ERMS-2000-M Mobile Vehicle Exhaust Telemetry System
Overview
The ERMS2000-M movable vehicle emission testing machine, developed by our company, is suitable for mobile enforcement of city roads and stationary enforcement of single lane. It can detect the CO, CO2, NO, HC and opaque smoke intensity in gasoline and diesel vehicle exhaust through TDLAS, UV-DOAS, weak signal detection technology and image recognition technology with fast response time (<0.5s) as well as simple system operation. The measured signals are transmitted through WIFI, and it can be connected to LED screen to display vehicle exhaust emission information. Dispensing with sample extraction, the technology avoids the interference and uncertainty from sampling to reflect the pollution condition of vehicle exhaust emission objectively.
Feature Of ERMS-2000-M Mobile Vehicle Exhaust Telemetry System
Small size and handiness:
highly integrated design with small size and handiness, which is beneficial for movable operation;
Efficient site layout:
adopt a unique optical path adjustment module, able to complete site layout in a very short time;
Narrow-wave radar speed measurement:
adopt narrow-wave radar speed measurement with low microwave irradiation, low power consumption, long service life, high stability, and reliability; locate target accurately to avoid adjacent clutter interference; fast response time to ensure the capture rate and instantaneity of the target;
Integrated calibration system:
four components (CO, CO2, HC, NO) can be calibrated simultaneously, support both manual/auto calibration with simple operation and high efficiency;
Real-time data matching:
real-time data matching without post-processing; output monitoring results in real time; combined with vehicle identification technology, screen excessive emission vehicle;
Remote online monitoring system:
online monitor battery status, calibration state, system alarm information, wireless communication signals and etc. Remote monitoring and operation, convenient for the operator to
monitor system parameters;
Auto record and storage:
logs will record all the operating and alarm information for query and tracing, which is convenient for problem processing and solving. The outage will not affect data storage.
Application Of ERMS-2000-M Mobile Vehicle Exhaust Telemetry System
The product is used for the online monitoring of CO, CO2, NOx, HC, and opacity in vehicle exhaust emission. All parts are in the deft design and convenient for installation, which can be installed in all road sections and toll gates. It can form an online monitoring web through appropriate deployment in the typical area. Combined with network transmission technology, it can achieve data sharing and result display with environment detection center and vehicle management center, which provide a scientific basis for decision maker and vehicle exhaust pollution control measures, thus achieve the goal of online monitoring for the city vehicle pollution.
Specification Of ERMS-2000-M Mobile Vehicle Exhaust Telemetry System
Factors |
Range |
Absolute Error |
Relative Error |
WHAT |
0~10% |
±0.25% |
±10% |
CO2 |
0~16% |
±0.25% |
±10% |
HC |
0~10000ppm |
±10ppm |
±10% |
NO |
0~10000ppm |
±20ppm |
±10% |
Opacity |
0~100% |
±2% |
±5% |
Pollutant Repeatability: NO, HC, CO, and CO2 is a half of the maximum permissible error.
Speed Range: 10km/h~120km/h
When speed at 10km/h~50 km/h, error≤±1.5 km/h
When speed at 50km/h~120 km/h, error≤±3.0 km/h
Acceleration Error: ≤±0.2m/s2
Vehicle Image Capture Rate: ≥98%
Vehicle License Recognition Rate: ≥90%
Vehicle Image: picture will be saved in database in form of JPEG
Data Transmission Method: wireless wifi, wired broadband or 4G transmission
Response Time: ≤0.5s (T90) (system processing period)
Ambient Temperature: -40℃~+85℃, error≤±0.2℃
Relative Humidity: 0~100%RH, error≤±3%RH
Wind Seed: 0~60m/s, error≤±0.3m/s or ±3%, take the maximum
Atmospheric Pressure: 10hPa~1100hPa, error≤±5hPa
在线联系供应商
Other supplier products
EQMS VOCs Online Monitoring System | We have air quality monitors for sale! Volatile Organic Compounds (VOCS) are carbon based compounds that pose a significant health hazard due to th... | |
Continuous Emission Monitoring & Process Control | What is the continuous emission monitoring system working principle? The instruments and analyzers produced by Zetian now are widely used at home a... | |
DMS-100/MS-1000 Dust Monitor | HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in en... | |
WDet-5000UVI Immersion UV Water Analyzer | Overview Of WDet-5000UVI Immersion UV Water Analyzer WDet-5000UVI is the first full-spectrum (200-800nm) immersion UV portable water quality analy... | |
AM-5100 SO2 Analyzer | Overview AM-5100 SO2 analyzer adopts ultraviolet fluorescence technique and combines advanced micro processing technology, which could provide accu... |
Same products
The Burkina Faso- | 卖方: 河南天驰仪器设备有限公司 | In the field of biodiversity conservation and agricultural research, the proper preservation of p... | |
Ball Control Valve | 卖方: China Topper Control Valves Manufacturer Co., Ltd. | The Ball Control Valve manufactured by China Valve is a cutting-edge solution designed to precise... | |
Hand Folding Machine | 卖方: Anhui Blackma Heavy Industrial Machinery Co.,LTD | Hand Folding Machine This machine is able to bend the flange sheet metal to get three folds, and... | |
Electric Shearing Machine | 卖方: Anhui Blackma Heavy Industrial Machinery Co.,LTD | Electric Shearing Machine The machine is overall steel-welded and gate-type with chain drive. Th... | |
Electric Rolling Machine | 卖方: Anhui Blackma Heavy Industrial Machinery Co.,LTD | Electric Rolling Machine Pre-bending function makes straight edges narrower, and it can even rou... |