SF6 Gas 11 KV Load Break Switch
The 11kv load break switchis suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency 50/60Hz, which can break off and close the load current and overload current in the power system. The 11 KV SF6 LBSis equipped with an intelligent controller to realize the automation of the distribution system. Inquiry 11kv load break switch price.
SF6 Gas 11 KV Load Break Switch Features
The operating mechanism with spring energy storage ensures fast closing and switching operation (<1000ms).
Operator place: Local/Remote.
11KV LBSequipped with an electronic controller, this sf6 load break switch can be operated locally or with FTU/RTU interface for console operation.
SF6 Gas 11 kv Load Break Switch In Pole Mounted Switch Solution
The type of high-voltage bypass type SF6 11KV LBS insulated load switch is divided into manual type and electric type, which is an engineering bypass type load switch used for the maintenance and construction of power distribution cabinet in order to make uninterrupted power supply to distribution lines. This 11kv load break switch utilizes SF6 gas, known for its outstanding insulation and arc extinguishing performance. Inquiry 11kv load break switch price. Check more pole top switches.
SF6 Gas 11KV Load Break Switch PDFSpecification
Parameter Name |
Unit |
Technical Requirement |
Rated Maximum Voltage |
kV |
12 |
Rated continuous Current |
A |
630 |
Short Time Withstand Current |
kA |
20 |
Short-circuit Making Current (peak) |
kA |
50 |
Power Operating Time (Close/Open) |
sec |
<2 |
Mechanical Operations |
times |
3000 |
Rated full load operations |
times |
400 |
Breaking Capacity |
||
Main Active (0.7pf) |
A |
630 |
Cable charging |
A |
5 |
Transformer magnetizing |
A |
10 |
Lightning Impulse Withstand Level |
||
Phase to Earth |
kV |
75 |
Across interrupter |
kV |
85 |
Power Frequency withstand voltage |
||
Phase to Earth |
kV |
42 |
Across interrupter |
kV |
50 |
Other Ratings & Specifications |
||
Creepage Distance (Silicon) |
mm |
830 |
IP Level |
65 |
|
Arc Extinction Medium |
SF6 Gas |
|
Insulation Medium |
SF6 Gas |
|
Leakage Rate |
cc/ sec |
≤0.5% |
Product size (max) |
||
Width |
mm/in |
1368/54 |
Height |
mm/in |
530/21 |
Environmental Conditions for Equipment Use of SF6 Gas 11KV Load Break Switch
Environmental conditions for equipment use |
height above sea level:≤3000m |
Air temperature: -40℃~+50℃ |
Maximum diurnal temperature difference:≤25℃ |
Relative humidity:Daily mean95% monthly average90% |
Maximum wind speed:≤34m/s |
Earthquake intensity:<8 degree |
Icing thickness: <10mm |
Thickness of snow: <35mm |
irradiance: <0.1W/cm2 |
Pollution grade: Ⅲ class, Ⅳ class Ⅲ, Ⅳ |
Installation site: No fire disaster, explosion danger, chemical corrosion, and frequent strenuous vibration places |
11 KV Load Break Switch Working Procedure
The 11KV LBS load switch that uses SF6 gas as insulation and arc extinguishing medium is called the SF6 gas load break switch. It can be used to switch and switch load current and overload current, and it can also be used to switch and switch no-load circuits, no-load transformers, and capacitors and outdoor pole mounted load break switch groups, among others. All three-position load switches with the functions of connecting, disconnecting, and grounding have the characteristics of simple structure and low price. But the load switch cannot disconnect the short-circuit current.
Intended Use of SF6 Gas 11KV Load Break Switch
The 11KV LBS SF6 load switch is an excellent load switch that many users have experienced in recent years. In addition to its long electrical life and strong braking force, it has the same advantages as the vacuum load switch. Its outstanding advantage is that it is easy to achieve three working positions (connected, disconnection and grounding), small current (inductance, capacitance) breaking, strong resistance to severe environmental conditions. It is suitable for popularization and application in urban and rural medium voltage distribution networks.
As a reliable electric power equipment company, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
33KV SF6 Gas Load Break Switch | These load break switch 33kvare intended for outdoor applications. They can be mounted either horizontally or vertically, and are suitable for elec... | |
11KV Vacuum Circuit Breaker | 11KV Vacuum Circuit Breaker ZW32 series 11kv vacuum circuit breaker are used in distribution systems. 11kv auto reclosersare used to make and brea... | |
SF6 Gas 11 KV Load Break Switch | SF6 Gas 11 KV Load Break Switch The 11kv load break switchis suitable for the distribution network with the highest voltage 11kV, the rated curren... | |
15KV SF6 Gas Load Break Switch | FWX1 LBS installed on the pole is suitable for rated voltage 12/24/40.5kV, rated current 630A, 50/60Hz Distribution network breaking. The load curr... | |