Home Automation Alarm System
Smart Home Operating Instructions一.Gateway The product was linked sensing system as the "hub" controller, plays various types of signals collected by the front end of each type of sensor, will be converted into WIFI signal RF transmitted to the platform with the server. Without this product, in front of the sensor can not complete its function.Radio signal processing front-end device (PIR, Door switch, Gas detector, Smoke detector, etc.) sent a distinction between processed and transmitted to the platform with the server via the mobile APP pushed to the user-related information, prompts the user to make the appropriate treatment. A variety of modes can customize zones and equipment, increased user freedom.Parameter:1, Voltage: 110V ~ 240V AC 50 / 60Hz2, Temperature range: -10 ~ + 55 ℃3, Current: ≤200mA4, Wifi working standards: 2.4G Hz 802.11b / g / n5, RF frequency: 433M Hz6, Receiver sensitivity: -110dB二.Wireless PIR1. Pull out the battery insulating sheet, probe into the 1 minute warm-up state, the indicator flashes 1 second interval, waiting sensors stable.2, The preheating is finished, the detector 5 minutes before entering the test mode, 5 minutes into the usage patterns.Test mode: When the detector detect the infrared signal, It will alarm;Use mode: The detector to detect infrared signals every 5 minutes, before the next probe, to achieve energy saving effect;3, The detector detects infrared signals, lights flash once, to send an alarm signal alarm box, but pushed to your APP, it informs the user;4, Key functions: Testing. Single press the probe into the five minutes’ testing mode so that users install, test.5, Anti-pet function: Pets in front of the infrared detector movement does not trigger an alarm, to avoid false alarms caused by pets;6, Low voltage remind function: When the battery is about to run out of the detector, the detector will send a low-pressure alarm signal to the alarm box, to remind the user to replace the battery;7, Inspection function: the detector can inform the user is online;8, The tamper function: when the detector is removed or opened, it will send a tamper alarm signal that prompts the user;Parameter:1, Voltage: DC3V (1 pcs CR123A battery), 2 years Battery2, Temperature range: -10 ~ + 55 ℃3,Alarm current ≤17mA Standby Current ≤15uA4, Wireless frequency: 433MHZ5, Box distance (open area) ≥100m6, Low pressure tips range: 2.5 ± 0.2V7, Detection angle: 110 °8, Detection range: 12m9, Anti-pet: ≤25kg10, Warning lights: red bright LED11, Anti-white light:> 6500LUX三.Wireless Door switch1, Door containing the host and auxiliary machinery, are mounted on the door and door frame (window similar), both part of the installation interval should be less than 10mm, when the spacing is more than 15mm, the transmitter can lights can be.2. Pull out the battery insulating sheet detector that is working properly. When the host and auxiliary engine separated, the indicator flashes once, to send an alarm signal alarm box; master and slave unit is closed, the light blinks once, and door sensor sends a resume signal.3, Low-voltage remind function: When the battery is about to run out of the detector, the detector will send a low-pressure alarm signal to the alarm box, to remind the user to replace the battery;4, Inspection function: to inform users detectors are online;5, The tamper function: when the detector is removed or opened, it will send a tamper alarm signal that prompts the user;Parameter:1, Voltage: DC3V (CR2450 button battery), 2 years battery life2, Temperature range: -10 ~ + 55 ℃3. Alarm current ≤17mA Standby Current ≤5uA4, Wireless frequency: 433MHZ5, Box distance (Open area) ≥100m6, Low pressure tips range: 2.5 ± 0.2V,7, Effective magnetic distance: ≥15mm四.Wireless remote controlFour buttons, Away, home arm, disarm and SOS emergency assistance;Parameter:1, Voltage: DC3V (CR2032 button battery), 2 years life2, Temperature range: -10 ~ + 55 ℃3,Alarm current ≤15mA Standby Current ≤2uA4, the radio center frequency: 433MHZ5, Box distance (Open area) ≥60m五.Wireless combustible gas detector1, Connected Power, detector self-test, the yellow light flashes once, the buzzer "drip" sound, the sensor enters warm-up state, the green indicator light flashes once per second; the green indicator light, indicating that the detector into the normal working condition.2, The detector is equipped with a key, key function: short press on the code, analog alarm; press reset detector.3, The detector detects combustible gas leak after the red light is blinking, while buzzer "bit" alarm sound, alarm box to send an alarm signal, after the exclusion of the combustible gas detector automatically returns to the monitor state, and sends an alarm recovery signal alarm box.4, Yellow lights lit, the buzzer sounding, indicates that the sensor internal fault.5, The detector prolonged use, there will be some oil gas convection window attachment and gas sensitivity, it is recommended once every three months to clean up around the convection window.6, Lighting information:Red flashes Gas leak alarmGreen flashes Being activated internal sensorGreen alway lights Normal workingYellow alway lights An internal faultParameter:1, Detection of gas: natural gas;2, Voltage: DC5V (5v external adapter)3, Standby current: ≤100mA Alarm current: ≤150mA4, Alarm concentration: 6% LEL (alarm concentration error: ± 3% LEL);5, The sound pressure range: ≥70dB (1m)6, network alarm: send alarm signals to the alarm box upon detection of combustible gases.7, local alarm: The local sound prompt, after exclusion of the combustible gas detector automatically restored upon detection of combustible gases;8, the detector can be set to 24-hour zones, when that is disarming, still work;9, sensor fault detection function: sensor failure will alert the user to replace or repair;10, Self-test report: can inform the user whether the detector is working properly;11, The detector is equipped with a key, key functions: Testing, Local analog alarm;12, Wireless frequency: 433M13, Wireless distance: with the alarm box is more than 100 meters.六.Wireless smoke alarmParameter:1, Voltage: DC 3V (battery-powered)2, Standby current: <5uA3, Alarm current: <40mA4, Temperature: -10 ℃ ~ + 50 ℃5, Humidity: ≤95% RH6, Wireless frequency: 433M7, Low battery alarm threshold: 2.5V ± 0.1V8, Design Standard: GB 20517-2006, EN 146049, Network alarm: send alarm signals to the alarm box upon detection of smoke.10,Local alarm: ≥85dB (3m) When detects the smoke ,it will sounder,after smoke exclude, detector automatic recovery;11, The detector can be set to 24-hour zones, when that is disarming, still work;12, A self-test report: can inform the user whether the detector is working properly;13, The detector is equipped with a key, key functions: Testing, Local analog alarm;
Other supplier products
|
|
ANKA Sci-Tech Co.,Limited is one of the leading China siren aj-es86r manufacturers and suppliers, and also a professional company equipped with pro... |
|
|
ANKA Sci-Tech Co.,Limited is one of the leading China burglar security alarm system, home security alarm system, burglar security alarm system, wir... |
|
|
ANKA Sci-Tech Co.,Limited is one of the leading China siren aj-fb01 manufacturers and suppliers, and also a professional company equipped with prod... |
|
|
ANKA Sci-Tech Co.,Limited is one of the leading China independent smoke detector aj-703d/aj-703r manufacturers and suppliers, and also a profession... |
|
|
ANKA Sci-Tech Co.,Limited is one of the leading China gsm and pstn wireless home security aj-380 manufacturers and suppliers, and also a profession... |
供应产品
Same products