(N)SHOEU 0.6/1kV Flexible Cable VDE 0250 Part 812

(N)SHOEU 0.6/1kV Flexible cable VDE 0250 Part 812ApplicationsThese cables are designed for use in open cast miningfactories for laying of excavators and conveyor beltswith permanent movements between parts of thee quipment.These cables are used where the ascending pipe servesas earth conductor,Website:, for instance for submersible pumps.StandardsVDE 0250 Part 812ConstructionConductorsFlexible stranded copper conductor, class 5 according to DIN VDE 0295/IEC 60228.InsulationEPR.Earth Conductor (for –J type)Incorporatedas a fourth core or split into three in theouter interstices.InnerSheathEPR.Outer SheathCM type 5GM5.Dimensions and Weight(N)SHOEU-JNumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Inner SheathThickness of Outer SheathMinimum Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmmmmmmmkg/km3×1.00.600.81.29.29.61603×1.50.600.81.210.412.01803×2.50.700.81.211.312.92403×40.800.91.312.514.12953×60.801.01.413.915.53703×101.001.01.416.818.85703x50+3x25/31.101.42.531.534.525003x70+3x35/31.101.42.536.239.234003x95+3x50/31.201.72.842.045.044753x120+3x70/31.202.03.046.049.054004×1.50.600.81.210.713.02104×2.50.700.91.411.713.72604×40.800.91.413.715.73504×60.801.01.415.217.24854×101.001.01.619.021.06904×161.001.21.822.024.010904×251.001.32.226.529.516004×351.001.32.330.033.020904×501.101.52.634.538.527004×701.101.52.639.543.536204×951.201.72.845.049.047104×1201.202.03.351.055.06020(N)SHOEU-ONumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Inner SheathThickness of Outer SheathMinimum Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmmmmmmmkg/km5×1.50.600.81.212.014.02405×2.50.700.91.313.014.83055×40.800.91.414.817.04405×60.801.01.617.019.05805×101.001.01.620.023.08705×161.001.21.823.826.812805×251.001.32.329.532.519502×1.50.600.81.29.811.81557×1.50.600.91.413.014.62958×1.50.600.91.414.015.632010×1.50.601.01.615.517.539012×1.50.601.01.616.518.54452×2.50.700.81.210.812.81954×2.50.700.91.411.713.72907×2.50.700.91.415.017.04108×2.50.700.91.416.019.043010×2.50.701.01.618.020.552012×2.50.701.01.618.521.558018×2.50.701.01.621.524.583524×2.50.701.21.825.528.58952×40.800.91.212.013.625012×40.801.21.825.028.09901×161.00-1.49.611.22151×251.00-1.711.213.23251×351.00-1.812.614.64301×501.10-2.014.616.66101×701.10-2.216.618.68251×951.20-2.318.920.910701×1201.20-2.420.822.813001×1501.30-2.523.025.016101×1851.40-2.624.927.920001×2401.50-2.828.231.225001×3001.80-3.331.834.832003×2.50.700.81.211.312.92403×40.800.91.312.514.12953×60.801.01.413.915.53703×101.001.01.416.818.85703×161.001.01.619.022.07703×251.001.22.023.526.512003×351.101.32.227.530.515703×501.101.52.631.535.522003×701.101.52.636.040.029103×951.201.72.841.045.037803×1201.201.83.045.049.047003×1501.301.72.849.053.056503×1851.402.23.455.059.07050
Other supplier products
|
|
|
NF M 87-202 EIFAAPPLICATIONThese NF M 87-202 EIFA instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par... |
|
|
|
German Standard Industrial Cables LiFY Application and DescriptionLiFY is highly flexible lead wire,Website:, it can be used as super flexible insu... |
|
|
|
Type 1 1.1/1.1KV Individually Screened to AS/NZS 1972/1125/3808ApplicationsThese individually copper screened cables are used for wiring of machine... |
|
|
|
3.6/6KV,Website:, 6/10KV, 8.7/15KV, (FA-)SPYC, SPYCB, TPYC (FA-)SPYCY, SPYCBY, TPYCYStandards:JISC 3410-1999
IEC 60092-350
IEC 60092-35... |
|
|
|
Type 260 1.1 to 11KV AS/NZS 1802ApplicationsThese armoured cables are mainly used as feeder cables for power supply where mechanical protection and... |