Safety Mat Safety Relay
Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.
The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).
Features & Advantages of Safety Mat Safety Relay
2-wire safety mats/edge
4-wire safety mats/edge
Automatic reset
Monitored manual reset
Parameter of Safety Mat Safety Relay
|
CZSR8301-3A1B |
CZSR8301-3A1B(M) |
CZSR8302-3A1B |
CZSR8303-3A1B |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC/AC |
100V~230V AC |
|
Voltage tolerance |
- |
|||
|
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤7 VA (220V AC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤10mA (24V DC) |
≤10mA (220V AC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
|
Input devices |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats, safety edges (2 or 4-wire) |
|
Number of contacts |
3NO+1NC |
3NO+1NC |
3NO+1NC |
|
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms |
≤30ms |
|
Recovery time |
≤300ms |
≤300ms |
≤100ms |
≤500ms |
|
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
|
Pollution degree |
2 |
2 |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
PLe |
PLe |
|
Category |
|
CZSR8302-2A1B1S |
CZSR8302-2AT1BT1S |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
|
Voltage tolerance |
||
|
Current consumption |
≤120mA (24V DC), ≤300mA (24V AC) |
≤120mA (24V DC), ≤300mA (24V AC) |
|
Input current |
≤10mA (24V DC) |
≤10mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
|
Input devices |
Safety mats, safety edges (2 or 4-wire) |
Safety switches, Contact switches |
|
Terminal resistance |
||
|
Number of contacts |
2NO+1NC+1SO |
2NO(t)+1NC(t) |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Semiconductor output data |
Number of semi-output:1SODriving ability:20mA/24V DC |
Number of semi-output:1SODriving ability:20mA/24V DC |
|
Switch-on delay |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms(instantaneous) |
≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s) |
|
Recovery time |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
|
Pollution degree |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
|
Category |
Block Diagram of Safety Mat Safety Relay
Typical Applications of Safety Mat Safety Relay
CHENZHUstrives to provide high-quality products and services to meet the expectations of our customers and interested parties by delivering outstanding performance. We have special talents to research and develop automation and safetysystem. Indeed, automation and safety are our interface products' main characters.
在线联系供应商
Other supplier products
| Light Curtain Safety Relay | Light Curtain Safety Relay Light curtain Safety Relaysupports PNP-type light beam devices. Safety relay modules provide a high level of fail-safe ... | |
| DO Signal (SIS) Input 24V DC 5A Safety Relay | DO SISSignalInput 24V DC 5A Safety Relay These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS,... | |
| Photovoltaic 1000 DC Power SPD | SPD for DC power, 1000v spd; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovoltai... | |
| A Brief Introduction of Intrinsically Safe Barrier | Intrinsically safety barriers in instrumentationimproves workplace safety by limiting the energy available in the process. Ⅰ. What is intrinsica... | |
| GS8500-EX Series Intrinsic Safety Barrier | GS8500-EX range functional safety isolated barriers are CHENZHU's hit products, which obtained the first IECEx, ATEX, DE TUV SIL, JP TIIS certifica... |
Same products
| Ring Blower (2RB310A11) Air Blower | 卖方: Greentech Industry (Jinan) Co., Ltd | Features:1. Beautiful surface2. Easy installation3. Low noise level4. No vibration, and therefore... | |
| Energy Saving High Pressure Low Noise Rotary Air Blower for Industrial/Aquaculture | 卖方: Greentech International (Zhangqiu) Co., Ltd | HC rotary air blower structure and working principleThe rotary blower has an exquisite structure ... | |
| Easy to Install Hc Rotary Air Blower for Laboratory Water Treat | 卖方: Greentech International (Zhangqiu) Co., Ltd | HC rotary air blower structure and working principleThe rotary blower has an exquisite structure ... | |
| Lt200A Roots Blower Positive Pressure Suitable for Industrial Heavy-Duty Applications | 卖方: Greentech International (Zhangqiu) Co., Ltd | Greentech International (Zhangqiu) Co., Ltd. is a leading manufacturer of blowers and vacuum pump... | |
| Greentech Lt-065 380V Low-Noise Three-Lobe Roots Blower | 卖方: Greentech International (Zhangqiu) Co., Ltd | Three lobes blowers are new series roots type blowers. By cnc machinewe made precise rotors to pr... |