XHHW-2, AL Armor, 600V Type MC

UL Industrial Cables XHHW-2,Website:, AL armor, 600V Type MCApplication and Description600 Volt Type MC Cable is for use in aerial installations, direct burial, metal racks, cable trays, troughs or continuous rigid cable supports. Listed by Underwriters Laboratories as Type MC, this cable is capable of operating continuously at a maximum conductor temperature of 90° C in wet or dry locations. For use in Class I Div. 2, Class II Div. 2, & Class III Div. 1, hazardous locations.Cable ConstructionConductorClass B compressed concentric stranded bare copper in accordance witd ASTM B3 and B8 and ICEAInsulationFlame-retardant and moisture resistant Cross-Linked Polyetdylene (FRXLPE).Ground WireClass B compressed concentric stranded bare copper in accordance witd ASTM B3 and B8.AssemblyThe insulated conductors will be cabled round witd fillers and witd a grounding conductor in one outer interstice and covered witd a binder tape.ArmorA single strip of interlocked aluminum tape.JacketFlame retardant, sun resistant PVC (CPE/LSOH is available upon request)Colorupon request, black is preferableTechnical Characteristics- UL 44 - Thermoset-Insulated Wires and Cables- UL 1569 - Metal-Clad Cables- IEEE 1202 - Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 Btu/hr)- ICEA T-29-520 - Vertical Cable Tray Flame Tests (210,000 Btu/hr)- ICEA S-95-658 (NEMA WC 70) construction requirementsCable ParameterAWGORKCMILCONDUCTORINCH/MMNOMINALINSULATIONTHICKNESSINCH/MMNOMINALINSULATIONDIAMETERINCH/MMGROUNDWIRESIZECOREDIAMETERINCH/MMARMORDIAMETERINCH/MMNOMINALJACKETTHICKNESSINCH/MMNOMINALOVERALLDIAMETERINCH/MMCABLEWEIGHTLBS/KFTKG/KM3 cores80.1393.530.0451.140.2325.89100.51012.950.72018.290.0501.270.82020.8340560360.1744.420.0451.140.2676.7880.58614.880.79620.220.0501.270.89622.7655081940.2215.610.0451.140.3147.9880.68517.400.89522.730.0501.270.99525..2777.040.0451.140.3709.4060.80820.521.01825.860.0501.271.11828..3228.180.0551.400.43511.0560.94824.081.15829.410.0501.271.25831./00.3629.190.0551.400.47512.0761.03426.261.24431.600.0501.271.34434./00.40510.290.0551.400.51813.1661.12728.631.33733.960.0501.271.43736./00.45411.530.0551.400.56714.4041.23331.321.44336.650.0501.271.54339./00.51012.950.0551.400.62315.8241.35434.391.66442.270.0601.521.78445..55814.170.0651.650.69117.5541.50138.131.81146.000.0601.521.93149..66116.790.0651.650.79420.1731.72343.762.03351.640.0601.522.15354..79020.070.0651.650.92323.4422.00250.852.31258.720.0751.912.46262..96824.590.0802.031.13128.7312.45562.362.76570.230.0751.912.91574. cores2500.55814.170.0651.650.69117.5541.67642.571.98650.440.0601.522.10653..66116.790.0651.650.79420.1731.92548.902.23556.770.0601.522.35559..79020.070.0651.650.92323.4422.24056.902.55064.770.0751.912.70068.
Other supplier products
|
|
|
3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1)Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath)ApplicationThes... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (2 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic d... |
|
|
|
Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, TPU Jacket 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for h... |
|
|
|
0.6/1KV SCP,Website:, SYPStandards:JISC 3410-1999IEC 60332-1CABLE CONSTRUCTIONConductorSBunched tinned annealed stranded copper, class 5 according ... |
供应产品
Same products