1.9/3.3kV, 3.3/3.3kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power

1.9/3.3kV,Website:, 3.3/3.3kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control CablesApplication:These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.Standards:l BS 6883l IEC 60332-3A Flame retardantl IEC 60754-1; IEC 60754- 2 Corrosivityl IEC 61034-2 Smoke densityl Cold bend and impact (-40°C) (on request)l CSA C22.2 No. 38-95 (on request)Construction:l Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.l Insulation: HF-EPR GP5 according to BS 7655 1.2.l Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.l Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).l Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD
Temperature Range: -40℃ ~ +90℃Dimensions and Weight1.9/3.3kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×102.21.110.211.90.31.314.216.23981×162.21.211.413.10.31.315.417.64991×252.21.213.014.80.31.417.119.56751×352.21.314.115.90.31.418.220.67931×502.21.315.317.20.31.519.622.49701×702.21.417.219.20.31.621.724.612691×952.41.519.421.90.31.724.227.216231×1202.41.621.323.80.31.726.029.119831×1502.41.622.825.40.451.828.431.624231×1852.41.724.827.40.451.930.634.329171×2402.41.827.530.30.452.033.537.336541×3002.41.930.033.20.452.136.240.144281×4002.62.033.837.10.452.340.344.854161×5002.82.237.641.10.452.544.549.267261×6302.82.341.245.20.452.648.453.685623×102.21.520.422.90.31.725.128.210523×162.21.622.825.30.31.827.730.813573×252.21.826.629.30.452.032.636.320323×352.21.828.431.20.452.134.638.523823×502.21.931.234.40.452.237.641.629363×702.22.135.338.70.452.442.146.738773×952.42.340.244.10.452.647.452.149953×1202.42.444.048.10.452.751.456.761183×1502.42.647.651.80.452.955.360.872843×1852.42.751.756.40.453.059.665.787503×2402.43.057.762.90.453.366.272.6111183×3002.43.263.168.60.453.572.079.0135313.3/3.3kVConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×103.01.212.013.70.31.416.118.44831×163.01.213.014.70.31.417.119.45791×253.01.314.716.70.31.519.121.57741×353.01.315.617.60.31.519.922.88851×503.01.417.019.00.31.621.524.410821×703.01.518.921.00.31.623.426.413771×953.01.520.623.10.31.725.328.416991×1203.01.622.525.00.31.827.430.520811×1503.01.724.126.80.451.930.033.625501×1853.01.726.028.60.452.032.035.730321×2403.01.828.731.80.452.134.838.737801×3003.01.931.234.40.452.237.641.545631×4003.02.134.738.10.452.341.345.855141×5003.22.238.441.90.452.545.350.068071×6303.22.442.246.20.452.649.454.686913×103.01.724.126.70.451.929.933.614043×163.01.826.529.20.452.032.536.217383×253.01.930.133.20.452.136.340.223143×353.02.032.135.40.452.238.542.927013×503.02.134.938.30.452.341.546.032783×703.02.238.942.70.452.545.850.542263×953.02.442.946.90.452.750.255.552973×1203.02.546.750.90.452.854.259.764423×1503.02.750.354.90.453.058.264.276313×1853.02.854.459.20.453.262.768.991583×2403.03.160.465.70.453.469.176.011526
Other supplier products
|
|
|
N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605ApplicationsThese cables are used for the connection of mobile operatingequipment,Website:, in mine... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9844ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric in... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
H07RN8-F 450/750V Harmonized Rubber CablesApplicationsThese cables are designed for use in submersible pumpsand similar applications in water for i... |
供应产品
Same products