Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 5kV ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Jacket, 15kV to ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeLNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/KCMIinchmminchmminchmmlbs/kftkg/kmA3×27680.1754.40.143.61.9048.×119580.1754.40.143.61.9950.×1/019480.1754.40.143.62.0752.×2/019380.1754.40.143.62.1654.×3/019280.1754.40.143.62.2757.×4/019180.1754.40.143.62.3960.×250371/080.1754.40.143.62.4863.×350372/080.1754.40.143.62.7068.×500374/080.1754.40.174.33.0878.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Other supplier products
|
|
|
German Standard Industrial Cables H03RT-HApplication and DescriptionThese cables are suitable for power connecting wire and complete lines between ... |
|
|
|
UL Industrial Cables THHN / THWN-2 / MTWApplication and DescriptionType THHN/THWN conductors are primarily used in conduit for services,Website:, f... |
|
|
|
(N)TSCGECWOEU Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of electrical equipment,Website:,... |
|
|
|
450/750V SR Insulated & Overall Screened fire resistant Control Cables (1-4 Cores & Multicores)(PH30/60)(CU/SR/OS/LSZH 450/750V Class 5)Application... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 8776,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
供应产品
Same products