3.6 6kV 6 10kV 8.7 15kV IEC60092 MV Cable

3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (Halogen Free Inner Covering)ApplicationThese armoured MV cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke& halogen free.StandardsIEC 60092-350/351/354/359IEC 60332-1IEC 60332-3-22IEC 60754-1/2IEC 61034ConstructionConductorsClass 2 stranded copper conductor.Conductor ScreenSemi-conducting layer (tape/compound).InsulationXLPE.Insulation ScreenSemi-conducting layer (tape/compound).Metallic ScreenCopper tapeInner CoveringHalogen free compound.ArmourCopper wire braid.Outer SheathLSOH (SHF1). SHF2 can be offered upon request.Core IdentificationColoured tape shall be inserted under metallic screen.3core: Red, Yellow, Blue.Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 12×OD (single core); 9×OD (three core) Temperature Range: -30℃ ~ +80℃Dimensions and Weight3.6/6kVPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/km3.6/6KV-1C101×102.51.519.65803.6/6KV--1C161×162.51.520.56703.6/6KV-1C251×252.51.521.88003.6/6KV-1C351×352.51.623.29403.6/6KV-1C501×502.51.624.511003.6/6KV-1C701×702.51.726.513803.6/6KV-1C951×952.51.828.617003.6/6KV-1C1201×1202.51.930.420003.6/6KV-1C1501×1502.51.932.023203.6/6KV-1C1851×1852.52.034.427703.6/6KV-1C2401×2402.62.138.035303.6/6KV-1C3001×3002.82.341.242703.6/6KV-1C4001×4003.02.445.654103.6/6KV-1C5001×5003.22.548.963903.6/6KV-1C6301×6303.22.753.580303.6/6KV-3C103×102.52.035.416203.6/6KV-3C163×162.52.238.420303.6/6KV-3C253×252.52.341.424703.6/6KV-3C353×352.52.444.229303.6/6KV-3C503×502.52.547.635103.6/6KV-3C703×702.52.751.943903.6/6KV-3C953×952.52.856.654703.6/6KV-3C1203×1202.53.060.464503.6/6KV-3C1503×1502.53.164.174903.6/6KV-3C1853×1852.53.368.388503.6/6KV-3C2403×2402.63.575.4110806/10kVPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/km6/10KV-1C161×163.41.622.57506/10KV-1C251×253.41.623.88906/10KV-1C351×353.41.725.210406/10KV-1C501×503.41.726.512006/10KV-1C701×703.41.828.514806/10KV-1C951×953.41.930.618106/10KV-1C1201×1203.41.932.221006/10KV-1C1501×1503.42.034.424706/10KV-1C1851×1853.42.136.929806/10KV-1C2401×2403.42.239.836506/10KV-1C3001×3003.42.342.443406/10KV-1C4001×4003.42.546.654806/10KV-1C5001×5003.42.649.564306/10KV-1C6301×6303.42.753.980406/10KV-3C163×163.42.342.523306/10KV-3C253×253.42.445.928406/10KV-3C353×353.42.548.733106/10KV-3C503×503.42.751.938906/10KV-3C703×703.42.856.448206/10KV-3C953×953.43.060.859006/10KV-3C1203×1203.43.164.568806/10KV-3C1503×1503.43.368.379606/10KV-3C1853×1853.43.472.893906/10KV-3C2403×2403.43.779.2115708.7/15kVPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/km8.7/15KV-1C251×254.51.726.210208.7/15KV-1C351×354.51.827.611708.7/15KV-1C501×504.51.828.913408.7/15KV-1C701×704.51.930.916308.7/15KV-1C951×954.52.033.420008.7/15KV-1C1201×1204.52.035.023008.7/15KV-1C1501×1504.52.137.327308.7/15KV-1C1851×1854.52.239.331808.7/15KV-1C2401×2404.52.342.238608.7/15KV-1C3001×3004.52.445.246008.7/15KV-1C4001×4004.52.548.856908.7/15KV-1C5001×5004.52.751.966808.7/15KV-1C6301×6304.52.856.783608.7/15KV-3C253×254.52.651.032808.7/15KV-3C353×354.52.753.837708.7/15KV-3C503×504.52.957.444308.7/15KV-3C703×704.53.061.553408.7/15KV-3C953×954.53.266.064608.7/15KV-3C1203×1204.53.369.674608.7/15KV-3C1503×1504.53.573.986408.7/15KV-3C1853×1854.53.678.0100408.7/15KV-3C2403×2404.53.984.412270
Other supplier products
|
|
|
Industrial Cables H05V-KApplication and DescriptionThese insulated wires are determined for installation to tde inside of apparatus as well as for ... |
|
|
|
F6 AICI NEK606 optical fibre cableApplications :These optical fibre cables are fire resistant,Website:, flame retardant, low smoke and halogen free... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9843ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
Type 210 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used for hand-held boring machines and drills.StandardsAS/NZS 1802:2003AS/NZS ... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (Single Core)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/AWA/PVC 600/1000V Clas... |
供应产品
Same products