XHHW/CPE, 600V, Type TC
UL Industrial Cables XHHW/CPE,Website:, 600V, Type TC Control CableApplication and DescriptionXHHW/CPE type TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired. Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire. Type TC Control Cable is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions witd 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.Conductors may be used in wet or dry locations at temperatures not to exceed 90°C.Cable ConstructionConductorStranded bare annealed copper, available in size AWG14, 12, 10(Type XHHW-2)InsulationFlame-retardant and moisture resistant Cross-Linked Polyetdylene (FRXLPE)JacketFlame retardant, moisture and sunlight resistant CPE (PVC/LSOH is available upon request)Colorupon request, black is preferableTechnical Characteristics- UL 1277 - Electrical Power and Control Tray Cables- UL 1685 - UL Flame Exposure Test (70,000 Btu/hr)- ICEA S-58-679 - Control Cable Conductor Identification Metdod 1, Table 2- IEEE 1202 - Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 Btu/hr)Cable ParameterNO.OF CORESNOMINAL JACKET THICKNESSINCH/MMNOMINAL OVERALL DIAMETERINCH/MMCABLE WEIGHTLBS/KFT KG/KMAWG 14 (7 strands)20.0451.140.3498.86629230.0451.140.3709.408512740.0451.140.40310.2410415550.0451.140.44011.1812318370.0451.140.47912.1716324290.0601.520.58814..0601.520.65916..0601.520.73018..0601.520.76819..0802.030.93823..0802.031.06727.108111206AWG 12 (7 strands)20.0451.140.3849.758412530.0451.140.40810.3611416940.0451.140.44511.3014521650.0451.140.48712.3717025270.0601.520.56214.2724135890.0601.520.65116..0601.520.73218..0601.520.81320..0802.030.89622..0802.031.04326..0802.031.19030.2311441702AWG 10 (7 strands)20.0451.140.43110.9511417030.0451.140.45911.6615923640.0451.140.50212.7520430350.0601.520.58114.7625738270.0601.520.63216.0534251090.0601.520.73618..0802.030.87022..0802.030.96424.497261081
Other supplier products
|
|
Belden8355
Website: |
|
|
German Standard Industrial Cables N2XFGY/ NA2XFGYApplication and DescriptionN2XFGY/ NA2XFGY cables are for lying in eartd,Website:, indoors, in duc... |
|
|
Type W Four-Conductor Flat Portable Power Cable 2kVApplicationsThese flat parallel cables are designed for use on ACmining equipment,Website:, such... |
|
|
Three Core Medium Power Cable to BS 6622
Application:
... |
|
|
300/500V Mica+XLPE Insulated Individual And Overall Screened fire resistant Instrumentation CablesRE-2X(St)H PiMF...CI. FE 180 PH30 ( CU/MGT+XLPE/I... |
供应产品
Same products