Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 8kV ICEA S-75-381
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Jacket, 25kV to ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×119580.2606.40.143.62.3760.×1/019480.2606.40.143.62.4562.×2/019380.2606.40.143.62.5464.×3/019280.2606.40.143.62.6567.×4/019180.2606.40.143.62.8171.×250371/080.2606.40.174.32.9775.×350372/080.2606.40.174.33.1880.×500374/080.2606.40.174.33.4587.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Other supplier products
|
|
German Standard Industrial Cables N2XCYApplication and DescriptionIn indoor installation,Website:, in cable ducts outdoor and underground for power... |
|
|
UL Industrial Cables RHH/RHW-2,Website:, 600V, Power Cable, CT RatedApplication and DescriptionType RHH or RHW-2 or USE-2 conductors are for use in... |
|
|
German Standard Industrial Cables NHXMH/(N)HXMH(St)Application and DescriptionNHXMH cable is halogen free intended for fixed installation in dry an... |
|
|
Flame Retardant CAT5e Data Cables Application:Cat5E is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable for basi... |
|
|
250V [FA-] MPY-S,Website:, MPYC-S, MPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annea... |
供应产品
Same products