Conductor Crosssectional Area

600/1000V XLPE Insulated,Website:, PVC Sheathed, Copper tape shield Power Cables (Single Core)CU/XLPE/CUTO/PVC/AWA/PVC 600/1000V Class 2Application:This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors.STANDARDS:Basic design adapted to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Overall Screen: Copper TapeInner sheath: PVC CompoundOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESMaximum conductor temperature: Max 90°C for XLPEMinimum bending radius: 12 x Overall Diameter (for 70mm2 to 1000mm2)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessDiameter Under ScreenDiameter Over Inner SheathArmour Wire DiameterNominal Overall DiameterApprox. Weightmm2No./mmmmmmmmmmmmmmkg/km1x7019/2.141.11.815.217.620.123.914001x9519/2.521.11.817.119.522.025.817001x12037/2.031.21.819.020.824.027.820001x15037/2.251.41.821.022.826.029.824001x18537/2.521.61.823.225.028.232.028001x24061/2.251.71.926.127.931.135.135001x30061/2.521.82.028.730.533.737.942001x40061/2.852.02.132.534.338.342.754001x50061/3.202.22.236.037.841.846.465001x630127/2.522.42.340.442.246.251.082001x800127/2.852.62.545.547.352.357.5104001x1000127/3.202.82.750.452.257.262.413000Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor cross- sectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable tray or Reference Method 13 [free air] )Reference Method 12 (free air)In single-way ductsLaid direct in ground2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.3 cables 3-phase a.c. trefoil touching2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.mm2AAAAAAAAAVoltage Drop (Per Amp Per Meter)Conductor crosssectional area2 cables d.c.2 cables singlephase a.c.3 or 4 cables three-phase a.c.2 cables singlephase a.c.3 or 4 cables, 3-phase a.c. touchingReference Method 1 & 11 (touching)Reference Method 1, 11 & 12 (in trefoil touching)Reference Method 1 & 11 (Flat touching)In ductsIn groundIn ductsIn ground123456789mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mrxzrxzrxz700.670.680.200.710.590.170.620.60.250.650.800.700.700.61950.490.510.1950.550.440.170.470.460.240.520.650.530.560.461200.390.410.1900.450.350.1650.390.380.240.440.550.430.480.371500.310.330.1850.380.290.1600.330.310.230.390.500.370.430.321850.250.270.1850.330.230.1600.280.260.230.340.450.310.390.272400.1950.210.1800.280.180.1550.240.210.220.300.400.260.350.233000.1550.170.1750.250.1450.1500.210.170.220.280.370.240.320.214000.1150.1450.1700.220.1250.1500.1950.1600.210.270.350.210.300.195000.0930.1250.1700.210.1050.1450.1800.1450.200.250.330.200.280.186300.0730.1050.1650.1950.0920.1450.1700.1350.1950.240.300.190.260.178000.0560.0900.1600.1900.0860.1400.1650.1300.1800.230.280.180.240.1610000.0450.0920.1550.1800.0800.1350.1550.1250.1700.210.260.170.220.15


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

German Standard Industrial Cables LiFY Application and DescriptionLiFY is highly flexible lead wire,Website:, it can be used as super flexible insu...
PiMF/TiMF 150/250V Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Individual Screened & Armoured Fire Resistant Instrumentation & Contr...
Type SHD-CGC Three-Conductor Round Portable Power Cable 2kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applications such as ...
VDE Industrial Cables H05V2V2-F/H05V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, office fo...
0.6/1 kV HEPR Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore)ApplicationThese cables are used for fixed...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes