A |
V |
A |
100/50 |
0.052 |
24 |
0.260 |
100/60 |
0.052 |
48 |
0.120 |
110/60 |
0.058 |
100 |
0.062 |
200/50 |
0.040 |
110 |
0.067 |
200/60 |
0.040 |
125 |
0.076 |
220/60 |
0.043 |
M00DU GENERAL PURPOSE TYPE
M00DU-6~10 GENERAL PURPOSE TYPE(MANUAL OPERATION , TERMINAL BOX) |
|||
NOMINAL DIAMETER |
MOUNTING LENGTH |
H |
H : Non MANUAL OPERATION |
6 |
55 |
165 |
143 |
8 |
55 |
165 |
143 |
10 |
55 |
165 |
143 |
M00DU EXPLOSION-PROOF TYPE
M00DU-6~10 EXPLOSION-PROOF TYPE(MANUAL OPERATION) |
|||
NOMINAL DIAMETER |
MOUNTING LENGTH |
H |
H : Non MANUAL OPERATION |
6 |
55 |
186 |
164 |
8 |
55 |
186 |
164 |
10 |
55 |
186 |
164 |
M00DU DUST EXPLOSION-PROOF TYPE
M00DU-6~10 DUST EXPLOSION-PROOF TYPE |
|||
NOMINAL DIAMETER |
MOUNTING LENGTH |
H |
H : Non MANUAL OPERATION |
6 |
55 |
231 |
209 |
8 |
55 |
231 |
209 |
10 |
55 |
231 |
209 |
6. Kaneko 3-way solenoid valve-M50 SERIES
Feature
Packed type
Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid.
Safe explosion-proof construction
Explosion-proof type valves certified by the Ministry of Labor.
Highly durable
A mechanical life of five million operations or more is expectable.
Manual check is possible
Manual operation is possible. This mode can be used for operation check or switching in case of emergency.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20 – 60 deg.C
AMBIENT TEMPERATURE
-20 – 60 deg.C
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE
0 ~ 0.99MPa
Cv. FLOW FACTOR
0.18
ELECTRICAL SPECIFICATIONS
See below
STANDARD VOLTAGE
AC |
DC |
|||
V/Hz |
INRUSH A |
HOLDING A |
V |
A |
100/50 |
2.8 |
0.50 |
24 |
0.91 |
100/60 |
3.1 |
0.56 |
48 |
0.53 |
110/60 |
2.6 |
0.46 |
100 |
0.24 |
200/50 |
1.4 |
0.25 |
110 |
0.26 |
200/60 |
1.6 |
0.28 |
125 |
0.20 |
220/60 |
1.3 |
0.23 |
Product images
M50 AC GENERAL PURPOSE TYPE
M50 – 8–10 AC GENERAL PURPOSE TYPE |
|
NOMINAL DIAMETER |
H |
8 |
148 |
10 |
148 |
M50 DC GENERAL PURPOSE TYPE
M50 – 8–10 DC GENERAL PURPOSE TYPE |
||
NOMINAL DIAMETER |
H |
|
8 |
172 |
|
10 |
172 |
M50 AC EXPLOSION-PROOF TYPE
M50 – 8–10 AC EXPLOSION-PROOF TYPE |
||
NOMINAL DIAMETER |
H |
|
8 |
182 |
|
10 |
182 |
M50 DC EXPLOSION-PROOF TYPE
M50 – 8–10 DC EXPLOSION-PROOF TYPE |
||
NOMINAL DIAMETER |
H |
|
8 |
186 |
|
10 |
186 |
在线联系供应商
Other supplier products
Apollo act Apollo actuator Models A0025-A4000 uator Models A0025-A4000 | Apollo AE series electric actuatorApollo CS&CL Series electric actuatorAPollo G series actuatorApollo LB Series electric actuatorsApollo Rack a... | |
Kaneko manual reset solenoid valve -M55 SERIES | Feature A kind of safety valve capable of preventing malfunctioning. Being a semi-automatic type, the... | |
Norgren Proportional pressure control valve | 8240600.913602400, 8240400.91369713535.2050.000.00TYPE S6DH0019G03900150V1) SXE9573-A75-00/***2) V61B513A-A213JNorgren solenoid Flow control valv... | |
Rotex solenoid valve 2 PORT DIRECT ACTING NORMALLY CLOSED SOLENOID VALVE | Rotex solenoid valve 2 PORT AIR OPERATED ISOLATED PISTON NORMALLY CLOSED/ OPEN VALVERotex solenoid valve 2 PORT AIR OPERATED VALVERotex solenoid va... | |
Kaneko 2-way solenoid valve - M30 series | Feature Pilot valve and main valve because it directly, you can use 0 or differential pressure. For... |
Same products
VARIABLE AIR VOLUME (VAV) PRESSURE TRANSMITTER | 卖方: Alpha Instruments Inc. | Variable air volume (VAV) systems are an effective solution for reducing both the first cost and ... | |
Linear Hall Sensor AH3505 | 卖方: Nanjing AH Electronic Science & Technology Co., Ltd. | Linear Hall Sensor AH3505 Hall Sensor Hall Switch Features Rated working voltage 4.5 V ~ 6.5 V; O... | |
Unipolar Hall Sensor AH441 | 卖方: Nanjing AH Electronic Science & Technology Co., Ltd. | Featuresof our Rated working voltage 4.5 V ~ 24 V, the limit voltages as low as 3.5 V; Operatin... | |
Unipolar Hall Sensor AH443 | 卖方: Nanjing AH Electronic Science & Technology Co., Ltd. | Featuresof our Rated working voltage 4.5 V ~ 24 V, the limit voltages as low as 3.5 V; Operatin... | |
Unipolar Hall Sensor AH543 | 卖方: Nanjing AH Electronic Science & Technology Co., Ltd. | Featuresabout our Rated working voltage 4.5 V ~ 24 V, the limit voltages as low as 3.5 V; Opera... |