Type 2S 1.1/1.1KV & 3.3/3.3KV Individually Screened

Type 2S 1.1/1.1KV & 3.3/3.3KV Individually ScreenedApplicationsThese individually copper screened cables are used for wiring of machines or between machines and equipment wherea rubber cable is desired. These cables are also used for longwall lighting circuits,Website:, and may contain pilot and controlcores or twisted pair and screened cores.StandardsAS/NZS 1972:2006AS/NZS 1125AS/NZS 3808ConstructionConductorsStranded copper conductor.InsulationEPR.FillingElastomer centre filler.Pilot/Control CoresEPR covered and composite screened flexible stranded tinned copper conductor.IndividualComposite Screen (earth conductor)Tinned annealed copper braiding interwove with polyester yarn.SheathHeavy duty CPE sheath.Dimensions and WeightNumber of CoreNominal Conductor AreaStrand SizeInsulation ThicknessCore screenPilot ConductorNominal Sheath ThicknessNominal Overall DiameterNominal WeightStrand SizeAreaof ScreenNumber of PilotsStrand SizeThickness of Coveringmm²No/mmmmmmmm²No/mmmmmmmmkg/100mType 2S 1.1/1kV Individually Screened31077/0.401.20.27.93––1.822.16941077/0.401.20.27.94––1.823.093216126/0.401.20.29.02––1.822.081316126/0.401.20.29.03––1.823.4100416126/0.401.20.29.04––1.826.813531077/0.401.20.27.9330/0.201.01.822.587216126/0.401.20.29.0230/0.201.01.822.788316126/0.401.20.29.0330/0.201.01.827.7130325209/0.401.40.211.3330/0.201.01.829.2165335285/0.401.40.212.4330/0.201.01.831.6200350380/0.401.60.2517.5330/0.201.01.936.1260Type 2S 1.1/1kV Individually and Collectively Screened301.530/0.251.00.314.0–––1.932.6170Type 2S 3.3/3.3Kv Individually Screened31077/0.403.00.211.3330/0.251.01.828.9130316126/0.403.00.212.4330/0.251.01.831.3160325209/0.403.00.213.6330/0.251.01.934.8210335285/0.403.00.215.3330/0.251.02.037.8250350380/0.403.00.217.0330/0.251.02.141.3305370203/0.673.00.330.5330/0.251.02.246.8415395259/0.673.00.330.5330/0.251.02.349./0.673.00.447.5330/0.251.02.555.0620
Other supplier products
|
|
|
P7 or P7/P14 BFOU 6/10kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke, halogen ... |
|
|
|
300/500V Mica+XLPE or SR Insulated & Overall screened Armoured fire resistant Instrumentation cablesRE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/L... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (Multicore)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/SWA/PVC 600/1000V Class ... |
|
|
|
Fire resistant Central Loose Tube Fiber Optic cables FR200P 05M2XSH-R (CU/MICA+XLPE/OS/LSZH 300/500V Class 2 )Application:These cables are characte... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (Multicore) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl... |