S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformerand GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended asthe major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
Product Features
- Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4%based on S9 series.
- Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air,so that extend the service life effectively.
- High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
- Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Model and Meaning
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss R(W) |
Load Loss R(W)75℃ |
Impedance Voltage (%) |
No-load Current(%) |
Length L(mm) |
Width W (mm) |
Height H(mm) |
Gauge Horizontal*Vertical(mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
(KV) High Voltage |
Tapping Range of High Voltage |
(KV)Low Voltage |
|||||||||||||
30 |
±5%±2×2.5% |
Dyn11Yzn11Yyn0 |
100 |
630/600 |
980 |
735 |
1145 |
400*400 |
178 |
78 |
355 |
||||
50 |
130 |
910/870 |
1017 |
758 |
1205 |
450*400 |
240 |
92 |
415 |
||||||
63 |
150 |
1090/1040 |
1035 |
785 |
1285 |
450*400 |
285 |
105 |
505 |
||||||
80 |
180 |
1310/1250 |
1065 |
800 |
1290 |
450*400 |
330 |
110 |
540 |
||||||
100 |
200 |
1580/1500 |
1072 |
820 |
1305 |
450*400 |
345 |
116 |
590 |
||||||
125 |
240 |
1890/1800 |
1155 |
1105 |
1310 |
450*550 |
415 |
135 |
705 |
||||||
160 |
280 |
2310/2200 |
1235 |
850 |
1535 |
550*550 |
485 |
155 |
835 |
||||||
200 |
340 |
2730/2600 |
1282 |
860 |
1557 |
550*550 |
582 |
168 |
965 |
||||||
250 |
400 |
3200/3050 |
1310 |
940 |
1605 |
550*550 |
695 |
210 |
1135 |
||||||
315 |
480 |
3830/3650 |
1465 |
1120 |
1915 |
660*650 |
855 |
255 |
1520 |
||||||
400 |
570 |
4520/4300 |
1440 |
1165 |
1725 |
660*660 |
950 |
295 |
1590 |
||||||
500 |
680 |
5410/5150 |
1510 |
1250 |
1845 |
660*650 |
1150 |
320 |
1905 |
||||||
630 |
810 |
6200 |
1650 |
1140 |
1920 |
660*650 |
1500 |
435 |
2015 |
||||||
800 |
980 |
7500 |
2125 |
1175 |
2315 |
820*820 |
1910 |
760 |
3510 |
||||||
1000 |
1150 |
10300 |
2150 |
1380 |
2570 |
820*820 |
2125 |
880 |
3850 |
||||||
1250 |
1360 |
12000 |
2355 |
1485 |
2570 |
820*820 |
2605 |
960 |
4610 |
||||||
1600 |
1640 |
14500 |
2385 |
1750 |
2630 |
820*820 |
3125 |
1150 |
5420 |
||||||
2000 |
1940 |
18300 |
1940 |
1400 |
1700 |
820*820 |
2420 |
780 |
4200 |
||||||
2500 |
2290 |
21200 |
2050 |
1480 |
1800 |
820*820 |
2560 |
880 |
4680 |
Notes:
Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W)75℃ |
No-load Current (%) |
Short-circuit Impedance(%) |
||
High Voltage (KV) |
Tapping ranges of High Voltage |
Low Voltage(KV) |
||||||
30 |
20 |
±5% ±2×2.5% |
Dyn11Yzn11Yyn0 |
100 |
690/660 |
|||
50 |
130 |
1010/960 |
||||||
63 |
150 |
1200/1150 |
||||||
80 |
180 |
1440/1370 |
||||||
100 |
200 |
1730/1650 |
||||||
125 |
240 |
2080/1980 |
||||||
160 |
290 |
2540/2420 |
||||||
200 |
340 |
3000/2860 |
||||||
250 |
400 |
3520/3350 |
||||||
315 |
480 |
4210/4010 |
||||||
400 |
570 |
4970/4730 |
||||||
500 |
680 |
5940/5660 |
||||||
630 |
810 |
6820 |
||||||
800 |
980 |
8250 |
||||||
1000 |
1150 |
11330 |
||||||
1250 |
1380 |
13200 |
||||||
1600 |
1660 |
15950 |
||||||
2000 |
1950 |
19140 |
||||||
2500 |
2340 |
22220 |
Notes:
Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer
Model |
Voltage Combination |
Connection Group Symbol |
No-load Loss (W)75℃ |
Load Loss R(W) |
Impedance Voltage (%) |
No-load Current(%) |
Length L(mm) |
Width W(mm) |
Height H(mm) |
Gauge Horizontal*Vertical (mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
High Voltage (kV) |
Tapping Range of High Voltage % |
Low Voltage (kV) |
|||||||||||||
50 |
±2×2.5%±5% |
Dyn11/ Yyn0 |
160 |
1200/1140 |
1195 |
935 |
1825 |
660*660 |
300 |
330 |
860 |
||||
100 |
230 |
2010/1910 |
1200 |
995 |
1935 |
660*660 |
470 |
383 |
1130 |
||||||
125 |
270 |
2370/2260 |
1235 |
940 |
1955 |
660*660 |
550 |
465 |
1335 |
||||||
160 |
280 |
2820/2680 |
1285 |
895 |
1950 |
660*660 |
580 |
485 |
1475 |
||||||
200 |
340 |
3320/3160 |
1310 |
1150 |
1985 |
660*660 |
680 |
595 |
1755 |
||||||
250 |
400 |
3950/3760 |
1450 |
1090 |
2010 |
660*660 |
860 |
650 |
2000 |
||||||
315 |
480 |
4750/4530 |
1930 |
1065 |
2320 |
820*820 |
980 |
765 |
2290 |
||||||
400 |
580 |
5740/5470 |
1850 |
1165 |
2015 |
820*820 |
1170 |
885 |
2725 |
||||||
500 |
680 |
6910/6580 |
2045 |
1205 |
2415 |
820*820 |
1340 |
960 |
3090 |
||||||
630 |
830 |
7860 |
2085 |
1240 |
2515 |
660*660 |
1550 |
895 |
3810 |
||||||
800 |
980 |
9400 |
2305 |
1615 |
2685 |
820*820 |
1990 |
1030 |
4510 |
||||||
1000 |
1150 |
11500 |
2545 |
1540 |
2590 |
1070*1070 |
2415 |
1475 |
5055 |
||||||
1250 |
1400 |
13900 |
2495 |
2010 |
2675 |
820*820 |
2480 |
1405 |
5290 |
||||||
1600 |
1690 |
16600 |
2680 |
2100 |
2770 |
820*820 |
2600 |
1490 |
5450 |
||||||
2000 |
1990 |
19700 |
2790 |
2180 |
2860 |
820*820 |
2720 |
1590 |
5600 |
||||||
2500 |
2360 |
23200 |
2900 |
2290 |
2980 |
1070*1070 |
2830 |
1720 |
5760 |
Notes:
S11 Series 35kV 630kVA-31500kVA Three-phase Dual Winding Power Transformer With Off Circuit Tap Changer
Model |
Voltage Combination |
Connection Group Symbol |
No-load Loss (W) |
Load Loss R(W) |
No-load Current(%) |
Short circuit impedance (%) |
Length L(mm) |
Width W(mm) |
Height H(mm) |
Gauge Horizontal*Vertical (mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
High Voltage (kV) |
Tapping Range of High Voltage % |
Low Voltage (kV) |
|||||||||||||
630 |
35 |
±2×2.5%±5% |
Yd11 |
830 |
7860 |
2400 |
1700 |
2210 |
820*820 |
2210 |
900 |
3250 |
|||
800 |
980 |
9400 |
2500 |
1850 |
2390 |
820*820 |
2350 |
1030 |
3500 |
||||||
1000 |
1150 |
1150 |
2700 |
1950 |
2510 |
820*820 |
2490 |
1180 |
3860 |
||||||
1250 |
1400 |
1390 |
2900 |
2050 |
2630 |
820*820 |
2600 |
1350 |
4350 |
||||||
1600 |
1690 |
1660 |
3050 |
2130 |
2750 |
820*820 |
2810 |
1580 |
4855 |
||||||
2000 |
2170 |
1830 |
3105 |
2195 |
2805 |
1070*1070 |
2800 |
1800 |
5300 |
||||||
2500 |
2560 |
1960 |
3150 |
2535 |
2980 |
1070*1070 |
3525 |
2060 |
7665 |
||||||
3150 |
35-38.5 |
±2×2.5%±5% |
3040 |
2300 |
3920 |
2725 |
2840 |
1070*1070 |
3995 |
2205 |
8565 |
||||
4000 |
3610 |
2730 |
3310 |
2915 |
3070 |
1070*1070 |
4825 |
2560 |
10115 |
||||||
5000 |
4320 |
3130 |
3480 |
3020 |
3145 |
1070*1070 |
5700 |
2635 |
11305 |
||||||
6300 |
5240 |
3500 |
3590 |
2905 |
3210 |
1475*1475 |
7120 |
3240 |
13510 |
||||||
8000 |
35-38.5 |
±2×2.5% |
YNd11 |
7200 |
3840 |
4070 |
3050 |
3595 |
1475*1475 |
8875 |
3840 |
16690 |
|||
10000 |
8700 |
4530 |
4106 |
2795 |
3655 |
2000*1475 |
10305 |
3600 |
17690 |
||||||
12500 |
1000 |
5380 |
4570 |
3010 |
3840 |
1475*1475 |
12830 |
4310 |
20990 |
||||||
16000 |
1210 |
6580 |
5235 |
3295 |
4615 |
2000*1475 |
16010 |
6650 |
27660 |
||||||
20000 |
1440 |
7950 |
5360 |
3415 |
4660 |
2000*1475 |
18820 |
7600 |
32170 |
||||||
25000 |
1700 |
9400 |
5830 |
3810 |
4860 |
2000*1475 |
22360 |
9800 |
42600 |
||||||
31500 |
2020 |
112000 |
6290 |
4290 |
5260 |
2000*1475 |
25110 |
12010 |
49960 |
Note: 1.For the transformer of low voltage 10.5kV, the connection group symbol is applicable to Dyn11.
Note: 2.For the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.
Note: 3.When the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
在线联系供应商
Other supplier products
Oil filled power transformer | Transformer is an important electrical equipment that must be used in our production and life. For transformer, it can control the voltage and cur... | |
high voltage step up transformer | distribution transformer The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Po... | |
non-encapsulated H-class dry-type power transformers | SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers... | |
GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears | GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears GGD series low voltage sw... | |
Why are some pebbles placed around the transformer? | Transformer is a kind of important equipment and type, such as thethree phase oil immersed transformer,which is constantly used in production and d... |
Same products
ACREL AID150 ALARM AND DISPLAY DEVICE | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |