NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813

NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large material handling machines,Website:, e.g. excavators in open-cast mines subject to extremely high mechanical stresses. Particularly suitable for applications in which abrasion and chaffing stresses are to be expected in trailing operation.StandardsVDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationRubber type 3GI3.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in theouter interstices or Individual concentric distributed over core insulating coverings (coding…../3E).Reinforcing TapeExtremely tear-resistant reinforcing tape.InnerSheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant.Outer SheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant, inseparably bonded with inner sheath.Dimensions and Weight1.8/3kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/338.541.524703×35+3×25/342.945.930803×50+3×25/346.149.137503×70+3×35/349.753.746903×95+3×50/357.461.462103×120+3×70/361.265.274303×150+3×70/366.770.789003×185+3×95/370.674.6103303×25+2×25/2+1×10ST40.344.324703×35+2×25/2+1×10ST42.946.930803×50+2×25/2+1×10ST46.850.837503×70+2×35/2+1×10ST51.555.546903×95+2×50/2+1×10ST57.462.462103×120+2×70/2+1×10ST63.668.674303×150+2×70/2+1×10ST67.272.289003×185+2×95/2+1×10ST70.275.2103303.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/344.647.630803×35+3×25/347.650.635903×50+3×25/352.456.445203×70+3×35/356.360.355203×95+3×50/359.963.965803×120+3×70/365.669.681103×150+3×70/369.373.393203×185+3×95/373.277.2107803×25+2×25/2+1×10ST454932003×35+2×25/2+1×10ST47.651.636803×50+2×25/2+1×10ST535746403×70+2×35/2+1×10ST56.260.255503×95+2×50/2+1×10ST61.866.866503×120+2×70/2+1×10ST66.171.181603×150+2×70/2+1×10ST69.874.893403×185+2×95/2+1×10ST74.679.6108906/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/346.449.432703×35+3×25/349.153.138003×50+3×25/354.158.147503×70+3×35/3586257503×95+3×50/361.765.768303×120+3×70/367.471.483803×150+3×70/3717596203×185+3×95/376.780.7114303×25+2×25/2+1×10ST46.850.834103×35+2×25/2+1×10ST50.954.938903×50+2×25/2+1×10ST54.558.948603×70+2×35/2+1×10ST586257803×95+2×50/2+1×10ST63.568.569203×120+2×70/2+1×10ST67.872.884503×150+2×70/2+1×10ST71.576.596203×185+2×95/2+1×10ST76.381.3109808.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/352.656.640403×35+3×25/355.659.646303×50+3×25/358.962.953703×70+3×35/364.568.567203×95+3×50/368.272.278503×120+3×70/372.176.191303×150+3×70/377.681.6107503×185+3×95/381.585.5122903×25+2×25/2+1×10ST535741303×35+2×25/2+1×10ST55.659.647403×50+2×25/2+1×10ST59.363.354703×70+2×35/2+1×10ST64.668.668203×95+2×50/2+1×10ST68.373.379503×120+2×70/2+1×10ST74.479.492403×150+2×70/2+1×10ST78.183.1108603×185+2×95/2+1×10ST81.186.11240012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/356.960.946203×35+3×25/359.963.952203×50+3×25/3656963003×70+3×35/368.972.974103×95+3×50/372.576.585603×120+3×70/378.282.2102603×150+3×70/381.985.9115703×185+3×95/387.492.4135303×25+2×25/2+1×10ST57.361.347703×35+2×25/2+1×10ST59.963.953403×50+2×25/2+1×10ST65.469.464603×70+2×35/2+1×10ST68.872.874503×95+2×50/2+1×10ST74.479.486803×120+2×70/2+1×10ST78.783.7103703×150+2×70/2+1×10ST82.287.2116503×185+2×95/2+1×10ST/25kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×10ST64.768.759403×35+2×25/2+1×10ST67.371.364703×50+2×25/2+1×10ST717573003×70+2×35/2+1×10ST75.280.288003×95+2×50/2+1×10ST8085100503×120+2×70/2+1×10ST85.990.9114703×150+2×70/2+1×10ST89.694.6132103×185+2×95/2+1×10ST92.697.61486018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/369.573.566803×35+3×25/372.576.573803×50+3×25/377.681.684603×70+3×35/381.585.596903×95+3×50/384.989.9109603×120+3×70/390.695.6128303×150+3×70/394.399.3142503×185+3×95/×25+2×25/2+1×10ST69.973.971003×35+2×25/2+1×10ST72.676.675403×50+2×25/2+1×10ST788286803×70+2×35/2+1×10ST80.485.497603×95+2×50/2+1×10ST86.891.8111003×120+2×70/2+1×10ST91.196.1129803×150+2×70/2+1×10ST94.899.8143503×185+2×95/2+1×10ST99.6104.615870
Other supplier products
|
|
|
S12 RU(c) 250 V EPR insulation,Website:, SHF2 sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke ... |
|
|
|
UL Industrial Cables HALAR/HMWPE Cathodic Protection Power CableApplicationThese cables are designed for use in cathodic protection deep well insta... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables... |
|
|
|
Type 210 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used for hand-held boring machines and drills.StandardsAS/NZS 1802:2003AS/NZS ... |
|
|
|
S9 IYXI(c) 60 V Collective Shielding Tele Cable NEK606Applications :These cables are flame retardant,Website:, low smoke and halogen free, used for... |