.

Flame Retardant RS485 Databus Cables LSZH Sheath

Flame Retardant RS485 Databus Cables Application:Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.Standard:Basic design to EIA/TIA 485FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING60VCABLE CONSTRUCTION Multipair RS 485 Overall Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall screen: Aluminum/polyester tape with tinned copper drain wire. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Overall Double Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall screen: Aluminium/polyester tape+copper wire braid. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Individual & Overall screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Overall Screen: Copper wire braid. outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) Multipair RS 485 Overall Screened Databus Cable Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Foam PE or foam skin PE. Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Overall Screen: Copper wire braid. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -20°C - +90°CTemperature range during installation (mobile state): -5°C - +60°C Minimum bending radius: 8 x Overall DiameterElectrical PropertiesDielectric test1000 V r.m.s. for 5’ (core-core)1000 V r.m.s. for 5’ (core-screen)Impedance120Ωcapacitance45 nF/km conductor to conductor90 nF/km conductor to shieldCONSTRUCTION PARAMETERSMultipair RS 485 Overall Screened Databus Cable RE-02Y(St)H / RE-02YS(St)HNo.of pair xNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.02120.227/0.20.550.407.14240.227/0.20.550.408.36810.5016/0.20.550.404.63220.5016/0.20.550.408.26840.5016/0.20.550.409.811510.7524/0.20.550.405.14020.7524/0.20.550.409.18440.7524/0.20.550.4010.914411.0030/0.20.550.405.24921.0030/0.20.550.409.510541.0030/0.20.550.4011.2182Multipair RS 485 Overall Double Screened Databus Cable RE-02Y(St)CH / RE-02YS(St)CHNo.of pair xNominal  Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.53420.227/0.20.550.407.56740.227/0.20.550.408.89710.5016/0.20.550.405.14820.5016/0.20.550.408.79740.5016/0.20.550.4010.315010.7524/0.20.550.405.65720.7524/0.20.550.409.711640.7524/0.20.550.4011.418211.0030/0.20.550.405.76721.0030/0.20.550.4010.013841.0030/0.20.550.4011.8222Multipair RS 485 Individual & Overall screened Databus CableRE-02Y(St)H pimf / RE-02YS(St)H pimfNo.of pair xNominal  Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.43520.227/0.20.550.407.56940.227/0.20.550.408.810610.5016/0.20.550.405.04920.5016/0.20.550.408.710040.5016/0.20.550.4010.315910.7524/0.20.550.405.55820.7524/0.20.550.409.711940.7524/0.20.550.4011.217411.0030/0.20.550.405.66821.0030/0.20.550.4010.014241.0030/0.20.550.4011.8234Multipair RS 485 Overall Screened Databus CableRE-02YCH / RE-02YSCHNo.of pair xNominal  Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.33120.227/0.20.550.407.36140.227/0.20.550.408.59110.5016/0.20.550.404.94420.5016/0.20.550.408.59140.5016/0.20.550.4010.014210.7524/0.20.550.405.45320.7524/0.20.550.409.510940.7524/0.20.550.4011.217411.0030/0.20.550.405.56321.0030/0.20.550.409.813141.0030/0.20.550.4011.5213

在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore)RE-2Y(St)H 90°C / 500VSTANDARDSBasic design to EN 50288-7...
Harmonized Code Industrial Cables H05Z-U/H07Z-U/H07Z-RApplication and DescriptionThese cables are designed for tde internal wiring of switchboards ...
German Standard Industrial Cables LiFY Application and DescriptionLiFY is highly flexible lead wire,Website:, it can be used as super flexible insu...
VDE Standard Industrial Cables H07ZZ-FApplication and DescriptionThese LSZH cables are flexible,Website:, mainly used for mobile service, suitable ...
UL Industrial Cables THHN/THWN,Website:, 600V, Type TC control Cable Application and DescriptionType TC Control Cable is for use in industrial powe...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes