NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813

NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large material handling machines,Website:, e.g. excavators in open-cast mines subject to extremely high mechanical stresses. Particularly suitable for applications in which abrasion and chaffing stresses are to be expected in trailing operation.StandardsVDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationRubber type 3GI3.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in theouter interstices or Individual concentric distributed over core insulating coverings (coding…../3E).Reinforcing TapeExtremely tear-resistant reinforcing tape.InnerSheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant.Outer SheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant, inseparably bonded with inner sheath.Dimensions and Weight1.8/3kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/338.541.524703×35+3×25/342.945.930803×50+3×25/346.149.137503×70+3×35/349.753.746903×95+3×50/357.461.462103×120+3×70/361.265.274303×150+3×70/366.770.789003×185+3×95/370.674.6103303×25+2×25/2+1×10ST40.344.324703×35+2×25/2+1×10ST42.946.930803×50+2×25/2+1×10ST46.850.837503×70+2×35/2+1×10ST51.555.546903×95+2×50/2+1×10ST57.462.462103×120+2×70/2+1×10ST63.668.674303×150+2×70/2+1×10ST67.272.289003×185+2×95/2+1×10ST70.275.2103303.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/344.647.630803×35+3×25/347.650.635903×50+3×25/352.456.445203×70+3×35/356.360.355203×95+3×50/359.963.965803×120+3×70/365.669.681103×150+3×70/369.373.393203×185+3×95/373.277.2107803×25+2×25/2+1×10ST454932003×35+2×25/2+1×10ST47.651.636803×50+2×25/2+1×10ST535746403×70+2×35/2+1×10ST56.260.255503×95+2×50/2+1×10ST61.866.866503×120+2×70/2+1×10ST66.171.181603×150+2×70/2+1×10ST69.874.893403×185+2×95/2+1×10ST74.679.6108906/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/346.449.432703×35+3×25/349.153.138003×50+3×25/354.158.147503×70+3×35/3586257503×95+3×50/361.765.768303×120+3×70/367.471.483803×150+3×70/3717596203×185+3×95/376.780.7114303×25+2×25/2+1×10ST46.850.834103×35+2×25/2+1×10ST50.954.938903×50+2×25/2+1×10ST54.558.948603×70+2×35/2+1×10ST586257803×95+2×50/2+1×10ST63.568.569203×120+2×70/2+1×10ST67.872.884503×150+2×70/2+1×10ST71.576.596203×185+2×95/2+1×10ST76.381.3109808.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/352.656.640403×35+3×25/355.659.646303×50+3×25/358.962.953703×70+3×35/364.568.567203×95+3×50/368.272.278503×120+3×70/372.176.191303×150+3×70/377.681.6107503×185+3×95/381.585.5122903×25+2×25/2+1×10ST535741303×35+2×25/2+1×10ST55.659.647403×50+2×25/2+1×10ST59.363.354703×70+2×35/2+1×10ST64.668.668203×95+2×50/2+1×10ST68.373.379503×120+2×70/2+1×10ST74.479.492403×150+2×70/2+1×10ST78.183.1108603×185+2×95/2+1×10ST81.186.11240012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/356.960.946203×35+3×25/359.963.952203×50+3×25/3656963003×70+3×35/368.972.974103×95+3×50/372.576.585603×120+3×70/378.282.2102603×150+3×70/381.985.9115703×185+3×95/387.492.4135303×25+2×25/2+1×10ST57.361.347703×35+2×25/2+1×10ST59.963.953403×50+2×25/2+1×10ST65.469.464603×70+2×35/2+1×10ST68.872.874503×95+2×50/2+1×10ST74.479.486803×120+2×70/2+1×10ST78.783.7103703×150+2×70/2+1×10ST82.287.2116503×185+2×95/2+1×10ST/25kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×10ST64.768.759403×35+2×25/2+1×10ST67.371.364703×50+2×25/2+1×10ST717573003×70+2×35/2+1×10ST75.280.288003×95+2×50/2+1×10ST8085100503×120+2×70/2+1×10ST85.990.9114703×150+2×70/2+1×10ST89.694.6132103×185+2×95/2+1×10ST92.697.61486018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/369.573.566803×35+3×25/372.576.573803×50+3×25/377.681.684603×70+3×35/381.585.596903×95+3×50/384.989.9109603×120+3×70/390.695.6128303×150+3×70/394.399.3142503×185+3×95/×25+2×25/2+1×10ST69.973.971003×35+2×25/2+1×10ST72.676.675403×50+2×25/2+1×10ST788286803×70+2×35/2+1×10ST80.485.497603×95+2×50/2+1×10ST86.891.8111003×120+2×70/2+1×10ST91.196.1129803×150+2×70/2+1×10ST94.899.8143503×185+2×95/2+1×10ST99.6104.615870
Other supplier products
|
|
|
3.6/6KV,Website:, 6/10KV, 8.7/15KV, (FA-)SPYC, SPYCB, TPYC (FA-)SPYCY, SPYCBY, TPYCYStandards:JISC 3410-1999
IEC 60092-350
IEC 60092-35... |
|
|
|
XLPE Insulated,Website:, LSZH sheathed, CWB screened Instrumentation cables (Multipair)RE-2X(c)H 90°c / 300VSTANDARDSBasic design to EN 50288-7APPL... |
|
|
|
75Ω RG6 Armoured Coaxial Cable NEK606Applications :These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marin... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (2 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (3 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application... |
供应产品
Same products