(FA-)SPYC, SPYCB (FA-)SPYCY, SPYCBY

0.6/1KV (FA-)SPYC,Website:, SPYCB (FA-)SPYCY, SPYCBYStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorSTinned annealed stranded copper, class 2 according to IEC 60228InsulationP85°C EPR as per JIS C 3401BeddingYPVC as per JIS C 3401ArmorC (CB)Galvanized steel wire braid(-C TYPE) or copper alloy wire braid(-CB TYPE)SheathYPVC as per JIS C 3401Outer sheath colorBlackCable ParameterConductorThick. of insulationThick. of beddingDia. over beddingDia. of armor(FA-) SPYC, SPYCBSizeConstructionO.DNominal overall dia.ToleranceCable weight (Approx.)mm2No./mmmmmmmmmmmmmmmmKg / Km1.57/0.531.591.01.05.90.37.20.41002.57/0.672.011.01.06.30.37.80.412047/0.852.551.01.06.90.38.20.414067/1.043.121.01.07.40.38.70.4170107/1.354.051.01.18.60.39.90.4225167/1.705.11.01.19.60.310.90.4300257/2.146.421.21.211.50.312.80.5425357/2.527.561.21.212.70.314.00.65355019/1.788.91.41.314.60.315.90.66957019/2.1410.71.61.417.20.318.50.79609519/2.5212.61.61.519.30.320.60.8125012037/2.0314.21.61.520.90.322.20.9151015037/2.2515.81.81.623.10.324.41.0183018537/2.5217.62.01.725.50.326.81.1225024061/2.2520.32.21.828.80.330.11.2291030061/2.5222..72.41.931.80.433.61.33680(FA-)SPYCY, SPYCBYConductorThick. of insulationThick. of beddingDia. over beddingDia. of armor(FA-) SPYCY, SPYCBYSizeConstructionO.DThick.of SheathNominal overall dia.ToleranceCable weight (Approx.)mm2No./mmmmmmmmmmmmmmmmmmKg / Km1.57/0.531.591.01.05.90.30.89.00.41352.57/0.672.011.01.06.30.30.89.40.415047/0.852.551.01.06.90.30.810.00.417567/1.043.121.01.07.40.30.810.50.4205107/1.354.051.01.18.60.30.811.70.5270167/1.705.11.01.19.60.30.912.90.5350257/2.146.421.21.211.50.30.914.80.6485357/2.527.561.21.212.70.31.016.20.66055019/1.788.91.41.314.60.31.018.10.77757019/2.1410.71.61.417.20.31.120.90.810609519/2.5212.61.61.519.30.31.123.00.9136012037/2.0314.21.61.520.90.31.224.81.0165015037/2.2515.81.81.623.10.31.227.01.1198018537/2.5217.62.01.725.50.31.329.61.2242024061/2.2520.32.21.828.80.31.433.11.3311030061/2.5222..72.41.931.80.41.436.61.53910
Other supplier products
|
|
|
Harmonized Code Industrial Cables H05V3V3H6-F/ H05V3V3D3H6-FApplication and DescriptionThis kind of flat cables are used in crews of elevators for ... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8102ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
225V SR Insulated & LSZH Sheathed Fire Alarm CablesJE-H(St)H…Bd FE180 E30 (CU/SR/OS/LSZH 225V Class 1)JE-H(St)HSWAH…Bd FE180 E30 (CU/SR/OS/LSZH/SWA... |
|
|
|
German Standard Industrial Cables Li2YCY/ Li2YCYv TPApplication and DescriptionThe PE-insulated data cable is designed for computer application and... |
|
|
|
German Standard Industrial Cables Li2YCY PiMFApplication and DescriptionLi2YCY PiMF is particularly suitable for wiring data systems and controls i... |