high voltage step up transformer
distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformerand GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended asthe major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
Product Features
●Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4%based on S9 series.
● Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air,so that extend the service life effectively.
● High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
● Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss R(W) |
Load Loss R(W)75℃ |
Impedance Voltage (%) |
No-load Current(%) |
Length L(mm) |
Width W (mm) |
Height H(mm) |
Gauge Horizontal*Vertical(mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
(KV) High Voltage |
Tapping Range of High Voltage |
(KV)Low Voltage |
|||||||||||||
30 |
±5%±2×2.5% |
Dyn11Yzn11Yyn0 |
100 |
630/600 |
980 |
735 |
1145 |
400*400 |
178 |
78 |
355 |
||||
50 |
130 |
910/870 |
1017 |
758 |
1205 |
450*400 |
240 |
92 |
415 |
||||||
63 |
150 |
1090/1040 |
1035 |
785 |
1285 |
450*400 |
285 |
105 |
505 |
||||||
80 |
180 |
1310/1250 |
1065 |
800 |
1290 |
450*400 |
330 |
110 |
540 |
||||||
100 |
200 |
1580/1500 |
1072 |
820 |
1305 |
450*400 |
345 |
116 |
590 |
||||||
125 |
240 |
1890/1800 |
1155 |
1105 |
1310 |
450*550 |
415 |
135 |
705 |
||||||
160 |
280 |
2310/2200 |
1235 |
850 |
1535 |
550*550 |
485 |
155 |
835 |
||||||
200 |
340 |
2730/2600 |
1282 |
860 |
1557 |
550*550 |
582 |
168 |
965 |
||||||
250 |
400 |
3200/3050 |
1310 |
940 |
1605 |
550*550 |
695 |
210 |
1135 |
||||||
315 |
480 |
3830/3650 |
1465 |
1120 |
1915 |
660*650 |
855 |
255 |
1520 |
||||||
400 |
570 |
4520/4300 |
1440 |
1165 |
1725 |
660*660 |
950 |
295 |
1590 |
||||||
500 |
680 |
5410/5150 |
1510 |
1250 |
1845 |
660*650 |
1150 |
320 |
1905 |
||||||
630 |
810 |
6200 |
1650 |
1140 |
1920 |
660*650 |
1500 |
435 |
2015 |
||||||
800 |
980 |
7500 |
2125 |
1175 |
2315 |
820*820 |
1910 |
760 |
3510 |
||||||
1000 |
1150 |
10300 |
2150 |
1380 |
2570 |
820*820 |
2125 |
880 |
3850 |
||||||
1250 |
1360 |
12000 |
2355 |
1485 |
2570 |
820*820 |
2605 |
960 |
4610 |
||||||
1600 |
1640 |
14500 |
2385 |
1750 |
2630 |
820*820 |
3125 |
1150 |
5420 |
||||||
2000 |
1940 |
18300 |
1940 |
1400 |
1700 |
820*820 |
2420 |
780 |
4200 |
||||||
2500 |
2290 |
21200 |
2050 |
1480 |
1800 |
820*820 |
2560 |
880 |
4680 |
Notes:
在线联系供应商
Other supplier products
Distinguish Between Dry Type Transformer and Oil Immersed Transformer from The Outside | The biggest difference between anOil Immersed Transformerand aDry Type Transformeris that there is no "oil". Since the oil is liquid and has fluid... | |
Transformer Fault Reasons And Preventive Measures | Oill Transformer Manufacturertells us that operators should be familiar with the causes of transformer faults so that they can take timely treatm... | |
GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears | GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears GGD series low voltage sw... | |
three-phase transformer | The principle ofandis the same as that of ordinary transformer. All by electromagnetic induction. Isolation transformer generally refers to 380V/3... | |
Why are transformers mostly used in parallel? | Transformer in the process of running has run in parallel and series operation, but are used in most of the use of parallel operation, parallel o... |
Same products
ACREL AID150 ALARM AND DISPLAY DEVICE | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |