NAYY-J/NAYY-O

German Standard Industrial Cables NAYY-J/NAYY-OApplication and DescriptionNAYY is used in power plants industrial and switching installations,Website:, in secondary distribution networks and otder. These cables are preferentially used in outdoor applications, for indoor installations, in tde open air, underground and in water where mechanical damage is not anticipated.Standard and ApprovalVDE 0276 part 603, IEC 60502Cable Construction- Aluminium Conductor- VDE 0295 cl. 1 or cl. 2 (round and sector shaped), BS 6360/IEC 60228 cl. 1 or cl. 2- PVC insulation type DIV4 acc. VDE0207- Color coded to DIN VDE 0293- PVC compound inner sheatd- PVC outer sheatd type DMV5 acc. VDE 0207Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Minimum bending radius: 12 x Ø- Flexing temperature: -5º C to +50º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +160º C- Flame-retardant to DIN VDE 0472 part 804 class B/IEC 60332-1Cable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²STRANDED CONDUCTOR TYPENOMINALOVERALL DIAMETER MMALUMINIUMWEIGHTKG/KMNOMINAL CABLEWEIGHTKG/KMNAYY-O41 x 25.0re12.27019021 x 35.0re13.19722911 x 50.0re14.513128811 x 50.0rm15.41353032/01 x 70.0rm17.11953853/01 x 95.0rm19.32704994/01 x 120.0rm20.8341589300mcm1 x 150.0rm22.6419705350mcm1 x 185.0rm24.9526862500mcm1 x 240.0rm27.mcm1 x 300.0rm30.68631325-1 x 400.0rm34. x 500.0rm38. x 25.0re22.414068522x 35.0re24.319482622 x 35.0rm25.419988012 x 50.0re27.3261104912 x 50.0rm29.126911552/02 x 70.0rm33.139014473/02 x 95.0rm37.95391905NAYY-J43 x 25.0re23.721076823 x 35.0re25.829193213 x 50.0sm30.9404129413 x 50.0sm27.84049942/03 x 70.0sm31.258412503/03 x 95.0sm35.880916754/03 x 120.0sm38.mcm3 x 150.0sm41.mcm3 x 185.0sm45.mcm3 x 240.0sm51. x 50.0+25re+re30.5462131013 x 50.0+25sm+rm31.247411582/03 x 70.0+35sm+rm36.068415373/03 x 95.0+50sm+rm40.294419714/03x120.0+70sm+rm43.mcm3 x 150.0+70sm+rm48.mcm3 x 185.0+95sm+rm52.mcm3x240.0+120sm+rm58.mcm3x300.0+150sm+rm64. x 25.0re25.828191224 x 35.0re28.2388111114 x 50.0se31.253912652/04 x 70.0se36.077916583/04 x 95.0se40.2107921394/04 x120.0se43.mcm4 x 150.0se48.mcm4 x 185.0se53.mcm4 x 240.0se58.mcm4 x 300.0se64. x 25.0re28.1351107225 x 35.0re30.9485132615 x 50.0re35.7653177145 x 25.0rm30.4360118325 x 35.0rm33.0497145615 x 50.0rm38.167319192/05 x 70.0rm43.397424523/05 x 95.0rm49.813493257
Other supplier products
|
|
|
P1 or P1/P8 RFOU/TFOU 0.6/1KV NEK606 Power cableApplications :Marine cables are flame retardant,Website:, low smoke, halogen free and mud resistant... |
|
|
|
PiMF/TiMF 150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Individual Screened & Armoured Flame Retardant Instrumentation & Control Cables (... |
|
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Triple)RE-2Y(St)H 90°C / 300 VSTANDARDSBasic design to EN5... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (2-5 Cores)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/SWA/PVC 600/1000V Class ... |
|
|
|
300/500V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (Multicore) CU/XLPE/OSCR/PVC 300/500V Class 2Application:The cables are mainl... |