SF6 reference Capacitor - 400kV 50pF compressed gas standard capacitor
Genneal Information:
Compressed air standard capacitor is a necessary instrument in every HV test lab. It is used to measure the capacitance of capacitor, cable, sleeve, insulator, transformer winding, and insulating material, as well as tanδ of dielectric loss. At the same time, it can also be used as HV capacitor for pressure sharing device of HV measuring capacitor. Under certain condition, it can be used as HV coupling capacitor during partial discharge measurement.
Performance
Standard capacitor is used as comparison reference, which is assorted to precise measurement to inductance value, loss, capacitance, and dielectric loss value of HV equipment such as reactor,cable, transformer, sleeve, and capacitors etc. The standard capacitor is equipped with HV pole which can be connected with other HV parts in HV measuring circuit without partial discharge.
Standard capacitor is designed for indoor application, movable.
For extra high voltage, discrete capacitor grading is used to realize linear distribution of electric field,
so as to maintain an ambient humidity above 95% (without condensate water). Standard capacitor
has high voltage endurance and extremely stable humidity and voltage factor.
Specification :
- 50 pF capacity, 400 kV nominal tension, SF6 insulated, electrodes to avoid corona that meets thefollowing specifications.
- Tangent delta: <10-5
- Changes in capacity between 0% and 100% voltage: <5*10-5
- Stability in time: 0.01% / year.
- Temperature variation: 3 X 10 -5 K-1
- Pressure variation: <1% / year
- Frequency variation between 50 Hz and 1 kHz: <10-5
- Partial discharge <5 pC
Tests
- Accuracy of the calibration at its rated operating range: Primary voltage: from 0% to 100% Vn.
- Testing frequency supported at industrial power frequency.
Structure:
Ø Insulation sleeve and steel sheet made bottom and cover for casing. Bottom and cover are
fastened on both sides of insulation sleeve with stainless bolts and rings;
Ø Shielding case of capacitor is made of stainless pipe;
Ø HV/LV poles of capacitor is coaxial pole;
Ø Capacitor is equipped with pressure gauge and vent valve.
Ø Capacitor is filled with SF6. Pressure is 450±50kPa at 20 ℃.
Ø Capacitor frame is installed with universal wheel.
Ø External shielding plug socket of capacitor is adaptable to all kinds of bridge plugs
home/abroad.
Application conditions:
- RH: <80%
- Ambient T: -5~+40℃
- Altitude: <1000 m
- Rated voltage 400kV
- Withstand voltage: 440kV
- Rated frequency: 50Hz
- Capacitance: 50pF
- Capacitance stability: 0.01%/%/year
- Capacitance value accuracy: <5*10-5
- SF6 working pressure: 450±50KPa
- Capacitor tanδ: <1X10-5
- Capacitance pressure factor absolute value: ≤2.2×10-3/0.1Mpa
- Capacitance voltage factor absolute value: ≤3×10-5
- Capacitance temperature factor absolute value: ≤3×10-5/℃
- Capacitor shall bear 2Xrated air pressure test/72h.
- Sealing: ≤1% leakage rate/y
- Electric safety protection: LV pole overpotential protection
- Gas standard capacitor installation dimension:
- Base plate: 1650mm*1650
- Height: 3600mm
- Weight: <980kg
Complete supply:
- Standard capacitor: 1set
- Exclusive grading ring: 1piece
- Exclusive measuring cable: 1piece
- Junction box: 1piece
- Factory inspection report: 1copy
- Certificate: 1copy
- Technical manual: 2copies
- 0.05% measurement bridge 1 set
在线联系供应商
Other supplier products
Mobile substation | Mobile substation Performance characteristics ① Rapid allocation: connections between equipments are connected .After connected to earth system and... | |
Partial Discharge Testing Detector Testing instrument | Partial Discharge Testing Detector Testing instrument RequestedService Condition: Ambient temperature:0~20℃±2℃ Relative humidity:≤80% Po... | |
Tansformer Insulation Testing Station design | Tansformer Insulation Testing Station design We will be willing to provide whole-process engineering consulting servicesfor you: Preparingfeasibili... | |
AC Series Resonant Test System | AC Series Resonant Test System Applications Resonant Test Systems is appliedfor the generation ofa continuously variable alternating (AC) voltage ... | |
Shielding hall of HV PD test | Shielding hall of HV PD test Application: HV test shielding room (faraday cage) areWidely used in power cable, transformer, transformer switch, tra... |
Same products
CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS | 卖方: ZK Electronic Technology Co., Limited | Part Number:CSD16301Q2 Description:CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS ... | |
CAPACITOR EEF-CX0J10CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF1R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF | 卖方: ZK Electronic Technology Co., Limited | Part name:EEF-CX0J101R Description:CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V ... | |
Heavy Copper PCB Manufacturer | 卖方: Xinfeng Huihe Circuits Co., Ltd. | Heavy Copper PCB, pcb fabrication up to 12oz, large current, pcb circuitfabrication base material... | |
8 Layer ENIG Half Hole Custom PCB | 卖方: Xinfeng Huihe Circuits Co., Ltd. | Number of layers: 8 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 4/3mil Inner lay... | |
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board | 卖方: Xinfeng Huihe Circuits Co., Ltd. | Number of layers: 4 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 6/4mil Inner lay... |