DO Signal (SIS) Input 24V DC 5A Safety Relay
These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output.
The emergency stop safety relay can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.
Features & Advantages of DO Signal (SIS) Input 24V DC 5A Safety Relay
Several contacts output
Low start-up inrush current
Parameter of DO SIS SignalInput 24V DC 5A Safety Relay
CZSR8001-3A1B |
CZSR8001-2A2B |
|
Supply voltage |
24V DC |
24V DC |
Voltage tolerance |
||
Current consumption |
≤90mA (24V DC) |
≤90mA (24V DC) |
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
Cable resistance |
≤15Ω |
≤15Ω |
Input devices |
DO signals |
DO signals |
Number of contacts |
3NO+1NC |
2NO+2NC |
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms |
≤30ms |
Recovery time |
≤100ms |
≤100ms |
Supply short interruption |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
Overvoltage category |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
Category |
If you want buy a high quality dc power surge protector, please choose Chenzhu!
在线联系供应商
Other supplier products
Conceptual Difference Between Temperature Transmitter and Temperature Sensor | differential temperature transmitterand temperature sensor The temperature sensor is a general term for devices that can sense a prescribed me... | |
Signal SPD | Electronic devices are always threatened by power surges and transients caused by power failures or nearby lightning strikes. Signal SPDsurge pr... | |
Intrinsic Isolated Barrier | Intrinsic Isolated Barrier Intrinsically safe electrical equipmentand isolators use intrinsically safe explosion-proof and functional safety techn... | |
E-Stop Button, Safety Gate Safety Relay | CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 ... | |
DC Power SPD | dc power surge protector dc spd 1000v dc surge protector solar solar dc spd dc surge arrestor? surge arrester dc dc surge suppressor dc spd ... |
Same products
70-110kw Commercial Three Phase String Inverter | 卖方: Shanghai Sunplus New Energy Technology Co., Ltd | The Sunplus BNT Series are designed for commercial and power plant PV system applications, rating... | |
3-6kW String Inverter Single Phase | 卖方: Shanghai Sunplus New Energy Technology Co., Ltd | Ais a device commonly used in residential and small commercial photovoltaic (PV) solar systems. I... | |