Zetian technology is the only high and new technology company with a full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultravio
Overview
Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing environment and safety monitoring instruments as well as the latest demand at home and abroad, our company has launched a new generation DPM-6000 atmospheric particulate monitor with high accuracy, reliability, stability and economy. It can measure PM10, PM2.5 and dust particles of other cut sizes, widely applied in inhalable particles concentration detection in environmental atmosphere monitoring.
Principle Of DPM-6000 PM MonitorPM2.5/PM10
The monitoring principle of the pm measuring deviceis mainly based on enrichment technology of atmospheric particulate and beta ray attenuation method. The instrument concentrates on particulate matters whose aerodynamic equivalent diameter is smaller than 2.5/10μm on the rolled filter membrane. The instrument adopts low-radiation 14C as a radioactive source. The emitted Beta-ray passes through the filter membrane with contaminants and will be received by the detector. The detector is composed of a photo-multiplier tube (or Geiger detector), plastic scintillator and counter. The thickness of enrichment can be analyzed quantificationally according to Beta-ray energy that detector received, then the PM2.5/10 concentration in the air can be calculated.
Features Of DPM-6000 PM Monitor PM2.5/PM10
The design of the gas path keeps filter paper, a radioactive source and detector immovable during enrichment and measurement, ensuring a good lower detection limit.
US EPA standard beta ray attenuation method, which spares the complicated operations of TEOM, such as manually replace filter paper and weight. Compared to the light scattering method, it has higher measurement accuracy.
Cutter, based on simulation verification of aerodynamics, will provide a various selection of accurate particle.
Sizes: PM1, PM2.5, PM10, TSP.
Sampling flow is measured by a mass flow sensor and corrected with collected ambient temperature and pressure to get the sampling flow of the field.
Use C14 source which is of low-density, low activity, and long half-life to realize stable measurement. No special protection is needed. Reliable and safe.
Flexible paper-pressing structure. Mechanical driving design is simple and reliable; greatly reduce paper breaking and paper jam and avoid the error caused by the moving of filter paper.
The pipeline heating system is used to eliminate interference from ambient humidity and make the detector fit into sudden.
Flow control system with precise closed-loop feedback; stable sampling flow and small error.
Various external ports, such as RS232/RS485, 4~20mA and etc.
Low maintenance frequency, once a year.
Specification Of DPM-6000 PM Monitor PM2.5/PM10
Measuring principle |
Beta ray attenuation method |
|
Performance Index |
Measuring Range |
0~1000μg/m3³or 0~10000μg/m3 (optional) |
Radioactive Source |
14C (carbon-14), radioactivity≤60μCi |
|
Accuracy |
≤5% |
|
Display Resolution |
1μg / m3 |
|
Lower Detection Limit |
5μg / m3 |
|
Flow Error |
≤±2% (generally set at 16.67L/min) |
|
Sampling Flow Stability |
≤±2% working point flow/24h |
|
Sampling Period |
≤1h (time is settable) |
|
Sampling Flow |
Default 16.67L/min |
|
Parallelism |
PM10≤10%,PM2.5≤15% |
|
Filter Paper Tape |
Filter Paper Tape |
Glass fibre, inner diameter:40mm,width: 30mm, service time 1 month (work period 1 h) |
Interface For. |
I / O |
Rs232, RS485, 4-20mA, GPRS (optional) |
Data Storage |
One year |
|
Working Condition |
Cuttingheader |
Ambient temperaure (-40~50)℃, ambient pressure (80~106)kPa |
Detector |
Ambient temperature (5-40)℃, ambient pressure (80-106)kPa, humidity (≤90%) |
|
Power Supply |
AC (220 ± 22) V, (50 ± 1) Hz |
|
Dimension & Weight |
483×407×322(mm)(L×W×H); Monitor 30kg, Pump 8kg |
Application Of DPM-6000 PM Monitor PM2.5/PM10
Inhalable particle real-time monitoring in industry,, construction, residential district and etc.
Environment assessment, permission, and pollution forecast and pre-warning.
Ambient air quality monitoring and mobile air monitoring experimental station.
Occupational disease research, and long-term background environment research.
Secondary emission monitoring (coal storage area, wharf, etc.).
Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testingproducts. We're internationally recognized. Welcome you to visit us.
在线联系供应商
Other supplier products
HM-200 Hygronom | Overview Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, the precision humidity ... | |
WDet-5000UVI Immersion UV Water Analyzer | HANGZHOU CHUNLAI (ZETIAN) TECHNOLOGY was established in 2008, and has national wide impact in China now as a fast-growing company specialized in en... | |
EQMS-3000B Environmental Quality Monitoring System | Overview According to the status and characteristics of construction sites and production industry generated pollution, applying more sophisticate... | |
Zetian technology is the only high and new technology company with a full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultravio | Overview Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing en... | |
WDet-5000 Total Phosphorus Online Automatic Analyzer | HANGZHOU ZETIAN TECHNOLOGY CO., LTDwas established in 2008, and has national wide impact in China now as a fast-growing company specialized in env... |
Same products
iX361 中框校正夹 | 卖方: 深圳维客修有限公司 | Fixes iCF6/iA3/iX16/iX361手机屏幕中框维修治具。iFixes iCF6免加热开屏器用于手机液晶拆解无需加热。iFixes iX361中框矫正维修平台。iFixes IA3... | |
单相电表测试仪 | 卖方: 782364 | GF112D是一种单相手持式电子电表测试装置,精度等级为0.05、0.1或0.2,用于现场测试单相电表误差。测量范围从1mA到120A, 0到600V,也可用于测试交流参数—&mda... | |
单相电表测试仪 | 卖方: 782364 | GF112D是一种单相手持式电子电表测试装置,精度等级为0.05、0.1或0.2,用于现场测试单相电表误差。测量范围从1mA到120A, 0到600V,也可用于测试交流参数—&mda... | |
单相电表测试仪 | 卖方: 782364 | GF112D是一种单相手持式电子电表测试装置,精度等级为0.05、0.1或0.2,用于现场测试单相电表误差。测量范围从1mA到120A, 0到600V,也可用于测试交流参数—&mda... | |
数字轨距 | 卖方: Wuhan linkage track equipment co.,ltd | 产品描述 数显轨头磨损仪主要用于测量钢轨的垂直磨损和横向磨损,设计合理,重量轻,操作方便,读数直观。 特征 1.数字直读式:LCD显示屏,清晰易读;无需计算,直接读数;读数时,按住... |