ENCAPSULATED ISOLATING PCB MOUNT POWER TRANSFORMER
Mainly used as power switching tool in single phase and three-phase electronic energy meter, or the other industrial instruments, measuring equipment or home appliance.It adopts vacuum epoxy sealed encapsulation, excellent waterproof, anti-seismic performance, and good insulating property. It can be dipped rinse by ultrasonic wave.It adopts high efficiency silicon steel sheet, special plug-in technics and low self-loss.Wide range of input voltage: 0.7UN-1.9UN, which can avoid misconnection or ground suppression fault etc. abnormal situations.Enclosure adopts flame resistant material, which meet the UL94V0 flame resistant design.It satisfies the relative requirement of IEC61036 Energy Meter Standard.DIMENSION & LABELMODEL DEFINITIONCOMMON MODEL SELECT TABLE (Un=220V)MODELINPUTOUTPUTRated voltageRated frequencyMax voltagePINPINVoltageCurrentPowerBPT2819E-2F0-115A220V50/60Hz1.5Un1-56-710V±0.5V30 mA1.15VA9-1010V±0.5V85 mABPT2819E-2F0-121A220V50/60Hz1.5Un1-56-711V±0.5V30 mA1.21VA9-1011V±0.5V80mABPT2819E-2F0-126A220V50/60Hz1.5Un1-56-712V±0.5V30 mA1.26VA9-1012V±0.5V75 mABPT2818E-2F0-105A220V50/60Hz1.9Un1-56-710V±0.5V25 mA1.05VA9-1010V±0.5V80 mABPT2818E-2F0-110A220V50/60Hz1.9Un1-56-711V±0.5V25 mA1.10VA9-1011V±0.5V75mABPT2819E-2F0-114A220V50/60Hz1.9Un1-56-712V±0.5V25 mA1.14VA9-1012V±0.5V70mABPT2819E-2F1-115A220V50/60Hz1.5Un1-56-710V±0.5V85 mA1.15VA9-1010V±0.5V30 mABPT2819E-2F1-121A220V50/60Hz1.5Un1-56-711V±0.5V80 mA1.21VA9-1011V±0.5V30mABPT2819E-2F1-126A220V50/60Hz1.5Un1-56-712V±0.5V75 mA1.26VA9-1012V±0.5V30 mABPT2819E-2F1-105A220V50/60Hz1.9Un1-56-710V±0.5V80mA1.05VA9-1010V±0.5V25 mABPT2819E-2F1-105B220V50/60Hz1.9Un1-56-711V±0.5V75 mA1.05VA9-1011V±0.5V20mABPT2819E-2F1-114A220V50/60Hz1.9Un1-56-712V±0.5V70 mA1.14VA9-1012V±0.5V25mANote: Under the terms of similar output frequency, output voltage and output current can be designed for clients. PLS confirm the exact model or offering relative parameters according to above table.OTHER PARAMETERSModelIsolated withstand voltageInsulation resistanceWorking temperatureStock temperatureBPT2819x-2F0-xxxxN1-N2, N3-N2 withstand voltage is 4000 Vrms,N1-N2 withstand 1000Vrms≥1000MΩ (test voltage: 500VDC)-50~+80℃-55~+85℃BPT2819x-2F1-xxxxN1-N3, N2-N3 withstand voltage is 4000 Vrms, N1-N3withstand is 1000Vrms≥1000MΩ (test voltage: 500VDC)-50~+80℃-55~+85℃Parameter instruction:Max input voltage: Under 25℃situation, full load, input 1.5Un or 1.9Un on the Pin1-5, the transformer will not be broken if power on for 4 hours.Isolated withstandvoltage: The power transformer that applied within the different windings, duration is 60 seconds, leakage current 1mA, no breakdown, no arcing.PAKINGDATANet /pcspcs/CTNWeight/CTNCubage/CTN
Other supplier products
|
|
Mainly used in single phase or three phase electronic energy meter, serving as current sampling tool or the current measuring tool for general indu... |
|
|
SPECIFICATON This product can be used as LED emergency light power supplyInstalled in the LED ceiling light.External power supply indicate,Website:... |
|
|
SPECIFICATION:Used for AC single phase active energy measuring. DIN rail installation type, compact design. Display type: LCD, unit is kwh, record ... |
|
|
Mainly used as power switching tool in single phase and three-phase electronic energy meter, or the other industrial instruments, measuring equipme... |
|
|
Mainly used in single phase or three phase electronic energy meter, serving as current sampling tool or the current measuring tool for general indu... |
供应产品
Same products