Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 5kV ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Jacket, 15kV to ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeLNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/KCMIinchmminchmminchmmlbs/kftkg/kmA3×27680.1754.40.143.61.9048.×119580.1754.40.143.61.9950.×1/019480.1754.40.143.62.0752.×2/019380.1754.40.143.62.1654.×3/019280.1754.40.143.62.2757.×4/019180.1754.40.143.62.3960.×250371/080.1754.40.143.62.4863.×350372/080.1754.40.143.62.7068.×500374/080.1754.40.174.33.0878.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Other supplier products
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9732ApplicationsThese cables have individually screened pairs laid up. Each individually s... |
|
|
|
UL Industrial Cables XHHW/PVC,Website: TC Power CableApplication and DescriptionXHHW/PVC, type TC Power Cable is used to supply power to motors, or... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables... |
|
|
|
Harmonized Code Industrial Cables H05V2-U/H07V2-U Application and DescriptionThese cables are for fixed protected installation inside appliances an... |
|
|
|
Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 acco... |