N2XH/ N2XCH

German Standard Industrial Cables N2XH/ N2XCHApplication and DescriptionN2XH power cables with enhanced resistance to fire are used mostly in areas where harm to human life or material must be prevented in case of fire such as industrial and public buildings,Website:, hotels, subway systems, hospitals etc. These cables are suitable for dry and wet environments as well as for outer application but are not suitable for direct burial into eartd or water.Standard and ApprovalVDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2Cable Construction1- Solid or stranded plain copper conductor- to DIN VDE 0295 cl. 1, cl. 2, BS 6360 cl. 1, cl. 2 and IEC 60228 cl 1, cl. 22- XLPE insulation type 2XI1, to HD 604 S1- Color coded to DIN VDE 0293-308- Green-yellow ground conductor (3 conductors and above)- Special LSOH filler- For N2XCH version witd concentric conductor:4-plain round copper wires and one or two transverse counter helix of copper tapes5-Thermoplastic polyolefin compound outer jacket type HM4, to HD 604 S1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Minimum bending radius: 12 x Ø- Flexing temperature: +5º C to +50º C- Fixed installation temperature: - 40º C to +90º C- Short circuit temperature: +250º C- Flame retardant: VDE 0482 part 266-2, DIN EN 50266-2 / IEC 60332-3- Low corrosiveness of combustion gases to DIN VDE 0482 part 267/ EN 50267-2-2/IEC 60754-2- Halogen-free to DIN VDE 0482 part 267 /EN 50267-2-1/IEC 60754-1- Smoke density to DIN VDE 0482 part 268/HD 606/BS 7622 PT1,PT2/EN 50268-1,-2/IEC 61034-1,-2- Insulation resistance: 20 MΩ x kmN2XCHCable ParameterN2XHAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPEINSULATION THICKNESS MMNOMINALOVERALL DIAMETER MMCOPPER WEIGHT KG / KMCABLE WEIGHT KG / KM121x4re0.77.538140101x6re0.78.05816081x10re0.78.89621061x16rm0.79.715427041x25rm0.910.624038021x35rm0.912.733649011x50rm1.014.14806202/01x70rm1.116.06728303/01x95rm1.117.991212004/01x120rm1.219.mcm1x150rm1.421.mcm1x185rm1.623.mcm1x240rm1.725.mcm1x300rm1.829.x400rm2.037.x500rm2.240.x1.5re0.711.129180142x2.5re0.711.948210122x4re0.712.777270102x6re0.713.711534082x10re0.715.319245062x16rm0.717.330760042x25rm0.921.1480980163x1.5re0.711.543179143x2.5re0.712.472225123x4re0.713.3115291103x6re0.714.417337183x10re0.716.128852363x16rm0.718.246177343x25rm0.922.3720120023x35rm0.924.x50rm1.026.x1.5re0.712.258208144x2.5re0.713.296265124x4re0.714.2154352104x6re0.715.423045484x10re0.717.538464764x16rm0.719.761496444x25rm0.924.5960144624x35rm0.927.x50sm1.029.6192025302/04x70sm1.132.9268834183/04x95sm1.137.5364845744/04x120sm1.241.mcm4x150sm1.446.mcm4x185sm1.649.mcm4x240sm1.754.x1.5re0.713.172243145x2.5re0.714.2120310125x4re0.715.3192413105x6re0.716.628853685x10re0.719.048077665x16rm0.721.4768116545x25rm0.928.x1.5re0.712.7101206147x2.5re0.713.5168287127x4re0.717.x1.5re0.713.x2.5re0.715.x1.5re0.715.x2.5re0.717.x4re0.721.x1.5re0.715.x2.5re0.717.x1.5re0.717.x2.5re0.721.x1.5re0.720.x2.5re0.724.x1.5re0.722.x2.5re0.724.x1.5re0.726.25761200N2XCHAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA# X MM²CONDUCTORTYPECONCENTRICCONDUCTOR CROSS SECTION MM²NOMINAL OVERALL DIAMETER MMCOPPER WEIGHT KG / KMCABLE WEIGHT KG / KM161x1.5re1.57.92798141x2.5re2.58.547122121x4.0re49.474163101x6.0re69.910820381x10re1011.318228661x16re1612.829741041x25rm2512.946560621x35rm3516.4654807162x1.5re1.x2.5re2.513.768273122x4.0re415.9110375102x6.0re617.116445882x10re1019.127461962x16rex25rm2525.1703127622x35rm3527.8980164212x50rm5031.x1.5re1.513.556252143x2.5re2.514.390305123x4.0re416.6147425103x6.0re617.724352883x10rex16re1622.158099943x25rm1627.8855144043x25rm2526.6938152423x35rm1629.x35rm3529.x50rm2532.x35sm3527.x35sm1626.x50sm2529.x50sm5030.6181922602/03x70sm3533.6226529322/03x70sm7034.1258430973/03x95sm5038.2315140043/03x95sm9539.4369243364/03x120sm7038.3403849254/03x120sm12041.x150sm7044.x150sm15045.x185smx240sm12054.x1.5re1.514.370284144x2.5re2.516.3136382124x4.0re417.8183494104x6.0rex10re1021.545786064x16re1623.8725119644x25rmx35rmx50rm2536.x35sm1629.x50sm2533.1204427302/04x70sm3538.4291137583/04x95sm5042.6404150544/04x120sm7043.x150sm7050.x185sm9555.x240sm12062.X1.5re2.514.5132.0320.0147X2.5re2.515.1200.0400.0127X4re418.1316.0580.01610X1.5re2.517.2177.0420.01410X2.5re418.9287.0550.01612X1.5re2.518.4204.0460.01412X2.5re419.2335.0610.01212X4re622.6528.0910.01616X1.5re420.0275.0686.01416X2.5re620.9450.0805.01621X1.5re622.6370.0766.01421X2.5re625.2572.01015.01624X1.5re623.2412.0800.01424X2.5re1026.1695.01100.01630X1.5re624.3500.0930.01430X2.5re1028.0842.01290.0
Other supplier products
|
|
|
German Standard Industrial Cables N2XH/ N2XCHApplication and DescriptionN2XH power cables with enhanced resistance to fire are used mostly in areas... |
|
|
|
150Ω profibus-1-pair-0-35mmPROFIBUS 1 Pair 0.35mm2 IEC60092ApplicationThese profibus cables are dedicated for fixed installation on board of ship,W... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed Power Cables (2-4 Cores) CU/XLPE/PVC 450/750V Class 2Application:The cables are mainly used in power... |
|
|
|
P15 UX 0.6/1kV NEK606 Earthing cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for earthing and bond... |
供应产品