N2XFGY/ NA2XFGY
German Standard Industrial Cables N2XFGY/ NA2XFGYApplication and DescriptionN2XFGY/ NA2XFGY cables are for lying in eartd,Website:, indoors, in ducts, in the open air, in the water, when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines ac-cording to Technical standards for electrical plants, equipments and installations in mines, as well as hori-zontal and vertical installation in places where there is a height difference in mines, including metdane holes.Standard and ApprovalIEC 60502-1, VDE 0276-603Cable Construction1- Stranded plain copper/aluminum conductor- to DIN VDE 0295 cl. 2, IEC 60228 cl. 22- Cross-linked polyetdylene 2XI1 acc. to VDE 0276-603- Color coded to DIN VDE 0293(HD 308)- Thermoplastic compound filler4- Flat steel wire with steel tape armour5- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 3500 volts- Minimum bending radius: 12 x Ø- Flexing temperature: -5º C to +70º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +250º C- Flame retardant: IEC 60332.1- Insulation resistance: >20 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPENOMINALOVERALL DIAMETER MMCOPPER WEIGHT KG / KMCOPPERCABLE WEIGHT KG / KMAL WEIGHT KG / KMAL CABLE WEIGHT KG / KM43x25rm25,x35rm28,x50sm28,/03x70sm31,/03x95sm35,/03x120sm38,mcm3x150sm42,mcm3x185sm46,mcm3x240sm51,x25+16rm26,x35+16rm29,x50+25sm31,/03x70+35sm35,/03x95+50sm38,/03x120+70sm42,mcm3X150+70sm47,mcm3X185+95sm51,mcm3X240+120sm58,x6rm18,x10rm20,x16rm23,x25rm28,x35rm30,x50sm31,/04x70sm35,/04x95sm38,/04x120sm41,mcm4x150sm47,mcm4x185sm51,mcm4x240sm58,x6rm19,x10rm21,x16rm25,x25rm30,
Other supplier products
|
|
S10 IYOI(c) 60 V NEK606 Armoured Tele cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for indoor tel... |
|
|
Armoured Cat 5e SF/UTP 24AWG IEC60092ApplicationThese Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, ca... |
|
|
German Standard Industrial Cables (N)YM(St)-JApplication and Description(N)YM(St)-J cables are made for an effective range of electromagnetic inter... |
|
|
300/500V PVC Insulated,Website:, PVC Sheathed Power Cables (2-5 Cores)05VV-K (CU/PVC/PVC 300/500V Class 5)BS Code: 3182Y/3183Y/3184Y/3185YHAR Code:... |
|
|
P30 RFOU-HCF / TFOU-HCF 6/10(12) kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smok... |
供应产品
Same products